1.Design of sample collection system for clinical inspection
Kai SU ; Yuzhen CHENG ; Chuanjun TAO ; Erling ZHANG
Chinese Medical Equipment Journal 2004;0(08):-
This paper expounds the design of sample collection system for clinical inspection,which works as the interface of CLIS and CIS.The solution to such problems as bar-code technology,grouping application and quality insurance are discussed,and a new plan for mobile collection is suggested.
2.Simultaneous Determination of the Content of Berberine Hydrochloride,Baicalin and Osthole in Jinchan Zhiyang Capsules by HPLC
Chuanjun HUANG ; Yong MEI ; Li YANG ; Lei LUO ; Bocheng ZENG ; Tao LONG ; Kaichao YUAN ; Zhiwen QIAO ; Xiaoxue CHEN
China Pharmacy 2018;29(12):1621-1624
OBJECTIVE:To establish the method for simultaneous determination of the content of berberine hydrochloride, baicalin and osthole in Jinchan zhiyang capsules. METHODS:HPLC method was adopted. The determination was performed in Hypersil BDS C18 column with mobile phase consisted of methanol-acetonitrile-0.1%phosphoric acid-three triethylamine(50∶30∶19∶1, V/V/V/V) at the flow rate of 1.0 mL/min. The detection wavelengths were set at 265 nm (berberine hydrochloride),280 nm (baicalin)and 322 nm(osthole). The column temperature was set at 30 ℃,and sample size was 10 μL. RESULTS:The linear range of berberine hydrochloride,baicalin and osthole were 80-800 ng(r=0.999 8),60-600 ng(r=0.999 9),60-600 ng(r=0.999 6),respectively. RSDs of precision,stability and reproducibility tests were all lower than 2.0%. The limits of quantitation were 80,60,60 ng,respectively,and the limits of detection were 24,20,20 ng,respectively. The recovery rates were 97.4%-98.3%(RSD=0.33%,n=6),98.4%-99.6%(RSD=0.42%,n=6)and 96.9%-99.0%(RSD=0.92%,n=6),respectively. RSDs of durability tests were all lower than 1.2%. CONCLUSIONS:The method is simple, accurate, precise, stable, reproducible and durable. It can be used for simultaneous determination of berberine hydrochloride,baicalin and osthole in Jinchan zhiyang capsules.
3.Simultaneous Determination of Berberine Hydrochloride and Baicalin in Jianpi Zhixiening Granules by HPLC-switching Walvelength Method
Chuanjun HUANG ; Li YANG ; Yong MEI ; Lei LUO ; Shanshan LYU ; Bocheng ZENG ; Tao LONG ; Feng WANG ; Juan ZUO ; Kaichao YUAN ; Pan TANG ; Feng ZHU ; Bo CHEN ; Zhiwen QIAO
China Pharmacy 2018;29(10):1324-1327
OBJECTIVE:To establish the method for simultaneous determination of berberine hydrochloride and baicalin in Jianpi zhixiening granules. METHODS:HPLC switching walvelength method was adopted. The determination was performed on Hypersil BDS C18 column with mobile phase consisted of methanol-0.45% phosphoric acid solution-triethylamine(50:49:1,V/V/V) at the flow rate of 1.0 mL/min. The detection wavelength was set at 265 nm(berberine hydrochloride)and 280 nm(baicalin). The column temperature was set at 30 ℃,and sample size was 10 μL. RESULTS:The linear range of berberine hydrochloride and baicalin were 60.3-312.8 ng(r=0.9997)and 81.5-368.9 ng(r=0.9999). The limits of quantitation were 0.6668,0.7740 ng,andthe limits of detection were 0.2226,0.2580 ng,respectively. RSDs of intermediate precision,stability and repeatability tests were all lower than 1.0%. The recoveries were 96.48%-99.30%(RSD=1.06%,n=6) and 95.20%-99.39%(RSD=1.66%,n=6), respectively. RSDs of durability test were all lower than 2.0%. CONCLUSIONS:The method is simple, precise, stable, reproducible,accurate and durable. It can be used for simultaneous determination of berberine hydrochloride and baicalin in Jianpi zhixiening granules.