2.Intense pulsed light and red light emitting diode for the treatment of steroid-dependent dermatitis
Jing WANG ; Bin LIU ; Qi LUAN ; Yanting WANG ; Chengxin LI
Chinese Journal of Dermatology 2012;45(3):205-207
Objective To retrospectively review the efficacy and side effects of intense pulsed light (IPL) and red light emitting diode (LED) in the treatment of steroid-dependent dermatitis.Methods Seventy patients with steroid-dependent dermatitis mainly manifesting as facial telangiectasis were treated with IPL for an average of 3.49 sessions with a 4-week interval.The energy density of IPL varied from 20 to 23 J/cm2,pulse width from 2.6 to 5.0 ms,and delay from 15 to 20 ms.Meantime,197 patients with steroid-dependent dermatitis,who mainly presented with facial skin sensitivity,were treated with red LED (633 ± 3 nm wave length) twice a week for an average of 4.23 sessions.The energy density of red LED was 128 J/cm2,and the irradiation lasted 20 minutes at each treatment.The efficacy and adverse reactions were assessed and recorded for each treatment.Results The total response rate was 88.57% for IPL,and 83.76% for red LED.There was a significant difference in the clinical efficacy between triple-pulse and double-pulse IPL (x2 =8.14,P < 0.05).No severe adverse reaction was observed in any of the patients.Conclusion IPL and red LED are both effective in treating steroid-dependent dermatitis.
3.Prognostic values of blood parameters on mortality in octogenarian population: a nine-year-follow-up study
Hua WANG ; Xuezhai ZENG ; Jiefu YANG ; Deping LIU ; Chengxin BAO
Chinese Journal of Geriatrics 2012;31(9):762-766
Objective To evaluate the prognostic values of leukocyte count,hemoglobin,biochemical parameters,erythrocyte sedimentation rate and immunoglobulin on mortality in patients aged 80 years and over.Methods Totally 342 patients(aged 85.6±4.0 years)were followed up for (82.0±36.9) months,and the cause and time of death were recorded.Results During the period of follow up,198 patients suffered from death.Compared with the survival group (132 cases),the death group had older age [ (86.5±4.4)years vs.(84.5±3.2)years,t=-4.86,P<0.01 ],higher white blood cell [ (6.2± 1.7) > 109/L vs.(5.5±1.3) × 109/L,t=-3.93,P<0.01 ],lower hemoglobin [(134.4±14.4)g/L vs.(140.0± 12.6)g/L,t= 3.65,P<0.01 ],slightly faster erythrocyte sedimentation rate [ 11 mm/h(15 mm/h) vs.9 mm/h (10 mm/h),U=- 3.31,P<0.01 ],lower immunoglobulin M [ (0.9±0.5)mg/L vs.(1.1±0.8)mg/L,t =2.55,P<0.05 ],slightly higher urea nitrogen [ (7.5±2.6) mmol/L vs.(6.8±1.6) mmol/L,t=2.81,P<0.01]and creatinine [(113.0±32.5) μmol/L vs.(100.5±15.8) μmol/L,t=-4.65,P<0.01 ].Cox multivariate analysis revealed that older age (RR=1.083,95%CI:1.040 1.127,P<0.01),white blood cell count (RR=1.134,95%CI:1.021-1.260,P<0.05),creatinine (RR=1.011,95%CI=1.0021.020,P<0.05),hemoglobin(RR=0.835,95%CI:0.714-0.975,P<0.05)andimmunoglobulin M(RR=0.710,95%CI:0.521-0.966,P<0.03),aorticaneurysm(RR=2.144,95%CI:1.163-3.951,P < 0.05 ) were the independent risk factors for death.Conclusions Aging,increased WBC count,decreased hemoglobin and immunoglobulin M,elevated creatinine and aortic aneurysm are the independent risk factors for death,which are powerful parameters for the prognostic evaluation in the elderly aged 80 years and over.
4.Effects of irradiation with 1064-nm Q-switched Nd:YAG laser on melanogenesis in cultured PIG cells in vitro
Ling WANG ; Chengxin LI ; Dongning ZHU ; Zhe JIAN
Chinese Journal of Dermatology 2010;43(10):713-716
Objective To study to the effect of 1064-nm Q-switched Nd:YAG laser irradiation on the melanogenesis in a human epidermal melanocyte line PIG. Methods Cultured PIG cells were irradiated with 1064-nm Q-switched Nd:YAG laser (Medlite C6) at different energy densities for 10 times. After additional culture for various durations, cell viability was detected by MT assay, tyrosinase activity by dopa oxidation assay, mRNA and protein expressions of tyrosinase, tyrosinase related protein (TRP)-1 and TRP-2 by real-time quantitative fluorescent RT-PCR and Westen blotting respectively, Results The irradiation with Q-switched Nd:YAG laser at energy densities from 1 to 3 J/cm2 had no obvious effect on the viability of PIG cells. After irradiation with Nd:YAG laser at 1 J/cm2, PIG cells showed a significant increase in the tyrosinase activity,mRNA expressions of tyrosinase and TRP-1 compared with unirradiated cells (0.563 ± 0.014 vs 0.501 ±0.019, 1.40±0.11 vs 1.0, 1.28 ± 0.03 vs 1.0, all P< 0.05), but both the mRNA (0.91 ± 0.17 vs 1.0, P>0.05) and protein expressions of TRP-2 experienced no significant changes before and after the irradiation.However, a significant decrease was noted in PIG cells irradiated with Nd:YAG laser at 3 J/cm2 in tyrosinase activity, mRNA and protein expressions of tyrosinase (0.70 ± 0.02 vs 1.0, 0.64 ± 0.05 vs 1.0, both P < 0.05),TRP-1 (0.73±0.04 vs l.0, 0.86±0.17 vs l.0, both P<0.05) andTRP-2 (0.68±0.04 vs l.0,0.69±0.11vs 1.0, both P <0.05) in comparison with unirradiated PIG cells. Conclusions The 1064-nm Q-switched Nd:YAG laser irradiation may affect the melanogenesis in PIG cells. With no influence on cell viability, the 1064-nm Q-switched Nd:YAG laser at 1 J/cm2 could enhance melanogenesis, while that at 3 J/cm2 could suppress melanogenesis, in PIG cells.
5.Early diagnosis values of C-reactive protein and procalcitonin for children with bacterial infectious pneumonia
Qingfu LI ; Wen FANG ; Chengxin WANG ; Lifan ZHANG ;
International Journal of Laboratory Medicine 2015;(11):1586-1588
Objective To explore the early diagnosis value of C‐reactive protein (CRP) and procalcitonin (PCT ) for bacterial in‐fectious pneumonia of children .Methods A total of 101 children with bacterial infectious pneumonia ,64 children with non‐bacterial infectious pneumonia and 73 children with non‐infectious disease were selected in bacterial infectious pneumonia group ,non‐bacterial infectious pneumonia group and non‐infectious disease group respectively .Serum PCT and CRP levels were measured before treat‐ment in the three groups .With sputum culture results as gold standard for the diagnosis of bacterial infectious pneumonia ,the sensi‐tivity ,specificity ,positive predictive value ,negative predictive value ,Youden index and diagnostic accuracy of PCT ,CRP ,PCT /CRP series test and parallel test were calculated for bacterial infectious pneumonia diagnosis .Results The levels of PCT and CRP of children in bacterial infectious pneumonia group were significant higher than those of children in non‐bacterial infectious pneumonia group and non‐infectious disease group(P < 0 .05) .The sensitivity ,specificity ,positive predictive value ,negative predictive value , Youden index and diagnostic accuracy of PCT ( ≥ 0 .5 ng/mL as the best intercept point) for bacterial infectious pneumonia diagno‐sis were 0 .743 ,0 .719 ,0 .806 ,0 .639 ,0 .461 and 0 .733 .And the same values for PCT /CRP series test were 0 .604 ,0 .875 ,0 .884 , 0 .583 ,0 .479 and 0 .709 respectively .All the values were higher than those of children in non‐bacterial infectious pneumonia group and non‐infectious disease group except sensitivity .Conclusion The combination of PCT and PCT /CRP series test is ideal method for early diagnosis of bacterial infectious pneumonia with high sensitivity and specificity .
6.Efficiency and safety of Lightsheer 800 nm diode laser in hair removal
Rui MA ; Jun FU ; Yanchun WANG ; Bin LIU ; Chengxin LI
Chinese Journal of Medical Aesthetics and Cosmetology 2011;17(4):247-249
Objective To evaluate the efficiency and safety of hair removal with Lightsheer 800 nm diode laser. Methods Lightsheer, 800 nm diode laser, was used to remove hairs from different areas, including hairlines, lips, whiskers, armpit, chest, back, limbs and bikinis area, in 432 patients. Results At least twice treatments, the maximum 29 times, were needed to achieve satisfactory results. Total effective rate increased with the treatment times but depended on the different area:63.4 % of hairlines, 67.7 % of lips, 71.9 % of whiskers, 100 % of armpit, 100 % of chest, 100 %of back, 82.6 % of limbs and 100 % of bikinis area, respectively. The adverse effect was observed with temporal hypopigmentation in 4 patients and hyperpigmentation in 9 patients, without any scar formation. Conclusions Lightsheer 800 nm diode laser is a safe and efficient method of laser hair removal.
9.Immunologic Characterization of a Genetically Engineered Human Antibody Against Keratin
Ning LU ; Gang WANG ; Yufeng LIU ; Chengxin LI ; Wei LI ; Hailong ZHANG ; Xiaodong ZHAO
Chinese Journal of Dermatology 1995;0(04):-
Objective To immunologically characterize the binding activity of a genetic engineering human antibody against keratin. Methods The specific anti-keratin Fab was screened from a phage antibody library. After Fab monoclonal antibody was induced by isopropylthio-?-D-galactoside (IPTG), the binding activity with antigens and antigenic specificity of the antibody were verified by ELISA,Western blot, and competitive inhibition ELISA. Results The antibody possessed good antigenic specificity as well as excellent binding activities with antigens, and could recognize 46 000 keratin specifically. It was identified as anti-keratin 17 antibody. Conclusions The immunologic characteristics of the genetic engineering antibody are very good. It is necessary to further study the biological activities and clinical application of it.
10.Preparation and Characterization of Hybridoma Strains Secreting Natural IgM Against Keratin
Meng FU ; Wei LI ; Gang WANG ; Yanguo ZHANG ; Chengxin LI ; Pingshen FAN ; Yufeng LIU
Chinese Journal of Dermatology 1995;0(04):-
Objective To prepare natural anti-keratin IgM monoclonal antibody. Methods Spleen cells of BALB/c mice raised in specific pathogen free conditions were directly fused with Sp2/0 myeloma cells. The hybridoma supernatants were tested by ELISA using pre-extracted keratin. The natural IgM obtained was further identified by immunochemistry and immunoblot methods. Results The cell fusion rate was about 60% without pre-immunization. About 14% supernatants reacted with the keratin antigen. Three hybridoma strains secreting natural IgM monoclonal antibody against keratin were obtained. The immunochemistry results showed that the natural anti-keratin IgM was able to bind to epidermis, sebaceous gland, hair follicule, and muscle tissues. Conclusion B lymphocytes in normal BALB/c mice spleen can produce natural antibody against kerain.