1.The Software Design of Real Time Processing System for Body Surface Detection of Late Potential on Microcomputer
Chinese Medical Equipment Journal 1989;0(04):-
This papar describes the software designing method and principle of three leads real time pro- cessing system for body surface detection of late potential is used on IBM-PC/XT microcomputer.It aslo in- troduces system's basic structure,working principle,averaging processing,setting of template wave,setting of interrupt controller and timer,and eliminating of abnormal heart beat et al.
2.Explore the feasibility of preventive maintenance model of hemodialysis machine based on quality control detection
China Medical Equipment 2014;(11):60-61,62
Objective:To investigate the feasibility of hemodialysis machine preventive maintenance model of based on quality control detection.Methods: Selected sample of 32 hemodialysis machines of two major imported brands, 16 of them using the traditional preventive maintenance mode for maintenance, and the other 16 sets of quality control detection based preventive maintenance hemodialysis machine maintenance mode. That: by use of HDM99XP detector instrument for testing the five hemodialysis machine main indicators, maintenance cycle is 16 weeks, and then the equipment failure rate indicators of two modes of preventive maintenance were compared.Results: The hemodialysis machine preventive maintenance model of based on quality control detection rise superior to the traditional maintenance mode in lower failure rate, quantitative, objective, and less affected by human factors.Conclusion: The hemodialysis machine preventive maintenance model of based on quality control detection was better than the traditional preventive maintenance mode,also a promising preventive maintenance mode.
3.The giant mucous cyst of frontoethmomaxillary sinus: one case report.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2014;28(10):750-750
One case of rare giant mucous cyst of nasal sinus that implicated frontal, ethmoid and maxillary sinus was in our hospital. The patient manifested mainly slowly developing swelling and pain of cheek, exophthalmos and visual impairment. The image studies indicated cyst of nasal sinus, including frontal, ethmoid, and maxillary sinuses. The clinical diagnosis was cyst of frontoethmomaxillary sinus.
Aged
;
Female
;
Humans
;
Maxillary Sinus
;
Mucocele
4.Percutaneous compressive screw fixation for float injury to pubic symphysis
Xiaoshan GUO ; Lei YANG ; Yonglong CHI
Chinese Journal of Orthopaedic Trauma 2009;11(7):625-628
Objective To discuss the functional results of percutaneons compressive screw fixation for float injury to the pubic symphysis. Methods From March 2003 to March 2007, 48 cases of float injury to the pubic symphysis were treated with percutaneons compressive screws, including 27 males and 21 females with an average age of 29.4 years. Of them, 39 eases were complicated with injury to the pelvic posterior ring. Emergency surgery was done for 13 cases, 27 cases were operated on within 3 to 7 days after injury and 8 within 7 to 14 days. Guided pins and screws were used during dosed reduction and percutaneous pelvic fixation was done under the guidance of intraoperative fluoroscopic imaging. Float injury to the pubic symphysis was amended by percutaneous fixation after dosed manipulation. Results The average operation time for the48 patients was 55 (31 to 100) min. The intraoperative bleeding averaged 20 to 30 mL. Satisfactory reduetian and fixation was achieved in 41 cases, but 7 cases had poor reduction. All the fractures healed 3 to 6 months postoperatively without infection, nonunion or injury to vessels, nerves or organs. All the patients could turn the body freely in bed the day after operation. Those without injury to the pelvic posterior ring could walk with crutches 3 days after operation. By the Orlando evaluation system for pelvic fractures, 37 eases were rated as excellent, 7 as good, 3 as fair and I as poor. Conclusions The percutaneous compressive screw fixation may decompress the pelvic hematoma, allowing early definitive fixation without the risk of additional hemorrhage. Complications associated with open posterior pelvic surgical procedures may be avoided by using percutaneons techniques.
5.Peripheral neuropathy in multiple sclerosis: a clinical and electromyographic study
Lihua GUO ; Wei WU ; Zhaofu CHI
Journal of Clinical Neurology 1992;0(01):-
Objective To investigate the clinical and electromyographic features of peripheral nerve involvement in MS. Methods The clinical and electromyographic (EMG) data of 29 MS patients were evaluated retrospectively.Results 18 (62.1%) patients showed clinical and/or electromyographic abnormalities of peripheral nerves. The clinical symptoms included extremity numbness in 16 cases (88.9%), limb inertia in 11 cases (61.1%), radicular pain in 5 cases (27.8%), autonomic nerve disorder and dysphagia in few patients. Signs included decrease of tendon reflex in 11 cases (61.1%), periphery or root form hypoesthesia in 9 cases (50%), muscle weakness in 7 cases (38.9%), myatrophy in 4 cases (22.2%), and reduced pharyngeal reflex in 1 case (5.6%). There was no difference in age of onset, course of disease, neurologic impairment and prognosis between the patients accompanied with peripheral neuropathy and the patients without peripheral neuropathy. The electromyographic abnormalities included spontaneous potential in 4 cases (13.8%), increased motor unit potential in 8 cases (27.6%), slow MCV in 15 cases (51.7%), slow SCV in 13 cases (44.8%), low amplitude in 9 cases (31.1%), and prolonged distal latency in 5 cases (17.2%). The neuropathies improved by treatment with corticosteroid in the all patients except one.Conclusions Some MS patients may accompany with peripheral nerve abnormalities, which may improve with the recovery of MS. EMG is useful to evaluale the site and degree of peripheral nerve damage.
6.Data acquisition system based on LabVIEW platform
Peixin CHEN ; Xiaomin WANG ; Chi GUO
Chinese Medical Equipment Journal 1989;0(02):-
This paper introduces the hardware of data acquisition system based on LabVIEW platform, i.e. the system for data acquisition and control. The system is composed of the units for signal selection, programmable magnification, filtration, restriction, and A/D and D/A conversion circuits. With the system, the following can be available including eight-channel low-frequency signals, eight options on programmable magnification, 1000Hz low-pass filter, 50Hz power-frequency trap, and A/D and D/A conversion.
7.Application of wavelet transforms to ECG characteristic points recognition
Peixin CHEN ; Xiaomin WANG ; Chi GUO
Chinese Medical Equipment Journal 1993;0(05):-
Wavelet transforms are used in detecting ECG characteristic points recognition.The relationships between ECG characteristic points and the modulus maximum pairs of their wavelet transfoms are expounded.The application perspective of wavelet transforms to ECG characteristic points recognition is predicted through the analysis of the results.
8.Opinions concerning work of third class medical metrology stations in military hospital
Xiaomin WANG ; Yiyong LI ; Chi GUO
Chinese Medical Equipment Journal 2004;0(08):-
This paper puts forward existing problems and conflicts in the work of third class medical metrology stations in army,raises suggestions from 5 aspects including enhancing metrology awareness,fulfilling rules,setting strict standards,etc.
9.Construction and Management of Medical Engineering Department in Military Hospital
Chi GUO ; Xiaomin WANG ; Yiyong LI
Chinese Medical Equipment Journal 1989;0(03):-
The military hospital's department of medical engineering is limited by authorized size and system.The existing problems in the construction of department of medical equipment are analyzed and some suggestions are given.The construction of department of medical equipment should be made up of three parts: equipment repairing department,medical metrology department and archives department.The construction is also discussed in such aspects as the rules,methods,goals,human resource management,engineer's training program,and reparing mode.
10.Working Principle and Application of Adaptive Support Ventionlation
Yongwei MI ; Yiyong LI ; Chi GUO
Chinese Medical Equipment Journal 1989;0(04):-
By introducing the basic concept and principle, the advantages and characteristics of ASV technology are highlighted. Based on clinical application, suggestions on how to correctly set ASV parameters are given.