1.Expression of caspase-9 affected by AG on retina of rats with chronic IOP elevation
Qing-Zhu, NIE ; Qian, SHA ; Ying-Shuang, WANG ; Dong-Mei, GUI ; Zhi-Li, LIU ; Dian-Wen, GAO
International Eye Science 2008;8(7):1299-1303
AIM: To study caspase-9 expression on rat retina in the process of chronic elevation of IOP and the changes with the application of amino guanidine (AG), thus to investigate potential protective function of AG to rat retina with chronic elevation of IOP.METHODS: Immunohistochemistry, RT-PCR and Western blot were used to observe retinal morphology and expression of caspase-9 at different time points of rat with chronic IOP elevation, both affected or not affected by the application of AG.RESULTS: Compared with control group, as time passed retina of experimental group gradually had detectable morphological changes. On 21st day of chronic IOP elevation, retinas became thinner and the quantity of retinal ganglion cells (RGCs) decreased; caspase-9 expression increased, consistent with the morphological changes. The group using AG presented relatively smaller morphology changes and less expression of caspase-9.CONCLUSION: Apoptosis-related gene caspase-9 played a part in the process of chronic IOP elevation; AG protects retina by down-regulating expression of caspase-9.
2.The photodynamic effects of a novel photosensitizer ZnPcS4-BSA on human U251 glioma cells in vitro
Dian-Shuang XU ; Yi-Quan KE ; Xiao-Dan JIANG ; Ying-Qian CAI ; Yi-Ru PENG ; Ying-Xin LI
Chinese Journal of Neuromedicine 2012;11(2):114-120
Objective To report the phototoxicity effects of a novel photosensitizer ZnPcS4-BSA on photodynamic therapy (PDT) towards human U251 glioma cells in vitro. Methods The cellular uptake of ZnPcS4-BSA by U251 glioma cells was quantified by UV-spectra to determine the optimal incubation time. Human U251 glioma cells were incubated with ZnPcS4-BSA of various concentrations and received laser irradiation of different energy densities. Cell survival rates were measured by CCK-8 assay.Flow cytometer was used to detect apoptosis.Gene expressions of vascular endothelial growth factor (VEGF) were detected by Real-Time PCR in the U251 cells after PDT and β-actin was used as an internal standard. The normal U251 cells severed as controls. Results The uptake of ZnPcS4-BSA by U251 glioma cells reached the maximum after incubation for 4 hours.ZnPcS4-BSA of different concentrations without laser irradiation had no significant effects on cell survival rates (P>0.05).Without ZnPcS4-BSA incubation,compared with 0,25,50,100,200 J/cm2 groups, the cell survival rate of the 400 J/cm2 group was significantly lower (P<0.05), whereas no significant difference was found between any other two groups. When the U251 glioma cells incubated with 30 μ mol/L ZnPcS4-BSA for 4 hours underwent laser irradiations of 25,50,100,200 J/cm2,the cellular survival rates significantly decreased with the increased energy densities (P<0.05). When the U251 glioma cells incubated with ZnPcS4-BSA of 20,40,60,80,100 μ mol/L for 4 hours underwent laser irradiation of 200 J/cm2, the cellular inhibition rates significantly increased with the increased concentrations (P <0.05). Compared with controls, the cellular apoptosis and VEGF expression significantly increased in the U251 glioma cells incubated with ZnPcS4-BSA of 20 μmol/L after laser irradiation of 100 J/cm2 (P<0.05). Conclusion The novel ZnPcS4-BSA is a good photosensitizer for PDT towards U251 glioma cells,because the ZnPcS4-BSA-mediated PDT can induce effective apoptosis of the targeted cells.
3.Absorption and excretion of fluoride and aluminum after drinking brick tea in healthy adults
Qing-bin, LIU ; Hai-rong, LI ; Yu-hua, WANG ; Wu-yi, WANG ; Xiao-bo, LIU ; Ge, WANG ; Shu-cai, TIAN ; Dian-shuang, YING ; bing, YU ; Li-zhen, WANG ; Fu-jian, FENG
Chinese Journal of Endemiology 2011;30(2):134-136
Objective To observe the absorption, excretion and retention of fluoride and aluminum after drinking brick tea in healthy adults. Methods The study was conducted in ten healthy volunteers by drinking brick tea solution in which the fluoride and aluminum concentrations were 5.97, 7.53 mg/L, respectively. The concentrations of fluoride and aluminum were determined in serum samples collected before and at 0.5,1.0,2.0,3.0,and 24.0 h, and in urine samples collected before and during the periods 1.0,2.0,4.0, > 4.0 - < 24.0 h and 24 h after drinking brick tea solution by ion-selective electrode, inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma atomic mess spectrometry. The total amounts of intake and excretion of fluoride and aluminum in healthy volunteers during 24.0 h were calculated from their corresponding fluoride and aluminum ingesting from brick tea and excreting from urine. Results Before and during the periods 1.0,2.0,4.0,> 4.0 - < 24.0 h and 24.0 h after drinking brick tea solution, the urinary fluoride concentrations were (0.50 ±0.14), (2.14 ± 0.90), (1.57 ± 0.93), (2.43 ± 1.49), (1.91 ± 0.69), (0.58 ± 0.20)mg/L, respectively, and the aluminum concentrations in the urine samples were (0.35 ± 0.15), (0.65 ± 0.37), (0.50 ± 0.25), (0.52 ± 0.21 ),(0.50 ± 0.23), (0,46 ± 0.27)mg/L, respectively; the 24.0 h excreting rates of fluoride and aluminum from urine were 52.90%(4.64/8.77) and 12.38% (1.37/11.07), respectively. The fluoride concentrations in serum samples collected before and at 0.5,1.0,2.0,3.0,24.0 h after drinking brick tea solution were (0.06 ± 0.02), (0.14 ± 0.01 ), (0.21 ±0.04), (0.17 ± 0.04), (0.10 ± 0.03), (0.04 ± 0.01 )mg/L, respectively, and aluminum in those were (0.30 ± 0.05),(0.27 ± 0.01 ), (0.30 ± 0.12), (0.34 ± 0.19), (0.30 ± 0.10), (0.27 ± 0.09)mg/L, respectively. Conclusions Fluoride in brick tea is easyly to be absorbed and excreted through kidney, and the kidney excretory capacity of aluminum in brick tea is limited. Levels of fluoride and aluminum in urine could be taken as the indicators for monitoring the prevalent extent and evaluating preventive experiment's effect on the brick tea fluoride-aluminum toxicity; and fasting serum fluoride and aluminum levels could be taken as indicators for estimating the toxic condition of the brick tea fluoride-aluminum toxicity.
4.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve