1.MR imaging features with pathologic correlation in adenomyosis
Jinwen HOU ; Hua CHENG ; Chuanfu LI
Chinese Journal of Radiology 2001;0(01):-
Objective To evaluate the usefulness of MRI in the diagnosis of adenomyosis. Methods Sagittal Turbo SE T 1WI, T 2WI, T 1SPIR and T 2SPIR MRI examination were performed on 30 cases with adenomyosis. Results The lesions in 12 cases with diffuse adenomyosis were demonstrated as diffusely thickened junctional zone (JZ) measured 10~35 mm (mean 18 mm) On T 2WI. 6 of them were of homogenous hypointensity. Another six had hyperintensive foci within the hypointensive lesions on T 2WI, and these hyperintensive foci could also be found on T 1WI in 5 lesions. 23 focal lesions (adenomyomas) in 18 cases were oval, irregular or round masses with hypointensity that were the same as the intensity of JZ on T 2WI. They were from 2.0-7.5 cm in diameter (mean 3.9 cm), and all but one showed ill-defined margins. 15 masses hadhyperintensive foci within the hypointensive lesions on T 2WI and 12 of 15 presented hyperintensity on T 1WI. The diffusely thickened JZ and focal masses correspond to the hyperplastic and hypertrophic musculature around the heterotopic endometrial islands. The hyperintensive foci were correlated with the heterotopic endometrial islands. The hyperintensive foci showed only on T 2WI corresponded to the heterotopic endometrial islands without hemorrhage. The hyperintensive foci shown on both T 2WI and T 1WI were the heterotopic endometrial islands with hemorrhage. Conclusion MRI is the modality of choice for the diagnosis of adenomyosis. T 2WI is the most useful sequence. T 2WI combining with T 1WI, T 1SPIR, and T 2SPIR can improve the accuracy in the diagnosis of adenomyosis.
2.Study of the size and configuration of the third ventricle of the normal fetus in the second and third trimester by ultrasonography
Guowei TAO ; Chuanfu LI ; Zhe MA ; Xinfeng ZHAN ; Lin CHENG ; Yao SONG ; Shaoping LIU
Chinese Journal of Ultrasonography 2008;17(5):402-404
Objective To observe the normal configuration and size of the third ventricle in the second and third trimester fetuses in a normal population by ultrasonography. Methods The third ventricular width and configuration were obtained by antenatal ultrasonography in 765 fetuses with gestational age between 27 weeks and term.The relationship Between the width and the gestational age was analyzed.Results The third ventricle width 0~3 mm and showed the increased tendency; the correlation coefficient ( r ) between the width of the third ventricle and the gestationl week was 0.473 ( P<0.01).The third ventricle was seen as a single echogenic line in 8(4.8%) of 165 fetuses, 145(61.5%) of all fetuses had parallel echogenic lines outlining a fluid-filled lumen, the V-shaped configuration of the third ventricle was seen in 12(7.3%) of the fetuses.Conclusions The third ventricle width shows the increased tendency in the second and third trimester.The parallel echogenic line becomes the prominent ultrasonography appearance in the second and third trimester fetuses.It's usefull to observe the normal ultrasonic apperance of the third ventricle in diagnosing the fetal central nervous abnormities.
3.Application of Micro-Electro-Mechanical-System Probe and Low-power & Low-noise Single Chip Integration System in Neural Loop Researching
Jianhui SUN ; Xinxia CAI ; Juntao LIU ; Chunxing WANG ; Dengwang LI ; Zeyuan CHEN ; Chuanfu CHENG ; Jinhui WANG ; Dongmei HU
Chinese Journal of Analytical Chemistry 2017;45(4):611-619
A 8-channel neural signal′s simultaneous transducer detection micro system was developed to research the neural loop located at the brain hippocampus zone. The components of the system contained the neural probe manufactured with the Micro-electro-mechanical-systems (MEMS) technique based on silicon-on-insulator (SOI) substrate, biological low noise chopper-stabilization amplifier, low noise and intermediate speed SAR-ADC converter, reduced and low power ASK/FSK modulation radio transmitter. The micro system was applicable with the characters of small volume, interferences free, neural electrophysiology and neurotransmitter simultaneous detection, high sensitivity, high linearity, etc. The electrode resistance was optimized to 35.0 kΩ after depositing nanometer platinum black on the 4 electrophysiological sites on the Pt electrode. With the modification enzyme technique, nanomaterial enzyme membrane (Pt-mPD-GluOx) was directly fixed on the glutamate detection locus for selectively detecting special neural neurotransmitter matter. In addition, the electrochemistry measurement results indicated that the linear range of glutamate was 6-35 μmol/L with correlation coefficient of 0.97, the sensitivity was 0.0069 pA/(μmol/L). The current response error was less than 3.0 pA, which showed that the neural needle satisfied differential selection. Also, the logic/analog mixed signal 180-nm Application specific integrated circuit (ASIC ) technique (SmicRF180 nm 1Poly6M) was used to manufacture the transducer back-end disposing IC chip, and the test results provided some key parameters such as chopper-stabilization amplifier (equivalent in putting noise voltage ≤0.7 μV rms@1 kHz, gain of 71-82 dB, CMRR/PSRR>100 dB), SAR-ADC (ENOB is 12 bits, power consumption is 1.2 mW when maxmium conversion speed is 1 Msps, signal-noise-ratio is 60.9 dB, etc), and ASK/FSK modulation radio transmitter (the PA′s outputting power of 4-5 dBm, the radiation range of 10 meters). The micro neural transducer integrated system was convenient and wireless wearable for the research of brain hippocampus region.