1.Different frequencies of B lymphocytes committed to produce anti-thyrotropin receptor antibodies in patients at different clinical stages of Graves' disease
Weiguo JIA ; Decai CHEN ; Zhenmei AN ; Songquan WEI
Immunological Journal 2002;(1):1-5
Objective To investigate the relationship between the TRAb-producing cell precursors and different clinical stages of Graves' disease.Methods Peripheral lymphocytes were infected with Epstein-Barr virus,a kind of lymphocyte precursor stimulator,and were stimulated to produce TRAb.Results Of the total wells containing Ig-producing B cell precursors,there were 34.6% and 29.1% from 2 untreated patients,30% from 1 relapsing patient and only 1.3% and 3.8% from 2 healthy controls that secreted TRAb,respectively.As for the wells containing B cell precursors from 2 remission patients with undetectable TRAb in circulation,the percentage (10.7%) of TRAb-containing wells from one was higher than that from the other (5.3%).And the latter had similar percentage of TRAb-positive wells with the controls.The isotype of TRAb in supernatants of our EBV-transformed B lymphocytes was predominantly IgM.Conclusion The frequencies of TRAb-specific precursors were different at three distinct clinical stages of the disease.
2.The heritability of Graves′ disease and its clinical significance
Decai CHEN ; Weiguo JIA ; Xia CHEN
Chinese Journal of Endocrinology and Metabolism 1986;0(04):-
Objective To investigate the heritability of Graves′ disease (GD) and to discuss its clinical significance. Methods The heritability of GD was calculated using Falconer′s formula and by investigating the GD numbers of 1968 first relatives of 526 established GD patients. Results The heritability of GD was 45%, appearantlymuchlowerthanthoseofprevious reports in China. Conclusion The onset of GD is affected by both inheritant and environmental factors, the latter seems to be predominant over the former.
3.Atlanto-axial pedicle screw internal fixation to reconstruct upper cervical spine instability
Fei YANG ; Yonggang WU ; Min ZHAO ; Weidou JIA ; Decai YUN ; Jianhua WANG
Chinese Journal of Postgraduates of Medicine 2010;33(29):34-37
Objective To explore the clinical effect of the atlanto-axial pedicle screw internal fixation to reconstruct upper cervical spine instability. Methods Using atlanto-axial pedicle screw and internal fixation system combined with autogenous iliac bone graft to treat 21 patients with upper cervical spine instability. Type Ⅱ odontoid process old fracture was 13 patients, odontoid process nonunion was 5 patients, injury of the transverse ligament was 3 patients. They were placed in 84 atlanto-axial pedicle screws, autogenous bones were placed in the posterior arch of atlas and axis to fusion, so that atlanto-axial complex got stabilized. Results The left lateral cortical bone of atlas vertebral pedicle was broken by screws in 2 patients, but the spinal cord and vertebral artery was intact. X-ray film showed the atlas and the fracture of dens of axis was completely replaced in all patients. The position of screw and vertebral artery or spinal cord was good in CT image. According to JOA score standard, 15 cases of all were excellent, 3 cases were good,2 cases were common,1 case was bad, and the rate of excellent and good was 85.71%(18/21).Seventeen cases were followed up for 12-26 (12.83 ± 4.23) months, all patients had acquired bone fusion and found no screw and plate fracture. Conclusions Atlanto-axial pedicle screw combined with screw-plate system fixation to treat upper cervical spine instability, can significantly enhance the biomechanical stability of the atlanto-axial interbody, bone grafting fusion rate is higher, the application value of the atlanto-axialfusion is higher.
4.Combination of four medicines in treating postoperative complications of Ring mixed hemorrhoids
Jianrong CAI ; Fengqun ZHENG ; Shichang YU ; Decai JIA ; Guoqing REN ; Haili BAI
International Journal of Surgery 2010;37(6):375-377
Objective To eveluate the clinical curative effects of combination of Ma Yinglong She Xiang Zhi Chuang Gao,Jin Xuan Zhi Ke Xun Xi Xan,Diosmin,Macrogol 4000 powder in treating postoperative complications of ring mixed hemorrhoids.Methods Ninty cases of postoperative ring mixed hemorrhoids patients were divided into two groups randomly from January 2008 to June 2009.Experimental group:From the first day on Jin Xuan Zhi Ke Xun Xi San 55 g and the 1000 mL boiling water were added flushing,and Maying Long She Xiang Zhi Chuang Gao 2.5 g,2 times daily.The Macrogol 4000 powder 10 g and water 200 mL were admistrated orally,Diosmin 1.0 g orally,2 times daily.Oral administration of two kinds of medications was done each two hours.Control group:Using 1:100 Sterile warm salt water hip bath,and Ma Yinglong she xiang zhi chuang gao 2.5 g,2 times daily;Phenolphthalein tablets 100 mg orally,2 times daily.Results The experimental group surpassed the control group in the anus ache,the hemorrhage,edema (P<0.05).The heal time reduced obviously(P<0.01).Conclusion To combination of Ma Yinglong She Xiang Zhi Chuang Gao,Jin Xuan Zhi Ke Xun Xi San,Diosmin,Macrogol 4000 powder has the distinct improvement in the anus ache,the hemorrhage,dropsy of ring mixed hemorrhoids and reduces the injured area heal time obviously.
5.Individual protocol and clinical application of pedicle screw and plate internal fixation for the treatment of upper cervical disorders
Weidou JIA ; Guiyou BAI ; Fei YANG ; Bogui YANG ; Tiegang ZHENG ; Yingjie XU ; Decai YUN ; Hua SUN
Chinese Journal of Tissue Engineering Research 2010;14(4):752-756
BACKGROUND: The treatment of upper cervical spine disorders through a posterior pedicle fixation approach have been carried out in some domestic large hospitals, but this surgery is still considered as a difficulty of cervical spine surgery. In order to minimize the risk of surgery, the authors designed a program of individual operations, and combined with self-developed pedicle locating and directing speculum to determine precise intraoperative position of pedicle screws, and no report is found by searching related database in China.OBJECTIVE: To improve the one-time success rate of internal fixation screws, to investigate the biomechanical effect of the implant, to formulate a simple, practical, individual protocol for atiantoaxial pedicle screw-plate system based on related data. METHODS: A total of 31 patients were recruited from Department of Orthopaedics in the 251 Hospital of Chinese PLA, between January 2002 and September 2006. Under the guidance of self-made atlantoaxial locating and directing speculum, the entrance point and angle for screw insertion, as well as screw diameter and length were determined according to the results of X-ray and CT measurement. Atlas pedicle screw was inserted at left (19.93±1.32) mm, and right (19.16±1.3) mm; Atlas pedicle screw insertion angle to inside was left (23.72±2.09)°, and right (23.35±1.91)°; Atlas pedicle screw insertion angle to side of head was (9.00±1.20)°. Axis pedicle screw was inserted at left (13.14±0.82) mm, and right (13.85±0.79) mm; Axis pedicle screw insertion angle to inside was left (24.52±1.26)°, and right (20.42±1.42)°; Axis pedicle screw insertion angle to side of head was (25.00±3.00)°.RESULTS AND CONCLUSION: ①Totally 124 pedicle screws were implanted into 31 patients, and 122 screws were of one-time success. The precision rate was 98.39%. Two screws were secondly inserted because of cutting lateral cortical bone of pedicle for deviation of inward angle. ②Occipital neuralgia was found in 2 cases postoperatively and cured after one month of treatment;screws penetrated atlas left vertebral lateral wall in 2 cases, no spinal or vertebral artery injury was found. ③Radiographs showed that atlas was completely reduced in all patients, and apposition of dentoid process of axis fracture was good. CT films showed the screws a good location to the vertebrarterial spinal cord. ④The follow-up visit was averaged of 10.5 months. Bony fusion was found in all patients. No screw-plate breakage was found. No inflammatory or rejection reactions occurred.⑤By JOA scale, there were 16 cases of excellent, 12 cases of good, 2 cases of fine, and 1 case of poor. The excellent and good rate was 90%. It is suggested that the success rate of atlantoaxial pedicle screw-plate mplantation can be improved through a biomechanical angle.