1.Actions of Immature Orange Fruit and Dried Tangerine Peel on the Tension of Isolated Aortic Muscle Strips
Hongfang LI ; Danming LI ; Songyi QU
Chinese Traditional Patent Medicine 1992;0(09):-
Objective: To study the effects of immature orange fruit(IOF) and dried tangerine peel(DTP) on the resting tension of isolated aortic muscle strips in rabbits and their mechanisms. Methods: The organ-bath was used to observe the response of aortic strip to IOF and DTP. Results: IOF and DTP dose-dependently increased the tension of aortic strip, and the action of IOF was more significant than that of the same concentration DTP. 10 -7 mol/L phentolamine, 10 -5 mol/L verapamil or incubation with Ca 2+ -free Krebs solution could block the effects of IOF and DTP partly, but 10 -6 mol/L diphenhydramine could not. In endothelium-removed aortic strips, the effects of IOF and DTP decreased after treatment with 10 -7 mol/L atropine. Conclusions: IOF and DTP can contract vascular smooth muscle, which probably contribute to ? adrenergic receptor, cholinergic M receptor on membrane of vascular smooth muscle partly, and is dependent Ca 2+ influx through verapamil-sensitive Ca 2+ channels, but is not related to H 1 histamine receptor.
2.Observe the Relativity between Thyroid Gland Hormone and Plasm BNP Level and TCM Differentiation Types of Senile Patients of Congestive Heart Failure
Danming LI ; Lanying JIANG ; Zhongyin FU
Journal of Zhejiang Chinese Medical University 2006;0(05):-
[Objective]To observe the relativity between congestive heart failure(CHF) differentiation types of TCM and thyroid gland hormone,BNP and heart function parameters.[Method] Divide CHF patients into 4 groups,measure their heart function parameters,BNP and thyroid hormone,compare it to that of control group(21 cases).[Result] In CHF combined with blood stasis group,T3 level is much more reduced than that of control group and groups of heart Qi deficiency and combination of Yin deficiency(P
3.The research of different MRI-CT image registration for the stability of radiotherapeutic target delineation on gliomas after surgery
Danming LI ; Xixu ZHU ; Xinhu WU
China Oncology 1998;0(01):-
Background and purpose:Accurate target delineation in IMRT setting has been a challenge for post-operative gliomas.The fusion technology with MR+CT image registration could improve the accuracy of target delineation,but there are no reports as to whether this technique could increase the stability of target delineation.This study was to investigate the accuracy of different fusion technologies with MRI+CT image registration so it could improve stability of target delineation of clinical target volume in patients with post-operative gliomas.Methods:The post-operative and pre-operative MRI+CT were registrated in nine patients with post-operative gliomas.Clinical target volume in the two registration images and localized CT images were delineated at 5 different times.The image registration accuracy and stability of target delineation were also quantitatively assessed.Results:The registration accuracy in 3D space was always less than 1.5 mm.The concordance index in CT+MRI(pre-matched),CT+MRI(post-matched)and CT(conv)were(68?9)%,(61?7)% and(41?12)% respectively.The same volumes delineated with three sets of images were(82?7)% for CT+MRI(pre-matched),(78?5)% for CT+MRI(post-matched)and(65?8)% CT(conv),respectively.Conclusions:The volume delineated according to pre-operative MRI registered with CT image have the largest volume and the best stability(P
4.Differentially expressed gene in rat hippocampus irradiated by 6MV X-rays
Danming LI ; Xinhu WU ; Xixu ZHU
Journal of Medical Postgraduates 2003;0(05):-
Objective: To observe differentially expressed genes in rat hippocampus irradiated by 6 MV X-rays during radiotherapy.Methods:After whole brain irradiation of 50 Gy in 25 fractions with 2 Gy per fraction,the capability of learning and memory was investigated in a shuttle box model,then rats were killed and the hippocampus were taken,mRNA from sham irradiation group and irradiation group were reversely transcribed to cDNA with incorporation of fluorescence dUTP(Cy5 and Cy3 dUTP) to prepare for hybridization probes.The mixed probes were hybridized to the cDNA microarray.Axon Genechix 4000 BandGenePix Pro3.0 software was used to scan and analyze the fluorescent signals. Results:①The active avoidance response of irradiated rats were lowered significantly.②Compared with the sham group,significant changes took place in 43 genes,among which 28 genes were upregulated and 15 down regulated,other genes did not change significantly.③Among the 43 malexpressed genes,16 were reported previously,others were newly found genes. Conclusion: The influence of ionizing radiation on learning and memory was a complex course,including many transduction factors and might be related to mitochondrial dysfunction.
5.Set-up errors in radiation therapy for pelvic tumor patients of different somatotypes
Danming LI ; Xixu ZHU ; Xinhu WU
Journal of Medical Postgraduates 2003;0(12):-
Objective: The purpose of this study was to quantitatively assess the systematic and random errors in radiation therapy for pelvic tumor patients of different somatotypes and seek an individualized mathematic basis for defining the planning target volume(PTV) and planning organ at risk volume(PRV) in 3 dimensional space.Methods: Thirty patients with pelvic tumor were immobilized by thermoplastic body mask in a spine position and divided into four somatotypes according to their body mass indexes(BMI).CT simulations were performed and digitally reconstructed radiographs(DRR) were generated as the reference image.To define the appropriate PTV-and PRV-margins for intensity modulation radiated therapy(IMRT),inter-fractional set-up errors and intra-fractional organ motions were quantitatively evaluated in the right-left(R-L),anterior-posterior(A-P) and cranial-caudal(C-C) directions.And the frequency of shift in the three directions were observed.Results: For the pelvic tumor patients with different BMIs,the inter-fractional set-up errors of the emaciated,moderate,overweight and obese somatotypes were 1.8,1.8,2.2 and 2.7 mm in the R-L direction,2.2,1.8,3.6 and 2.8 mm in the A-P direction,and 2.4,2.1,2.7 and 2.6 mm in the C-C direction.The intra-fractional organ motions of the four somatotypes were 1.9,1.9,2.3 and 2.5 mm in the R-L,2.1,2.2,2.9 and 3.0 mm in the A-P,and 1.8,1.9,2.2 and 2.5 mm in the C-C direction.Conclusion: In the pelvic irradiation,the definition of PTV and PRV should be individualized.
6.Analysis of MRI-CT image registration accuracy by Tris-Axes Landmark
Danming LI ; Xixu ZHU ; Xinhu WU ; Shuping GAO
Journal of Medical Postgraduates 2003;0(12):-
Objective: To study the accuracy of MRI-CT image registration in order to find a more effective method of image fusion and a standard for the evaluation of post-operative intra-cranial tumor radiotherapy.Methods: Twenty-four patients with intra-cranial tumor underwent MR T1-weighed sequence and post-operative location CT scan under the same location condition.The trans-axial MR T1-weighed sequence and CT image were registered and the correlation between registration scores and errors was analyzed by the method of Tris-Axes Landmark.The linear registration errors were observed in the three-dimensional space of every patient.Results: An improved linear correlation was found between registration scores and errors(r=-0.985,y=-0.551 3x+5.351 4).The registration met the clinical standard when the scores exceeded 6.61.Conclusion: Tris-Axes Landmark is a preferable registration method to be used in clinical radiotherapy for rapid and precise evaluation of MRI-CT image registration accuracy.
7.The characteristic of left ventricular twist changed from infancy to the elder assessed by speckle tracking echocardiography
Yi ZHANG ; Qichang ZHOU ; Lin ZOU ; Ling LI ; Yi TAN ; Danming CAO ; Leiqi TIAN
Chinese Journal of Ultrasonography 2008;17(5):369-373
Objective To assess the characteristic of left ventricular(LV) twist changed from infancy to the elder,in order to determine the normal value of LV twist in different age group.Methods After acquired basal and apical LV short-axis images in 293 healthy volunteers (aged 15 days to 72 years) by 2-dimensional echocardiography, speckle tracking echocardiography was used to analysis LV twist motion offline.The peak apical rotation (PAr), peak basal rotation (PBr), peak LV twist (Ptw), peak LV twist normalized by LV length ( PtwN), peak untwisting velocity ( PutwV), isovolumic untwisting% ( Iutw% ) in different group were compared.Results Reliable LV twist measurements were obtained in 274 volunteers.Different LV twist values were noted according to age.Ptw increased gradually with advancing age, when normalized by LV length, PtwN showed higher values before 3 years old and 25 to 45 years old.PutwV increased with aging from infancy to 25 years old, and leveled off from 25 to 45 years old, then decreased with advancing age.Iutw% was lowest before 3 years old,and increased gradually from 25 to 45 years old,then decreased with aging.Conclusions speckle tracking echocardiography can be used to noninvasively and exactly assess LV twist with high feasibility.The effect of aging on LV twist may reflect the process of maturational and adaptive modulation of LV torsional biomechanics from infancy to the elder.
8.Quantitative assessment of myocardial segmental systolic function in patients with coronary disease by velocity vector imaging
Zurong YANG ; Qichang ZHOU ; Leiqi TIAN ; Shi ZENG ; Yi TAN ; Danming CAO ; Ling LI ; Darong PU
Chinese Journal of Ultrasonography 2008;17(9):749-752
Objective To investigate the clinical significance of velocity vector imaging(VVI)in evaluating the left ventricular(LV)segmental longitudinal systolic function in patients with coronary artery disease(CAD).Methods In 25 patients with myocardial ischemia,28 patients with myocardial infarction,26 patients with coronary lumen stenosis<50%,according to coronary arteriography and electrocardiogram,the myocardial segments of LV were divided into 4 groups:ischemic segments group,infarcted segments group,non-ischemic segments group and normal segments group.Twenty-eight healthy subjects were selected as control group.Dynamic imaging of all subjects were collected,the systolic peak strain(Smax)and strain rate(SRmax),the time to peak strain(PTs)and the time to peak strain rate(PTsr)were measured respectively.Results Smax and SRmax of the ischemic segments and infracted segments were significantly lower than those of the control group respectively,PTs and PTsr of the ischemic segments and infracted segments were significantly longer than those of the control group respectively.Smax and SRmax of infarcted segments were significantly lower than those of the ischemic segments,there were no differences of PTs and PTsr between ischemic segments and infracted segments.Smax and SRmax cutoff of -14.08%,-0.83 s-1 for detecting ischemic segments and cutoff of -6.65%,-0.38 s-1 for detecting infracted segments,respectively,gave an optimal sensitivity and specificity.Conclusions VVI is a kind of novel noninvasive-tool to quantitatively assess LV regional systolic function in CAD patients.It is competent to differentiate between the ischemic segments and infarcted segments.
9.Evaluation of combination of multiple MRI sequences in the differential diagnosis of esophagus cancer
Ting YANG ; Qingbo ZHANG ; Danming LI ; Li WANG
Chinese Journal of Radiology 2019;53(10):892-894
Objective To evaluate the role of combination of multiple MRI sequences in the differential diagnosis of esophagus cancer and to assess the accordance among radiologists with different experience. Methods Thirty?fifty patients underwent conventional MRI including T2 weighted (T2) sequences, gadolinium fat?suppressed T1 weighted sequences (post?contrast T1), and DWI sequences. Three radiologists with different experience determined the possibility of local recurrence (LR) on T2, T2+post?contrast T1, T2+DWI, and T2+post?contrast T1+DWI. ROC and Kappa were used. Results In total, 13 patients had LR. On T2WI, the ROC curve (AUC) achieved by the senior,intermediate and junior groups were 0.701, 0.407, and 0.584, respectively. Compared with simple T2WI sequences, DWI and T1 Gd significantly improved the AUC value for the intermediate radiologist. The great difference was observed between radiologists of different experience (Kappa coefficient was from 0.227 to 0.884). Combination of multiple sequences significantly reduced the diagnostic differences between radiologists with different experience for the senior radiologists particularly. Conclusions The addition of DWI and T1 post?contrast MRI increased diagnostic ability for LR of esophagus cancer and reduced the diagnostic differences between radiologists with different experience compared to T2WI.
10.Real-time ultrasound guided placement of permanent internal jugular vein catheters in maintenance hemodialysis patients.
Fang YUAN ; Yinghong LIU ; Zheng LI ; Jianling ZHU ; Danming CAO ; Yining LI
Journal of Central South University(Medical Sciences) 2014;39(1):61-66
OBJECTIVE:
To investigate the value of real-time ultrasound guided placement of permanent internal jugular vein (IJV) catheterization in maintenance hemodialysis patients, and analyze its technical success and complication rate.
METHODS:
We prospectively analyzed 63 patients (39 males, 24 females) who underwent permanent IJV cannulation with real-time ultrasound guidance from January to October in 2012. Under the real-time guidance of Logiq 5 color Doppler, we placed the tunneled cuffed catheters into the jugular vein by Seldinger technique. The number of needle punctures, technical success, the operation time, and complications were recorded. The patients were divided into a normal-risk group and a high-risk group: those who suffered multiple catheter insertions, previous difficulties during catheterization, poor compliance, obesity, impaired consciousness, skeletal deformity, disorder of haemostasis were regarded as high-risk patients.
RESULTS:
Cannulation of IJV was done in all patients. Of the 63 catheters, 20 (31.7%) were placed in the high-risk patients; 60 (95.2%) were successfully placed at the first attempt, with the average number of punctures of (1.23±0.21) (range 1-3); Only 3 immediate complications (4.7%) developed; 3 (4.7%) catheter infections occurred in the course of using. Cannulation of IJV took longer time in the high-risk group than that in the normal-risk group [(30.6±0.11) min vs (19.1±0.09) min, P<0.05]. The number of needle punctures, percent of successful cannulation, and the frequency of immediate complications were similar in the high- and normal-risk groups. It was more likely to form catheter thrombosis during long-term use in the high-risk group (4/20, 20%) which might cause poor blood flow.
CONCLUSION
Permanent IJV cannulation under real-time ultrasound guidance is very safe with high success rates. Nephrologists can use this technique with ease and with minimal complications in both normal- and high-risk patients.
Catheterization, Central Venous
;
methods
;
Female
;
Humans
;
Jugular Veins
;
diagnostic imaging
;
Male
;
Prospective Studies
;
Renal Dialysis
;
Ultrasonography