1.The evaluation of curative effect of radiofrequency thermocoagulation on semilunar ganglion of aged patients with recurrent trigeminal neuralgia.
Shenhong QU ; Xiping ZHU ; Tao WANG ; Dongyun LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2016;30(2):135-138
OBJECTIVE:
To investigate curative effect and importance of radiofrequency thermocoagulation onsemilunar ganglion of aged patients with recurrent trigeminal neuralgia.
METHOD:
112 cases with recurrent trigeminal neuralgia were performed with radiofrequency thermocoagulation on semilunar ganglion by puncture through skin under local anesthesia.
RESULT:
The maintaining effective duration in 112 cases was 7.3 ± 1.3 years after primary therapy. After the first thermocoagulation, 89.28% (100/112) patients got the relief from pain immediately, 8 (7.14%) cases also recieved the same effect after twice treatment. However two cases (2.6%) had no effects. The total effective rate was 98.21%. During five follow-up years, VAS scores, dose of carbamazepine and satisfaction were better than those before the treatment. The effective rate was still over 57.5% within three years after the treatment. The recurrent risk increased obviously from 40 months after the treatment by Kaplan-Meier method.
CONCLUSION
Semilunar ganglion of radiofrequency thermocoagulation was an ideal option for old-age patients with trigeminal neuralgia. It can be performed repeatedly.
Aged
;
Electrocoagulation
;
Humans
;
Recurrence
;
Treatment Outcome
;
Trigeminal Ganglion
;
surgery
;
Trigeminal Neuralgia
;
surgery
2.Evaluation on image quality and radiation dose of 640-slice CT coronary arteriography with AIDR3D reconstruction algorithm
Hesong SHEN ; Xinhua WANG ; Mingyue LUO ; Dan LIANG ; Shanshan ZHU ; Dongyun ZHU ; Caihong DU
Chongqing Medicine 2015;(10):1358-1361
Objective To investigate the image quality and radiation dose of 640-slice CT coronary arteriography(CTCA) with adaptive iterative dose reduction three-dimensional (AIDR3D)reconstrucction algoritym.Methods 640-slice CTCA with auto-matic exposure was performed on 84 consecutive patients.The original image data were reconstructed with AIDR3D and the filtered back-projection (FBP)algorithms at the image postprocessing workstation.Two experienced radiologists without knowing clinical information and reconstruction algorithms independently measured and calculated the image noise,signal-to-noise ratio and contrast-to-noise ratio with AIDR3D and FBP reconstruction algorithms.The qualitative image quality was assessed by using the 4-point scale.The radiation dose was calculated based on dose-length product exported on CT scanner.The quantitative and qualitative im-age quality with two kinds of reconstruction algorithm was analyzed statistically.Results The CTCA image noise was (27.20± 4.40)HU with AIDR3D and (60.00±12.40)HU with FBP,which with AIDR3D was decreased by 46.10% than that with FBP;the signal-to-noise ratio was 21.10 ± 5.10 with AIDR3D and 11.40 ± 2.80 with FBP,which with AIDR3D was increased by 84.70% than that with FBP;the contrast-to-noise ratio was 24.70±5.10 with AIDR3D and 13.50±3.20 with FBP,which with AIDR3D was raised by 82.20% than that with FBP,the differences in 3 indexes between the two kinds of reconstruction algorithm were statistically significant(P < 0.05 ).The CTCA qualitative image quality scores of proximal,middle and distal parts with AIDR3D were (3.90±0.30),(3.70±0.50)and (3.60±0.60)respectively,which all were higher than (2.60±0.60),(2.30± 0.60)and (2.10±0.70)with FBP respectively,the differences in 3 items between 2 kinds of algorithm had statistical significance (P <0.05).The total segments which could be used to diagnose the CTCA images with AIDR3D and FBP algorithms were 1 216 segments (96.50%)and 504 segments (40.00%),respectively,the difference had statistical significance(P <0.05).The mean ef-fective radiation dose was (2.10±1.00)mSv.Conclusion 640-slice CTCA with AIDR3D reconstruction algorithm not only signifi-cantly reduces the image noise than the conventional FBP algorithm,improves the quantitative and qualitative image quality,but also decreases the effective radiation dose.
3.Study on colorectal distension with partially automated and individualized insufflation of air for dual-energy CT colonography
Dan LIANG ; Hongmei GUO ; Chaijie DUAN ; Mingyue LUO ; Dongyun ZHU ; Jianping QIU ; Cai WENLI
Chongqing Medicine 2017;46(14):1897-1899,1903
Objective To study the compliance of examinees,and effectiveness of colorectal distension with partially automated and individualized insufflation of air for dual-energy CT colonography.Methods Forty-six healthy adult volunteers without history of conditions affecting gastrointestinal motor function were enrolled in this study.One day before CT examination,volunteers were asked to orally administered 60 mL 4% diatrizoate meglumine five times for fecal tagging.Air was insufflated by using an inflator in a partially automated and individualized manner.The volunteers were initially asked to assume the right lateral decubitus position,then slowly turn to the supine position.Insufflation rate began at 1.5 L/min,and decreased to 0.5 L/min at later stage.The necessity and volume of air insufflation were decided according to effectiveness of colorectal distension on CT scout images,self-reported sensation of volunteers,and intestinal pressure.Dual-energy CT scanning was performed,and dual-energy blended images were acquired.Compliance of volunteers was statistically analyzed.The effectiveness of colorectal segments distension was statistically analyzed by using Kruskal-Wallis H test.Results No abdominal pain,bloating,nausea or vomiting were noted in the 46 volunteers.All volunteers easily accepted colorectal insufflation of air,with grade 1 compliance.The effectiveness of colorectal distension of grades 1,2,3 and 4 were 0%,2.1%,5.1% and 92.8%,respectively.The difference of effectiveness of colorectal segments distension had no statistical significance(χ2=6.19,P=0.288).The effectiveness of insufflation was poor in 6 colorectal segments,including 2 in sigmoid colon and 2 in rectum.Effectiveness of insufflation was suboptimal in 14 colorectal segments,including 4 in descending colon,4 in sigmoid colon,and 3 in rectum.Conclusion Compliance of examinees with partially automated and individualized insufflation of air for dual-energy CT colonography is excellent,with good effectiveness of colorectal distension.
4. Effect of comprehensive feeding intervention on feeding intolerance of premature infants
Qinxia DU ; Lihua LUO ; Dongyun LIU ; Qian WU ; Xinyan ZHU ; Lei CHEN
Chinese Journal of Clinical Nutrition 2019;27(5):304-308
Objective:
To investigate the effect of comprehensive feeding intervention on feeding quality and weight gain of premature infants.
Methods:
Eighty-one premature infants admitted to the neonatal intensive care unit (NICU) of our hospital from September 2016 to December 2018 were selected and randomly divided into the intervention group (
5.Electronic cleaning of intestinal contents tagging by diatrizoate meglumine for single-source dual-energy CT colonography with sequential acquisitions and volume scanning
Dan LIANG ; Ling WANG ; Renbing ZHOU ; Xi ZHANG ; Yang LIU ; Junyan RONG ; Wenru LI ; Dongyun ZHU ; Wenli CAI ; Mingyue LUO
Chongqing Medicine 2018;47(10):1297-1300,1304
Objective To study the feasibility of applying electronic cleaning to intestinal contents tagging by diatrizoate meglumine for single-source dual-energy CT colonography with sequential acquisitions and volume scanning.Methods Twenty-four volunteers had fine effect of intestinal contents tagging by diatrizoate meglumine,good colorectal distension effect,fine image quality of dual-energy fusion colorectal images,and with informed consents were enrolled in this study.The single-source dual-energy CT colonography with sequential acquisitions and volume scanning was performed with an Acquilion ONE 320 row CT scanner,tube voltage 135 kVp/80 kVp.The intestinal contents conducted the dual-energy electronic cleaned based on decomposition of intestinal contents tagging by diatrizoate meglumine,soft tissue and air.The intestinal contents in one segment of intestinal lumen being 100% electronically cleaned served as the basic standard,the electronic cleaning effects were divided into the 5 grades:excellent,good,moderate,fair and poor;and grade 1-3 were effective fecal electronic cleaning.Results The grade 1,2,3,4,5 of electronic cleaning effect for solid as the main intestinal contents were 22.2%,53.3%,17.8%,6.7% and 0% respectively;and which of electronic cleaning effect for liquid as the main intestinal contents were 47.5%,47.5%,5.0%,0% and 0% respectively.The together total effective electronic cleaning of intestinal contents was 97.9% and the electronic cleaning effect was good.Conclusion Electronic cleaning could be used in the intestinal contents tagging by diatrizoate meglumine for single-source dual-energy CT colonography with sequential acquisitions and volume scanning.
6.Clinical application of SNP haplotype analysis in the preimplantation genetic diagnosis (PGD) of monogenic diseases
Jiang WANG ; Jiahong ZHU ; Dongyun LIU ; Shun XIONG ; Wei HAN ; Yao HE ; Guoning HUANG
Chinese Journal of Clinical Laboratory Science 2019;37(2):101-104
Objective:
To investigate the clinical application value of single nucleotide polymorphism (SNP) haplotype analysis in the preimplantation genetic diagnosis (PGD) of monogenic diseases.
Methods:
The whole genome amplification products of biopsied trophectoderm cells were analyzed by SNP haplotype analysis and verified by Sanger sequencing.
Results:
A total of 205 embryos were performed SNP haplotype analysis and Sanger sequencing. Among them, Sanger sequencing failed in 14.63% (30/205) of embryos, and SNP haplotype analysis failed in 0.98% (2/205) of embryos. The failure rate of the latter was significantly lower than that of the former (P<0.05). There were consistent results in 155 (75.61%) embryos, and inconsistent results in 18 (8.78%) embryos. Forty-five embryos in 41 cycles were performed embryo transplantation. The clinical pregnancy rate was 70.73% (29/41) and the implantation rate was 71.11% (32/45). The results of prenatal diagnosis of amniotic fluid during the second trimester of pregnancy were completely consistent with those of SNP haplotype analysis.
Conclusion
SNP haplotype analysis is accurate, and its failure rate is lower than that of Sanger sequencing. It can be effectively used in the PGD of clinical monogenic diseases.
7.Evaluation of three-dimensional CT reconstruction on the anatomic variation of inferior mesenteric artery and left colic artery.
Jiawei CAI ; Xiaofeng WEN ; Weixing LIN ; Zhen HE ; Dongyun ZHU ; Jianping QIU ; Decan KONG ; Xiaosheng HE ; Xiaowen HE ; Quan SHEN ; Xiaojian WU ; Ping LAN ; Zhiyang ZHOU ; Jia KE
Chinese Journal of Gastrointestinal Surgery 2017;20(11):1274-1278
OBJECTIVETo demonstrate the clinical applicability of three-dimensional CT angiography by evaluating the anatomic features and variation of inferior mesenteric artery(IMA) and left colic artery(LCA) in order to provide reference to vessel ligation strategy in laparoscopic rectal cancer surgery.
METHODSClinical and image data of 123 patients receiving abdominal multislice CT at The Sixth Affiliated Hospital from 2014 to 2015 were retrospectively analyzed. The images were 3D-reconstructed with computer 3D CT angiography and arterial enhancement phase images were chosen for analysis. Linear distances from IMA root to abdominal aortic bifurcation and from LCA at IMA root level to IMA root were measured. Branch types of IMA, coursing pattern of LCA, and association between LCA and inferior mesenteric vein (IMV) site were summarized.
RESULTSOf 123 cases, 80 were males and 43 were females, mean age was (46.8±16.6) years, body weight was (57.7±10.4) kg, and BMI was (21.3±3.6) kg/m. The average distance from IMA root to abdominal aortic bifurcation was (42.5±7.9) mm, and this distance was closely associated with body weight (OR=4.771, 95%CI: 1.398 to 16.283, P=0.013). Longer distance tended to appear in the heavier patients. LCA and sigmoid artery (SA) originating from same single IMA was found in 61(49.6%) cases; LCA and SA forking at same point in 35(28.5%) cases; LCA and SA coursing together and forking afterwards in 24(19.5%) cases, and LCA disappearing in 3(2.4%) cases. In 71(57.7%) patients, LCA ascended medial to the lateral border of left kidney, while in 16(13.0%) patients, LCA arranged below the inferior border of left kidney. When the LCA site was higher and the distance from LCA to IMA root was closer [distance from LCA to IMA root level was (24.2±9.9) mm, (30.0±15.2) mm and (66.6±12.3) mm, F=83.2, P<0.001]. At the level of IMA root, LCA located medial to IMV in 21(17.1%) cases, located just lateral to IMV in 54(43.9%) cases, and located lateral and ascended far away from IMV in 48(39.0%) cases.
CONCLUSION3D-CT angiography is non-invasive, efficient and accurate in evaluating coursing features and variation of IMA and its branches, which can provide important reference to the surgeons, promising laparoscopic surgery smooth and safe.
8.Equisetin is an anti-obesity candidate through targeting 11β-HSD1.
Zhenlu XU ; Dongyun LIU ; Dong LIU ; Xue REN ; Haibo LIU ; Guihong QI ; Yue ZHOU ; Chongming WU ; Kui ZHU ; Zhongmei ZOU ; Jing YUAN ; Wenhan LIN ; Peng GUO
Acta Pharmaceutica Sinica B 2022;12(5):2358-2373
Obesity is increasingly prevalent globally, searching for therapeutic agents acting on adipose tissue is of great importance. Equisetin (EQST), a meroterpenoid isolated from a marine sponge-derived fungus, has been reported to display antibacterial and antiviral activities. Here, we revealed that EQST displayed anti-obesity effects acting on adipose tissue through inhibiting adipogenesis in vitro and attenuating HFD-induced obesity in mice, doing so without affecting food intake, blood pressure or heart rate. We demonstrated that EQST inhibited the enzyme activity of 11β-hydroxysteroid dehydrogenase type 1 (11β-HSD1), a therapeutic target of obesity in adipose tissue. Anti-obesity properties of EQST were all offset by applying excessive 11β-HSD1's substrates and 11β-HSD1 inhibition through knockdown in vitro or 11β-HSD1 knockout in vivo. In the 11β-HSD1 bypass model constructed by adding excess 11β-HSD1 products, EQST's anti-obesity effects disappeared. Furthermore, EQST directly bond to 11β-HSD1 protein and presented remarkable better intensity on 11β-HSD1 inhibition and better efficacy on anti-obesity than known 11β-HSD1 inhibitor. Therefore, EQST can be developed into anti-obesity candidate compound, and this study may provide more clues for developing higher effective 11β-HSD1 inhibitors.