1.Preliminary study on preparation of universal blood type through masking RBC’ s surface antigen with Tween
Hongyu CHEN ; Wei HAN ; Heng JIANG ; Xiaolin YIN ; Hui LI ; Yuqi LI ; Chengshu WU
Journal of Regional Anatomy and Operative Surgery 2015;(1):60-62
Objective To explore the shielding effect that Tween has made on the erythrocyte’ s surface antigen( ABO and D antigen mainly) and the stability of the RBC. Methods Various types red blood cells’ surface antigens were incubated with different concentrations of Tween,then the titers of RBC’ s surface antigen before and after incubation were compared. The erythrocyte’ s function alterations and sta-bility through the morphological obersavation,the osmotic fragility,RBC’ s own hemolysis rate,oxygen saturation( SO2 ) ,routine test of blood as well as the supernatant of free hemoglobin determination were confirmed. Results The masking effect of the Tween-20 on D antigen with the weaken titer keeping above“ +” was better and more stable than that on A,B antigen. The impact on B antigen was a little worse,and A was the worst. The advantaged concentration is about 0. 004%. Besides,the influence of Tween-80’s on B and D antigen was not apparent e-nough. Among all of the concentration,0. 74% and 0. 80% did a relatively better job,which also could keep the weaken titer above “ +”. Conclulsion The shielding effect that Tween has made on the erythrocyte’ s surface antigen( ABO and D antigen mainly) is stable,which keeps above “ +”. The morphology and function of the RBC does not change.
2.Analysis of the efficacy of flow diverter device and traditional stent in the treatment of unruptured ophthal-mic segment aneurysms
Kuihong CHENG ; Gang ZHAO ; Xiwu ZHANG ; Zhuang CHEN ; Che JIANG ; Xiaona WU ; Gaoquan LUO ; Chengshu XU
The Journal of Practical Medicine 2024;40(7):979-983
Objective Discuss the safety and effectiveness of flow diverter device and traditional stent inthetreatment of unruptured ophthalmic segment aneurysms.Methods A retrospective analysis from January 2017 to January 2023 was performed on the clinical data of 70 cases of unruptured aneurysms in the Department of Neurosurgery of Southern Theater General Hospital treated with stent-assisted embolization.According to the type of implanted stents,theywere divided into flow diverter device group(n = 21)and traditional stent group(n = 49),and the postoperative clinical effects and complications of the two groups were compared.Results The two groups of patients followed 3 to 24 months,with an average of(14.4±1.82)months.The results of periopera-tive and follow-up showed that the inclusion rate was higher in the flow diverter device group and the traditional stent group(93.3%vs.87.9%),with no significant difference(P>0.05),and the incidence of perioperative and short-term complications was lower(0 vs.6.1%)in the flow diverter device group than in the traditional stent group,and there currencies rate in the flow diverter device group was lower than that in the traditional stent group(0 vs.6.1%),but the difference was not significant(P>0.05).Conclusion Flow diverter devices and traditional stents in the treatment of unruptured ophthalmic segment aneurysmsare feasible,safe and effective.Preliminary results suggest that the incidence of short-term complications and retreatment is lower after treatment with flow diverter devices,and the operation time is short,but further studies are needed to validate long-term complica-tions in patients.