1.Clinical Observation of Jianpi Shoushen Decoction for Cases of Impaired Glucose Tolerance with Qi Deficiency and Phlegm-dampness Constitution
Xiaoyan ZHOU ; Daijun YAO ; Yaqian LI ; Xue LI
China Pharmacy 1991;0(03):-
OBJECTIVE: To observe the clinical efficacy of Jianpi shoushen decoction in the treatment of cases of impaired glucose tolerance with Qi deficiency and phlegm-dampness constitution. METHODS:62 Patients with impaired glucose tolerance with Qi deficiency and phlegm-dampness constitution were randomized into 2 groups, i.e. trial group were treated with Jianpi shoushen decoction q.d for 3months (p.o.,n=31); control group were treated with 50 mg Acarbose tablet t.i.d for 3 months (p.o.,n=31). Patients in two groups were all received healthy education such as diet guide and sport instruction. The effective rate, glycemic index and weight index of two groups were observed. RESULTS: The rate of hypoglycemic efficacy and weight lose efficacy in trial group were better than in control group(P
2.Correlation analysis between thromboelastography and liver injury related indexes in patients with heat stroke
LI Xionghui ; LI Daijun ; ZHOU Wenwu ; LIU Jun ; HE Qi
China Tropical Medicine 2023;23(9):983-
Abstract: Objective To analyze the correlation between the thromboelastography (TEG) indexes and the indexes related to liver injury in patients with heat stroke, and explore the diagnostic value of TEG indexes for liver injury in patients with heat stroke. Methods A total of 95 patients with exertional heat stroke (EHS) admitted to 924 Hospital of the Joint Service Support Force of the People's Liberation Army of China from August 2020 to July 22 were selected, and divided into a non-liver injury group (55 cases) and a liver injury group (40 cases) according to whether there was liver injury. TEG instrument was used for the detection of thromboelastography to record the TEG parameters, including reaction time (R), agglutination time (K), α angle, maximum amplitude (MA value), and coagulation complex index (CI). The levels of glutamic transaminase (AST), alanine aminotransferase (ALT), total bilirubin (TBil), albumin (ALB) were detected by automatic biochemical analyzer. Pearson's method was applied to analyze the correlation between thromboelastography indexes R, K, α angle, CI and liver function indexes AST, ALT, TBil, ALB in patients with heat stroke after liver injury. Receiver operating characteristic curve (ROC) was applied to analyze the predictive value of thromboelastography indexes R, K, α angle, CI and combined detection for liver injury in patients with heat stroke. Results Compared with the non-liver injury group, the AST, ALT and TBil levels in patients with heat stroke in the liver injury group were higher (t=26.174, 16.923, 18.414, P<0.05), while the ALB level was lower (t=24.596, P<0.05); compared with the non-liver injury group, the R and K of patients with heat stroke in the liver injury group were higher (t=58.014, 52.862, P<0.05), and the α angle and CI were lower (t=46.853, 60.717, P<0.05); R was positively correlated with AST and ALT (r=0.532, 0.610, P<0.001), and negatively correlated with ALB (r=-0.551, P<0.001) in patients with heat stroke complicated with liver injury; K was positively correlated with AST, ALT and TBil (r=0.661, 0.531, 0.504, P<0.001); α angle was negatively correlated with AST and ALT (r=-0.473, -0.448, P<0.01), and positively correlated with ALB (r=0.539, P<0.001); CI was negatively correlated with AST, ALT and TBil (r=-0.458, -0.505, -0.549, P<0.001); the area under the curve (AUC) of thromboelastography indexes R, K, α angle and CI in predicting liver injury in patients with heat stroke was 0.807 (sensitivity of 70.0%, specificity of 81.6%), 0.831 (sensitivity of 77.5%, specificity of 85.5%), 0.747 (sensitivity of 67.5%, specificity of 74.5%), and 0.788 (sensitivity of 77.5%, specificity of 83.6%), respectively. The AUC of combined detection to predict liver injury in patients with heat stroke was 0.967 (sensitivity of 92.5%, specificity of 91.9%). Conclusions The thromboelastography indexes are correlated with the indexes related to liver injury in patients with heat stroke, and the thromboelastography indexes are helpful to diagnose liver injury in patients with heat stroke.
3.Hygroscopicity of Dry Extract Powder of Hericium Erinaceus and Eathworm Biotransformation
Yuanyuan LIU ; Daijun ZHOU ; Shujin HE ; Guangyu CHEN ; Qiang LI ; Qun HE
China Pharmacist 2017;20(3):413-416
Objective:To confirm the relative humidity conditions of preparation of Hericium Erinaceus and Lumbricus ( HD) bio-transformation and the longest operation time under the conditions through the study on hygroscopicity of dry extract powder. Methods:The solution was prepared respectively in the environment with various humidity, and the moisture absorption rate and critical relative humidity ( CRH) of dry extract powder of HD biotransformation were measured, and then the mathematical model was built and the curves of moisture percentage vs relative humidity was drawn. The parameters of moisture absorption rate, and the relative humidity and operation time with the moisture percentage up to 5% were calculated. The analytic geometry and linear regression method were used to calculate CRH, so as to determine the air humidity control range and the conditions for the production and storage process. Results:The moisture absorption of HD dry extract powder could reach 5% when exposed to the air respectively with the relative humidity of 66. 0%, 80. 8%, 88. 2% and 99. 0% for 7. 088, 3. 953, 2. 892 and 0. 661 h. When the moisture percentage reached 5%, the rela-tive humidity and the shortest time was 50. 84% and 9. 937 h, respectively. The CRH of the dry extract powder of HD biotransforma-tion was 68. 12%. Conclusion:When the dry extract powder of HD biotransformation is under preparation, the relative humidity of en-vironment should be controlled below 50. 84% with the operation time shorter than 9. 937 h, or the relative humidity is controlled below 68. 12% with the operation time shorter than 6. 810 h. Under the above conditions, the moisture absorption rate of HD dry extract pow-der can be controlled below 5%, which does not affect the preparation.
4.Establishment of an enzyme-linked immunosorbent assay for the detection of alcohol dehydrogenase autoantibody and the evaluation of its usage in the diagnosis of autoimmune hepatitis
Jianxuan YANG ; Huiping YAN ; Yufen TAN ; Yan LIU ; Dongmei MA ; Hunqiang LI ; Daijun XIANG ; Dantong ZHAO ; Dongyan ZHOU ; Xiangsha KONG
Chinese Journal of Laboratory Medicine 2009;32(6):669-672
Objective To establish the enzyme-linked immunosorbent assay (ELISA) for the detection of serum alcohol dehydrogenase (ADH) antibody and evaluate its role in its diagnosis of autoimmune hepatitis( AIH ). Methods The reactivity between yeast ADH and human anti-ADH serum antibody was tested by Western blot analysis. ELISA was established using yeast ADH. The method was applied in serums of 67 AIH patients,94 primary biliary cirrhosis(PBC) patients, 199 chronic hepatitis B (CHB) patients, 132 chronic hepatitis(CHC) patients, 24 alcohol hepatitis disease(ALD) patients, 99 connective tissue disease(CTD) patients and 31 healthy individuals. The positive rate of ADH antibody in the patients and healthy individuals was measured. The χ2 test was used to compare the positive rates. Results The ELISA method for detecting human anti-ADH serum antibody was established successfully and the optimum reaction conditions were defined. Western blot showed that yeast ADH has cross reactivity with human anti-ADH antibody. The positive rate of anti-ADH antibody in the AIH group [59. 7% ,40/67 ] was higher than that in the normal control group(0,χ2 = 31. 271 ,P <0. 05), PBC group (6. 4% ,χ2 =54. 492,P <0. 05), CHB group( 14. 1% ,χ2 =54. 848,P <0. 05) ,CHC group(21.2% ,χ2 = 29.269,P<0.05), ALl) group ( 25. 0% ,χ2 =8.512,P <0.05)and CTD group ( 43. 4% ,χ2 =4.229, P <0. 05). Conclusions Compared with the PBC, CHB, CHC, ALD and CTD group, the anti-ADH antibody positive rate in the serums of AIH was significantly increased. The antibody may be helpful to the diagnosis of autoimmune hepatitis.