1.Clinical application of platelet aggregation for white blood cell count
Enliang HU ; Yuan ZHAO ; Yan WANG ; Ailin FAN ; Shanluan ZHENG
International Journal of Laboratory Medicine 2016;37(6):749-750,753
Objective To analyze the cause of platelet aggregation in blood specimens ,so as to provide basis for reducing platelet aggregation ,and avoiding false positive of platelet count ,false report ,misdiagnosis and mistreatment .Methods The blood speci-mens which platelet was below 80 × 109 /L ,below 125 × 109 /L with histogram hinted platelet aggregation ,were smeared ,stained with Wright-Giemsa ,and observed by microscope for platelet morphological changes .The data between each groups were calculated and analyzed by statistical software SPSS version 18 .0 .Results A total of 184 cases of ethylenediaminetetraacetic acid dependent pseudothrombocytopenia(EDTA-PTCP) were found ,accounted for 0 .444 ‰ totally ,including 0 .244 ‰ of out-patients (101 cases) , 0 .159 ‰ of hospitalized patients (66 cases) ,and 0 .041 ‰ of health examination personnel (17 cases) .3 cases of multi-dependent pseudothrombocytopenia and 25 cases of pseudo platelet aggregation were found ,and accounted for 0 .007 ‰ and 0 .060 ‰ respec-tively .Conclusion The discovery of platelet aggregation which caused mainly by EDTA-PTCP ,still relies on microscopy ,and pseu-do platelet aggregation comes mainly from sampling ,so it needs to strengthen the skills training .
2.Clinical application and evaluation of Sysmex XE-5000 automated blood cell analyser for detecting nucleated red blood cells
Tian ZHENG ; Shanluan ZHENG ; Enliang HU ; Xiang CHENG
International Journal of Laboratory Medicine 2015;(18):2666-2668,2671
Objective To evaluate the performance of XE‐5000 automated blood cell analyser for detecting nucleated red blood cell (NRBC) in peripheral blood and investigate its clinical application value .Methods The intra‐assay imprecision ,carryover rate , and linear range of the analyser were evaluated .The absolute NRBC count and percentage of NRBC of 137 blood specimens (NRBC‐positive according to the DIFF channel of the analyser) were determined in the NRBC channel of the analyser ,and the percentage of NRBC of these blood specimens were determined by using microscope method as well .Differences between the two methods were analysed by using SPSS18 .0 statistic software .Results The intra‐assay imprecision of the analyser for detecting absolute NRBC count in specimens with high ,moderate ,and low Q‐flag values were 2 .10% ,3 .26% and 11 .62% ,respectively ,and the imprecision for detecting percentage of NRBC were 3 .79% ,5 .80% and 13 .33% ,respectively .The carryover rates of the analyser for detecting absolute NRBC count and percentage of NRBC were 0 .51% and 0 .26% ,respectively .At the range of (0~18)× 109/L ,the absolute NRBC count detected by using the analyser showed good linearity :Y=1 .048 6X+0 .189 6(r=0 .999 1) .There were no statistically significant differences between the analyser and microscope for detecting percentage of NRBC(P=0 .716) ,and showed good corre‐lation:Y=1 .150 2X+0 .626 1(r=0 .967 0) .Conclusion The XE‐5000 automated blood cell analyser could completely replace the traditional microscope for clinically classifying and counting NRBCs .
3.Unstable atlas fractures treated by minitype titanium plate fixation through transoral approach
Shijie ZHAO ; Renfu QUAN ; Xiaojun ZHAI ; Enliang CHEN ; Qiang LI ; Guanrong SUN ; Wenyue HU
Chinese Journal of Trauma 2017;33(3):241-246
Objective To investigate the effect of minitype titanium plate fixation through transoral approach in the treatment of unstable atlas fractures.Methods A retrospective case series study was made on 21 patients with unstable atlas fractures treated by minitype titanium plate fixation through transoral approach from June 2008 to June 2014.There were 15 males and 6 females,at age of (40.9 ± 10.6)years (range,21 to 57 years).Anterior 1/2 Jefferson fractures were seen in 12 patients and 1/2 ring Jefferson fractures in 9 patients.Preoperative visual analogue score (VAS) was 4-9 points [(7.6 ± 1.3) points].Before operation,degree of mobility of the cervical vertebra was (15.4 ± 3.9) °in bending,(10.8 ± 2.5) °in extending,(18.3 ± 3.1) ° in left-bending,(18.9 ± 2.7) ° in right-bending,(21.8 ± 5.8) °in left-rotation and (22.4 ± 4.6) ° in right-rotation.Operation time,intraoperative blood loss,VAS,cervical mobility and bone healing were detected after operation.Results Operation time was (86.3 ±25.3)m in,and intraoperative blood loss was (120.5 ± 33.3)ml.VAS was improved to 0-2 points [(1.6 ± 0.4) points] at postoperative 3 days (P < 0.05).All patients were followed up for 12 to 48 months[(23.7 ±5.9) months].VAS was improved to 0-2 points[(0.6 ± 0.1) points] at postoperative 3 months (P < 0.05).Degree of mobility of the cervical vertebra was improved significantly at postoperative 3 months,with the bending of(38.6 ± 4.5) °,extending of (39.3 ± 4.0) °,left-bending of (39.2 ± 4.0) °,right-bending of (39.2 ± 2.9) °,left-rotation of (66.8 ± 8.8) ° and right-rotation of (66.3 ± 9.2) ° (P < 0.05).Postoperatively,there were no surgical wound incision infections and vertebral artery or spinal injuries,Bone union was found in all patients,without the occurrence of implant loosening or breakage and the dysfunction of the cervical vertebra.Conclusion Minitype titanium plate fixation through transoral approach is associated with less trauma,high healing rate and preservation of the activity of cervical vertebra in the treatment of unstable atlas fractures.
4.Evaluation of automated digital cell morphology system for the detection of platelet clumps
Ailin FAN ; Lihua YANG ; Jiayun LIU ; Xinfeng ZHANG ; Enliang HU ; Jie FENG
Chinese Journal of Laboratory Medicine 2023;46(7):732-737
Objective:To evaluate the performance of the automated digital cell morphology instrument in detecting platelet (PLT) clumps.Methods:A total of 4271 blood samples whose PLT reached the reviewing rules of thrombocytopenia were selected from inpatients having blood analysis in Xijing Hospital from January 1 st to June 30 th, 2019, including 2 200 males and 2 071 females,with a median age of (35±7.03) years old. The smears for these cases were made, stained by Wright-Giemsa, and examined to capture PLT clumps by digital cell morphology system and manual microscope separately. The digital cell analysis system (hereinafter referred to as the instrument method) as an evaluation method and the microscope method as a reference method were used to calculate the positive rate of platelet clump detection and evaluate the comparison of two methods and bias assessments. The chi-square test was used to compare counting data rates. Results:Among 4, 271 samples reaching the reviewing rule of thrombocytopenia, 128 cases with platelet clumps were detected by manual microscope(initial) with a positive detection rate of 96.24%, and a total 133 of cases with PLT clumps were detected by microscope (initial+reconfirmation) with a positive detection rate of 100 %. Meanwhile, 129 cases with platelet clumps were detected by instrument method with a positive detection rate of 96.9%. There was no significant difference in terms of positive rate of PLT clumps detection between the instrumental method and the microscope method (initial) ( χ2 =0.115, P=0.73); the positive rate of clumps detection by the instrumental method was lower than microscope method (initial+reconfirmation), and the difference was statistically significant (χ 2 =4.061, P=0.04). For instrument method, the positive rate of PLT clumps detection by simultaneous observation of RBC analysis interface+PLT aggregation interface+WBC analysis interface was higher than only observation of PLT aggregation interface, and the difference was statistically significant (χ 2 =5.090, P=0.02). The average error of the deviation of PLT counting results before and after correction of the cases with PLT plumps missed by instrument method was significantly higher than microscope method (initial), and the difference was statistically significant (χ 2 =56.26, P<0.001). Conclusion:The automated digital cell morphology system has a good consistency with manual microscope(initial) in terms of the sensitivity of platelet clumps detection and can be used as a supplementary method for detecting platelet aggregation.
5. A multi-center research on the establishment and validation of autoverification rules for blood analysis
Wei XU ; Xiaoke HAO ; Wei CUI ; Hong JIANG ; Xuefeng WANG ; Chenxue QU ; Lei ZHENG ; Yandan DU ; Linlin QU ; Enliang HU ; Jianbiao WANG ; Zhigang MAO ; Lingling LIU ; Cuiling ZHENG ; Dehua SUN ; Chengwei PU ; Chunxi BAO ; Li LING ; Qiang LI ; Tan LI
Chinese Journal of Laboratory Medicine 2018;41(8):601-607
Objective:
To establish a set of rules for autoverification of blood analysis, in order to provide a way to validate autoverification rules for different analytical systems, which can ensure the accuracy of test results as well as shorten turnaround time (TAT) of test reports.
Methods:
A total of 34 629 EDTA-K2 anticoagulated blood samples were collected from multicenter cooperative units including the First Hospital of Jinlin University during January 2017 to November 2017. These samples included: 3 478 cases in Autoverification Establishment Group, including 288 cases for Delta check rules; 5 362 cases in Autoverification Validation Group, including 2 494 cases for Delta check; 25 789 cases in Clinical Application Trial Group. All these samples were analyzed for blood routine tests using Sysmex XN series automatic blood analyzers.Blood smears, staining and microscopic examination were done for each sample; then the clinical information, instrument parameters, test results and microscopic results were summarized; screening and determination of autoverification conditions including parameters and cutoff values were done using statistical analysis. The autoverification rules were input into Sysmex Laboman software and undergone stage Ⅰ validation using simulated data, and stage Ⅱ validation for post-analytical samples successively. True negative, false negative, true positive, false positive, autoverification pass rate and passing accuracy were calculated. Autoverification rules were applied to autoverification blood routine results and missed detection rates were validated, and also data of autoverification pass rate and TAT were obtained.
Results:
(1)The selected autoverification conditions and cutoff values included 43 rules involving WBC, RBC, PLT, Delta check and abnormal characteristics. (2)Validation of 3 190 cases in Autoverification Establishment Group showed the false negative rate was 1.94%(62/3 190)(