1.Dynamic changes of five constituents in Ligustri lucidi Fructus at five picking time
Fucheng WANG ; Donghan JI ; Chengwu FANG ; Daofeng GONG ; Chengkai XIA
Chinese Traditional Patent Medicine 2017;39(5):1011-1014
AIM To analyze the dynamic changes of five constituents in Ligustri lucidi Fructus at five picking time (August,September,October,November,December).METHODS The HPLC analysis of Ligustri lucidi Fructus ethanol extract was performed on a 25 ℃ thermostatic Aglient Zorbax SB-C1s column (4.6 mm ×250 mm,5 μm),with the mobile phase comprising of acetonitrile-0.1% phosphoric acid flowing at 1 mL/min in a gradient elution manner,and the detection wavelength was set at 224 nm.RESULTS Salidroside,tyrosol,luteolin-7-O-glucoside,ligustroflavone and specnuezhenide showed good linear relationships within their own ranges (r >0.999 0),whose average recoveries were 99.56%-100.30% with the RSDs of 0.89%-1.23%.The contents of various constituents (except for tyrosol) were the highest in samples picked up in September,followed by those picked up in October.CONCLUSION The suitable picking time of Ligustri lucidi Fructus is September and October.
2.Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size.
Chang Yeol LEE ; Kihong SON ; Sang Hun SHIN ; Seungwoo PARK ; Donghan LEE ; Haijo JUNG ; Munsik CHOI ; Won Young OH ; Kum Bae KIM ; Gwang Mo YANG ; Young Hoon JI
Korean Journal of Medical Physics 2011;22(1):3-11
The purpose of this study was to evaluate feasibility of Vertical Multileaf Collimator for determination of irradiation size using Vertical Multileaf Collimator and lead block to determine 4 different irradiation shape in case of Co-60 gamma-ray and 6 MV X-ray. We chose ion chamber, glass dosimeter and EBT chromic film to compare with Vertical Multileaf Collimator results and lead block results. In case of Co-60 gamma-ray and 6 MV X-ray, the central axis point dose normalized at reference field of lead block with ion chamber results for Vertical Multileaf Collimator were estimated higher than lead block about 5.1%, 4.2%. In case of Co-60 gamma-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 2.2%, 7.8%, 7.2%, 4.0% for reference, circle, triangle, cross field, respectively. In case of 6 MV X-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 6.7%, 6.2%, 3.8%, 6.2% for reference, circle, triangle, cross field, respectively. The results of EBT chromic film, Vertical Multileaf Collimator of penumbra size for all irradiation shape was smaller than lead block of those size that 2.0~3.5 mm for Co-60 gamma-ray, 0.5~1.0 mm for 6 MV X-ray. The results from this study, radiation treatment volume that results in shielding block can be minimized. In addition, during radiation treatment for 2, 3-dimensional radiation therapy using a Vertical Multileaf Collimator of this survey can be used to determine variety of irradiation fields.
Axis, Cervical Vertebra
;
Feasibility Studies
;
Glass