1.Research Advances in Tetraspanins in Colorectal Cancer
Chengwei LIU ; Kunyang WANG ; Zhen HU ; Yaoping LI
Cancer Research on Prevention and Treatment 2025;52(5):361-367
The tetraspanins are closely associated with the development and therapeutic prognosis of colorectal tumors. These proteins play a role in cell proliferation, metastasis, and invasion, regulate apoptosis and autophagy of colorectal tumor cells. affect immune escape by releasing exosomes, intervening the epithelial-mesenchymal transition process, and altering the tumor microenvironment, and enhance tumor stemness through specific pathways. This paper reviews the mechanisms and current research regarding the status of tetraspanins in colorectal cancer, aiming to improve early diagnosis and providing valuable insights for treatment strategies.
2.Correlation between CT-based arterial radiomics score and the neo-adjuvant treatment response of pancreatic cancer
Mengmeng ZHU ; Yun BIAN ; Chengwei CHEN ; Jian ZHOU ; Na LI ; Yifei GUO ; Ying LI ; Xiaohan YUAN ; Jieyu YU ; Jianping LU
Chinese Journal of Pancreatology 2024;24(3):190-197
Objective:To identify the relationship between the CT arterial radiomics score and the treatment response to neoadjuvant therapy for pancreatic cancer.Methods:The clinical data of 243 pancreatic cancer patients who received surgical resection after neo-adjuvant therapy in the First Affiliated Hospital of Naval Medical University from March 2017 to March 2023 were retrospectively analyzed. Based on the tumor regression grade (TRG), the patients were divided into good response group (TRG 0-1, n=30) and non-good response group (TRG 2-3, n=213). The clinical, radiological and pathological features were compared between two groups. Fully-automated segmentation tool was used for segmenting the arterial CT scan of pancreatic tumor before and after treatment. Python package was applied to extract the radiomics features of tumors after segmentation and the extracted features were reduced and chosen using the least absolute shrinkage and selection operator (Lasso) logistic regression algorithm. Lasso logistic regression formula was applied to calculate the arterial radiomics score. Univariate and multivariate logistic regression models were used to analyze the association between arterial radiomics score and treatment response to neoadjucant therapy. Receiver operating-characteristics (ROC) curve was drawn and area under curve (AUC), specificity, sensitivity and accuracy for evaluating the treatment response were calculated. The clinical usefulness of arterial radiomics score for diagnosing the response of neoadjuvant treatment for pancreatic cancer were determined by decision curve analysis (DCA) . Results:A total of 330 arterial radiomics CT features were obtained, and 9-selected arterial phase features associated with treatment response were determined after being reduced by the Lasso logistic regression algorithm. Univariate analysis showed that the arterial radiomics score, three-dimensional diameter after neoadjuvant therapy, pancreatic contour, T stage, N stage, Peri-pancreatic nerve invasion, lymph-vascular space invasion (LVSI) and invasion of duodenum were all associated with treatment response (all P value <0.05). Multivariate logistic regression analyses confirmed that arterial radiomics score was obviously associated with the neoadjuvant treatment response ( P<0.001). At the cut-off value of 1.93, AUC of the arterial radiomics score for diagnosing neoadjuvant treatment response was 0.92, and the specificity, sensitivity and accuracy was 86.7%, 84.5% and 84.8%. DCA demonstrated that when the percentage for predicting the treatment response by using the arterial radiomics score was >0.2, the patients could benefit from the application of arterial radiomics score for evaluating neoadjuvant therapy response. Conclusions:The arterial radiomics score was strongly correlated with the neoadjuvant treatment response of pancreatic cancer, and can accurately predict neoadjuant treatment efficacy.
3.Clinical study of the effect of different CBCT scanning parameters on image quality and positioning error of cervical cancer
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Jiang LIU
China Medical Equipment 2024;21(11):18-24
Objective:To assess the effects of the scanning parameters of cone beam computed tomography(CBCT)on image quality,positioning error and additional radiation dose for patients with cervical cancer after tube voltage was reduced,so as to explore scanning conditions that was suitable to patients with cervical cancer.Methods:Seventy-two patients with cervical cancer who received radiotherapy in Deyang People's Hospital from January 2020 to August 2022 were selected.According to different scanning parameters,they were divided into low-dose group A(120 kV,154.4 mAs),low-dose group B(120 kV,228.8 mAs)and conventional group[adopted business-supplied scan sequences(120 kV,675.8 mAs)].The CBCT scan image was obtained by decreasing the tube voltage and tube current,and reducing scanning angle.The registration results of positioning error of low-dose group A,B and conventional group on three directions included left and right(x-axis),head and foot(y-axis)and abdominal and back(z-axis)were respectively obtained,and the results were analyzed by variance analysis.The Catphan503 phantom of X-ray volumetric imaging(XVI)was used to measure the image quality of the corresponding 3 groups,and the further comparison was conducted.Results:There were no significant differences between the three groups in the scanning parameters on x,y and z axis directions for positioning error of patients with cervical cancer(P>0.05).The scanning times of low-dose group A and B were approximately 1 minute,and the scanning time of conventional group was approximately 2 minutes.The noises of low-dose group A and B,and conventional group were respectively 36.51%,26.09%and 18.37%,and the radiation dose that was generated by CBCT image scanning in group A was correspondingly reduced.Conclusion:The reductions of scanning speed and collimator size of CBCT scanning parameters do not affect the positioning error and image quality,and it can decrease the scanning time and additional radiation dose of patients in undergoing radiotherapy.
4.Computer-aided design of an improved lamina hook and finite element analysis of its use in fixation of lumbar spondylolysis
Hongliang GAO ; Hua LIU ; Tao ZHANG ; Chengwei YANG ; Yizhe WANG ; Zirong HUANG ; Wenhua ZHANG ; Long CHEN ; Bing KANG ; Yuxuan MA ; Songkai LI
Chinese Journal of Trauma 2024;40(7):593-604
Objective:To design an improved lamina hook system and compare its biomechanical properties with traditional lamina hook system in fixation of lumbar spondylolysis.Methods:The thin layer CT data of the lumbosacral vertebrae of 20 healthy young male servicemen who underwent physical examination in the outpatient department of the 940th Hospital of Joint Logistics Support Force of PLA from January 2021 to August 2022 were collected. The age of the subjects was 20-30 years [(25.0±3.0)years]. A 3-dimensional model of the L 5 vertebral body was constructed using the 3-dimensional modeling software. The new improved lamina hook was designed according to the measurements including the thickness of the middle area, the longest longitudinal diameter, the curvature radius of the lower edge, the angle between the upper and lower tail ends, the thickness of the lower edge, and the longest diameter of the lower edge of the bilateral L 5 vertebral plates. One serviceman was selected from the aforementioned group to construct a linear finite element model of segments L 4-S using the 3-dimensional virtual software (normal model, model A), based on which, the L 5 bilateral spondylolysis model (model B), improved lamina hook model (model C) and traditional lamina hook models (model D) were designed. By constraining both sides of the sacrum and applying a longitudinal load of 400 N on the L 4 vertebral body, the upper 1/3 gravity of the body was simulated, and with a bending moment of 10 N·m along the X, Y, and Z directions, motions of forward flexion, backward extension, lateral bending, rotation, etc were simulated. The range of motion of segment L 4/5 and L 5/S 1 of model A was evaluated and compared with the findings of the previous researches to verify its effectiveness. The overall range of motion of models A, B, C, and D, the range of motion of segment L 4/5 and L 5/S 1, the maximum overall displacement, the maximum displacement and stress of the isthmus, the stress distribution and maximum stress of internal fixation of models C and D, and the stress distribution and maximum stress of the vertebral body of models C and D were compared. Results:(1) During forward flexion, backward extension, lateral bending and rotation, the range of motion of model A was 5.01°, 4.03°, 3.91° and 1.42° in segment L 4/5, and was 4.62°, 2.51°, 2.40° and 1.23° in segment L 5/S 1. (2) The overall range of motion, range of motion of segment L 4/5 and L 5/S 1 and maximum overall displacement of models A, C, and D were similar in axial compression, forward flexion, backward extension, left bending, and left rotation, while those of model B were significantly increased. (3) There was no significant difference in the maximum displacement of the isthmus of models A, C, and D under different motion modes, while the maximum displacement of model B in the isthmus was significantly larger than that of models A, C, and D, especially during rotation, increased by 295%, 277%, and 276% respectively. The maximum stress of the isthmus of model C was 0.938 MPa, 1.698 MPa, 0.410 MPa, 2.775 MPa, and 1.554 MPa respectively. The maximum stress in the isthmus of model D was 0.590 MPa, 1.297 MPa, 0.520 MPa, 3.088 MPa, and 2.072 MPa respectively. The maximum stress of the isthmus of models C and D was similar during axial compression and forward flexion, while the stress of the isthmus of model C was smaller than that of model D during backward extension, lateral bending, and rotation, decreased by 21.1%, 10.2%, and 25.0% respectively compared with model D. (4) The maximum stress of internal fixation in models C and D during forward flexion, backward extension, left bending, and left rotation was 135.220 MPa, 130.180 MPa, 200.940 MPa and 306.340 MPa respectively, and was 131.840 MPa, 112.280 MPa, 349.980 MPa and 370.140 MPa respectively. The maximum stress of internal fixation in the two models of internal fixation during forward flexion and backward extension was similar, while it was decreased by 42.6% and 17.2% in model C during left bending and left rotation, compared with model D. (5) The maximum stress of the vertebral body during forward flexion, backward extension, left bending, and left rotation was 79.787 MPa, 36.857 MPa, 37.943 MPa and 96.965 MPa respectively in model C, but was 80.104 MPa, 64.236 MPa, 196.010 MPa and 193.020 MPa respectively in model D. The maximum stress of models C and D was all distributed in the contact area with the internal fixation, and especially during backward extension, left bending, and left rotation, when it was reduced by 42.6%, 80.6%, and 49.8% of model C respectively, compared with that of model D. Conclusions:The improved laminar hook is more consistent with the Chinese anatomized structure of the lamina. Compared with the traditional lamina hook system, the improved lamina hook system can effectively reduce the displacement in all directions and range of motion of lumbar spondylolysis, therefor can significantly reduce the stress of internal fixation and vertebral body and has better biomechanical performance.
5.Application of rice bag in 1.5T MR imaging in maxillofacial
Hong'en LI ; Yuelong LI ; Hanmin XIE ; Peifeng LÜ ; Chengwei LI ; Yihui ZENG
Journal of Practical Radiology 2024;40(2):319-322
Objective To investigate the application value of rice bag in 1.5T MR imaging of maxillofacial frequency selective saturated fat suppression(FS)sequence.Methods Forty-one patients with maxillofacial MR examination were collected.Rapid fast spin echo(FSE)FS T2 routine scan and rice bag FSE FS T2 special scan were used to evaluate and analyze the sequence images of the two kinds by two experienced associate chief physicians in the department according to the Likert 7-point scoring system.The evaluation included FS,magnetic sensitive artifact,motion artifact,and overall image quality.Wilcoxon sign rank sum test was used to analyze the difference of image quality scores,and Kappa consistency test was used to analyze the correlation between two viewers.Results All the 41 patients completed the examination,and the FSE FS T2 plus rice bag group had significantly higher FS,magnetic sensitive artifact,motion artifact and overall image quality than the conventional FSE FS T2 group,with statistical significance(P<0.01).Kappa consistency was good in correlation analysis between the two viewers(Kappa value=0.737-0.877,P<0.01).Conclusion The application of rice bag in the 1.5T MR maxillofacial FS sequence scan has the advantages of good image quality,good FS effect and few artifacts,which can better display the maxillofacial anatomical structure and lesions,and has important clinical application value for the diagnosis of maxillofacial diseases.
6.Finite element analysis of characteristics of spinal cord compression in patients with early cervical spondylotic myelopathy under dynamic position
Chengwei LI ; Yisheng ZHANG ; Zhifei LI ; Yuanming ZHONG ; Jiwen MENG ; Qinqiu LIANG ; Hualong CHEN
Chinese Journal of Tissue Engineering Research 2024;33(33):5257-5264
BACKGROUND:Cervical spondylotic myelopathy is a progressive disease leading to dysfunction in the middle-aged and elderly,and early diagnosis is difficult.In recent years,some clinical scholars have found that dynamic magnetic resonance imaging technology can detect spinal cord compression in a dynamic position earlier,but its specific biomechanical mechanism needs to be clarified. OBJECTIVE:To investigate the biomechanical compression characteristics of early cervical spondylotic myelopathy in hyperextension and flexion position,and to verify the effectiveness of dynamic magnetic resonance imaging in the diagnosis of early cervical spondylotic myelopathy. METHODS:A retrospective analysis was made on the patients who underwent cervical dynamic magnetic resonance imaging in the Department of Orthopedics of First Affiliated Hospital of Guangxi University of Chinese Medicine from January to June 2022.16 subjects were selected and divided into two groups.The pathological group included 8 patients with early cervical spondylotic myelopathy with hypertrophy of ligamentum flavum as the main sign,with 5 male patients and 3 female patients.The normal group included 8 normal degenerative people,with 4 male patients and 4 female patients.All patients were photographed with cervical CT plain scan,magnetic resonance imaging plain scan,and dynamic magnetic resonance imaging plain scan.This study was divided into the following three parts:(1)collect the dynamic magnetic resonance imaging image DCOM data of two groups of subjects,and collect the cervical vertebra CT and neutral magnetic resonance imaging image DCOM data to understand the bone and soft tissue of the two groups of subjects in the neutral position.(2)Based on the DCOM data of magnetic resonance imaging and CT plain scan,the three-dimensional finite element models of lower cervical vertebra(C3-7)of normal degenerative population and early cervical spondylotic myelopathy patients were established by reverse engineering software.The equivalent stress and equivalent elastic strain of the spinal cord and posterior dura were analyzed,and the distribution of stress and strain was observed.(3)After obtaining the stress and strain data,the data between groups were compared to analyze the mechanical characteristics of spinal cord compression caused by early cervical spondylotic myelopathy in a dynamic position and to verify the effectiveness of dynamic magnetic resonance imaging in the diagnosis of early cervical spondylotic myelopathy. RESULTS AND CONCLUSION:(1)When simulating the posterior extension,flexion and neutral position of the lower cervical vertebrae(C3-7)in the two groups,the values of stress and strain in the posterior part of the spinal cord were in the following order:extension>flexion>neutral(P<0.05).The strain values from large to small were as follows:extension>flexion>neutral(P<0.05).(2)Compared with the normal degenerative population model,the equivalent stress and strain of the spinal cord in the pathological group were higher than those in the normal group under two degrees of freedom of flexion and extension(P<0.05).The distribution area of stress and strain in the posterior part of the spinal cord was irregular.(3)In the neutral position,there was no significant difference in the strain value of the spinal cord between the two groups(P>0.05),and the strain distribution was uniform and regular.(4)It is indicated that in the cervical extension position,the dural sac and the posterior part of the spinal cord were compressed and deformed in the early cervical spondylotic myelopathy patients with the hypertrophy of ligamentum flavum as the main sign,and the degree of compression deformation of the spinal cord was significantly higher than that in the anterior flexion position and neutral position.In the neutral position,there were no obvious signs of spinal cord deformation in patients with early cervical spondylotic myelopathy.This study verified the role of dynamic magnetic resonance imaging in the diagnosis of early cervical spondylotic myelopathy from the point of view of biomechanics.
7.Postoperative pulmonary infection in elderly patients with hip fracture:construction of a nomogram model for influencing factors and risk prediction
Haotian WANG ; Mao WU ; Junfeng YANG ; Yang SHAO ; Shaoshuo LI ; Heng YIN ; Hao YU ; Guopeng WANG ; Zhi TANG ; Chengwei ZHOU ; Jianwei WANG
Chinese Journal of Tissue Engineering Research 2024;28(36):5785-5792
BACKGROUND:Establishing a nomogram prediction model for postoperative pulmonary infection in hip fractures and taking early intervention measures is crucial for improving patients'quality of life and reducing medical costs. OBJECTIVE:To construct a nomogram risk prediction model of postoperative pulmonary infection in elderly patients with hip fracture,and provide theoretical basis for feasible prevention and early intervention. METHODS:Case data of 305 elderly patients with hip fractures who underwent surgical treatment at Wuxi Traditional Chinese Medicine Hospital Affiliated to Nanjing University of Chinese Medicine between January and October 2020(training set)were retrospectively analyzed.Using univariate and multivariate logistic regression analysis and Hosmer-Lemeshow goodness of fit test,receiver operating characteristic curve was utilized to analyze the diagnostic predictive efficacy of independent risk factors and joint models for postoperative pulmonary infections.Tools glmnet,pROC,and rms in R Studio software were applied to construct a nomogram model for predicting the risk of postoperative pulmonary infection in elderly patients with hip fractures,and calibration curves were further drawn to verify the predictive ability of the nomogram model.Receiver operating characteristic curves,calibration curves,and decision curves were analyzed for 133 elderly patients with hip fractures(validation set)receiving surgery at the same hospital from November 2022 to March 2023 to further predict the predictive ability of the nomogram model. RESULTS AND CONCLUSION:(1)The postoperative pulmonary infection rate in elderly patients with hip fractures in this group was 9.18%(28/305).(2)Single factor and multivariate analysis,as well as forest plots,showed that preoperative hospitalization days,leukocyte count,hypersensitive C-reactive protein,and serum sodium levels were independent risk factors(P<0.05).The Hosmer-Lemeshow goodness of fit test showed good fit(χ2=4.57,P=0.803).Receiver operating characteristic curve analysis was conducted on the independent risk factors and their joint models mentioned above,and the differentiation of each independent risk factor and joint model was good,with statistical significance(P<0.05).(3)The graphical calibration method,C-index,and decision curve were used to validate the nomogram prediction model.The predicted calibration curve was located between the standard curve and the acceptable line,and the predicted risk of the nomogram model was consistent with the actual risk.(4)The validation set used receiver operating characteristic curve,graphic calibration method,and decision curve to validate the prediction model.The results showed good consistency with clinical practice,indicating that the model had a good fit.The nomogram risk prediction model constructed for postoperative pulmonary infection in elderly patients with hip fractures has good predictive performance.The use of the nomogram risk prediction model can screen high-risk populations and provide a theoretical basis for early intervention.
8.Detection characteristics of the virus during school influenza outbreaks in Linyi City
Chinese Journal of School Health 2024;45(5):723-726
Objective:
To analyze the characteristics of influenza virus detection in an influenza outbreak in schools, so as to provide a strategic basis for the treatment of influenza outbreaks in schools.
Methods:
A total of 1 702 samples were collected from 52 school influenza outbreaks reported in Linyi City in 2021-2022. The samples were divided into 3 types according to different symptoms during the management of the epidemic [group A:influenzalike illness (ILI) group; group B:mild illness group; group C:close contacts group]. Rt-PCR was used to detect influenza virus nucleic acid in the collected samples. The detection rate of influenza virus in the outbreaks was analyzed by χ2 test.
Results:
In total, 1 071 samples (62.93%) tested positive for influenza virus nucleic acid. Among them, 610 out of 726 samples (84.02%) were detected in group A, while 331 out of 634 samples (52.21%) were detected in group B. In group C, 130 out of 342 samples (38.01%) tested positive. The differences were statistically significant (χ2=260.71, P<0.01). In group A, males had a detection rate of 80.83% for influenza virus nucleic acid, compared to 91.36% for females. For group B, the rates were 53.31% for males and 50.87% for females. In group C, males had a rate of 30.72%, while females had a rate of 43.92%. Statistical significance for gender differences was observed only in groups A and C (χ2=12.67, 6.25, P<0.05). According to the days of onset, the detection rates of influenza virus nucleic acid among patients with onset 0-6 days were 56.30%, 74.49%, 89.35%, 86.23%, 69.67%, 62.75%, 34.33%, respectively, and the difference was statistically significant (χ2=128.27, P<0.01).
Conclusions
Mild cases and close contacts are likely key factors contributing to the prolonged emergence of new cases within classrooms during school influenza outbreaks. The progression of influenza symptoms is related to the risk of transmission.
9.Discussion on the core pathogenesis of stagnation as yin-yang poisoning based on the Synopsis of Golden Chamber
Yuxun GAO ; Xipu XIE ; He WANG ; Xiaoqing ZHAO ; Chengwei LI
Journal of Beijing University of Traditional Chinese Medicine 2024;47(4):496-500
This article is based on the core pathogenesis of yin-yang poisoning recorded in the Synopsis of the Golden Chamber and clarifies the characteristics of"yin poisoning"and"yang poisoning"as considered during the Han and Tang dynasties.It is found that the classification criteria for the two are based on the manifestation of syndromes rather than the cold and heat of the pathogenesis.By analyzing the syndrome of yin-yang poisoning in the Synopsis of the Golden Chamber and combining the records with people's understanding of the efficacy of various medicinals in Shengma Biejia Decoction during the Han and Tang dynasties,it is demonstrated that the core pathogenesis is stagnation,mainly reflected in three aspects:accumulation of toxins,stagnation of qi and blood,and stagnation of yang qi.Among these,the degree and location of stagnation of yang qi are the reasons for the difference between yin poisoning and yang poisoning.The disease of yang poisoning is characterized by sufficient yang qi in the body,obstruction of pathogenic factors on the surface,and intense competition between vital qi and evil qi.Therefore,yang stagnation on the surface is more severe and leads to heat symptoms.The disease of yin poisoning is characterized by deficient yang qi in the body,an inability to resist pathogen,and the deepening of evil qi.The yang qi is suppressed by depression and is relatively mild,making it unable to circulate and warm the body,resulting in cold symptoms.Therefore,when treating yang poisoning,ZHANG Zhongjing used medicinals that were pungent,warm and dispersed to relieve the yang depression on the surface.If the yang depression was dispersed,the heat would naturally dissipate.When treating yin poisoning,only internal medicine is used to relieve internal yang qi stagnation,and when yang qi is extended,cold will naturally disappear.In summary,we aimed to enhance our understanding of the efficacy of Shengma Biejia Decoction from the perspectives of promoting the dispersion of toxins,promoting blood circulation,and promoting yang stagnation,in order to provide new ideas for the clinical use of this formula and expand its application scope.
10.The diagnostic value of ultrasound combined with MRI in fetal urinary system abnormalities
Hong'en LI ; Simin HUANG ; Dawei TANG ; Siyue WANG ; Chengwei LI ; Yihui ZENG
Journal of Practical Radiology 2024;40(5):768-771
Objective To investigate the application value of ultrasound combined with MRI in the diagnosis of fetal urinary system abnormalities.Methods The clinical data of 647 cases of fetal urinary system abnormalities suspected by prenatal ultrasound were ana-lyzed retrospectively.All pregnant women underwent MRI examination within 2 days after ultrasound examination.Using pathology and follow-up as the gold standard,the accuracy and imaging features of ultrasound and MRI in detecting fetal urinary system abnor-malities were analyzed.Results Among 600 cases confirmed by pathology and follow-up,the accuracy of MRI,ultrasound and com-bined diagnosis of fetal urinary system abnormalities were 96.50%,96.67%,97.00%,sensitivity were 95.28%,96.23%,98.11%,and specificity were 96.76%,96.76%,96.76%,respectively.There were no significant differences in accuracy,sensitivity,specificity,positive predictive value and negative predictive value between MRI,ultrasound and combined diagnosis(P>0.05).The area under the curve(AUC)of MRI,ultrasound and combined diagnosis of fetal urinary system abnormalities were 0.960,0.965 and 0.974,respectively,with no statistical significance(P>0.05).Conclusion Compared with prenatal ultrasound,MRI also has a higher accuracy(96.50%)in the diagnosis of fetal urinary system abnormalities,and can be used as an important supplement to prenatal ultrasound.


Result Analysis
Print
Save
E-mail