1.Detection of sensitization to HLA antigens after liver transplantation
Weijie ZHANG ; Dawei WANG ; Dunxiu CHEN
Chinese Journal of Organ Transplantation 2003;0(05):-
Objective To investigate the sensitization to HLA antigens and relationship between sensitization and allograft function after liver transplantation. Methods The panel reactive antibody (PRA) in serum was determined by using LAT ELISA kit in 15 recipients before and after liver transplantation. Results Moderate sensitization was detected in one of 15 cases before transplantation. The patient experienced one episode of mild rejection, which was reversed by treatment with Methylprednisolone. PRA in this patient maintained positive 3 months posttransplantation. The remaining 14 patients had negative PRA (
2.Antibody-mediated rejection in human cardiac allografts: histopathological and immunohistochemical study
Hui GUO ; Hongmin ZHOU ; Sheng CHANG ; Dunxiu CHENG ; Weijie ZHANG ; Zhonghua CHEN
Chinese Journal of Organ Transplantation 2012;33(7):417-421
Objective To observe the pathologic features on cardiac allograft and to test archived endomyocardial biopsy specimens for antibody-mediated rejection specific marker-C4d deposition and its characteristics by using immunoperoxidase (IP) techniques. Methods From January 2003 to December 2007,10 recipients underwent orthotopic cardiac transplantation and 17 specimens of endomyocardial biopsy were obtained either for a protocol basis (generally at 1 st month,3rd month,1st year and 2nd year post-transplant) and on immediate clinical indications.All specimens of endomyocardial biopsy were collected for histopathological examination and C4d immunohistochemical staining,simultaneously. All pathological diagnoses were done according to 2004 International Society for Heart and Lung Transplantation (ISHLT) recommendation working formulation and AMR Schema,and C4d staining intensity were graded and recorded as 0 to 3 +.Results Except 1 specimen unqualified,all 16 consecutive specimens of endomyocardial biopsy were qualified.There were 4 cases of acute T cell-mediated rejection (all graded 1 ),2 cases of Quilty lesion,and 7 cases of antibody-mediated rejection,who were documented according to ISHLT Schema and C4d deposition.Meanwhile,there were 6 cases showing evidence of antibody-mediated rejection without concurrent acute cellular rejection and only one case concordant with acute T cell-mediated rejection.One case of antibody-mediated rejection died 20 months posttransplantation due to combined transplant coronary artery disease (TCAD). The C4d in the cardiac allograft was deposited in microvasculature diffusively.Conclusion Antibody-mediated rejection is an important clinical entity following orthotopic heart transplantation and is difficult to diagnosis except to perform endomyoeardial biopsy.Immunoperoxidase staining for C4d is a sensitive and specific technique for detecting one marker of antibody-mediated rejection.
3.Application of FLOW-PRA detection in clinical organ transplantation
Wei HUANG ; Zhishui CHEN ; Weijie ZHANG ; Dunxiu CHENG ; Xing WANG ; Dawei WANG ; Ping ZHOU
Chinese Journal of Organ Transplantation 2010;31(3):173-176
Objective To apply flow cytometry-panel reactive antibody (FLOW-PRA) and compare the application of traditional (enzyme-linked imrnunosorbent assay) ELISA-PRA in clinical organ transplantarion,so as to evaluate the concordance,sensitivity,accuracy and practicability of FLOW-PRA.Methods PRA was detected in 212 serum samples from 185 patients awaiting organ transplantation using FLOW-PRA and ELISA-PRA.Results It took 1.5 h and 3 h for FLOW-PRA vs ELISA-PRA.Concordance correlation coefficient for the results of the two methods was 94% (class Ⅰ)and 89% (class Ⅱ),respectively.Of all sera,24.5% (in comparison to ELISA-PRA,P<0.005)were class I positive,18.4% (P<0.05) class Ⅱ positive by flow cytometry,and 17.9% and 14.6% by ELISA,respectively.The positive incidence in Flow group was higher than in ELISA group.Low titer of antibodies was detected positively only by flow eytometry,furthermore,the antigen specificity of PRA could only be discriminated by FLOW-PRA.Conclusion Flow cytometry is more sensitive and more accurate than ELISA in PRA detection.FLOW-PRA is easy to operate and time-effective,and suitable for clinical application.
4.The recombinant antibody HBsAg-Fab of hepatitis B virus to block hepatitis B reinfection after liver transplantation: a research in vitro
Tao PAN ; Li TANG ; Zhishui CHEN ; Dawei WANG ; Dunxiu CHENG ; Hui GUO
Chinese Journal of General Surgery 2001;0(08):-
Objective To study the effect of recombinant antibody HBsAg-Fab of hepatitis B virus(HBV) to block hepatitis B reinfection after liver transplantation.Methods The functional efficiency of antibody Fab in blocking hepatitis B reinfection after LT was analysis and studied by vitro infection test,complement toxicity assay and virus infection test,calculated the antibody absorption rate and cell death rate and cell infection rate,Results When the group with and the group without recombinant antibody Fab were compared,the antibody absorption rate,cell death rate and cell infection rate between the 2 groups showed sigificant defference(P