1.Content determination of tannin in Nodus Nelumbinis Rhizomatis
Shanxin LIU ; Lijing HOU ; Guangqian JIN ; Chengjun GUO ; Ruixue LIANG
China Journal of Traditional Chinese Medicine and Pharmacy 2005;0(02):-
Objective: To establish a method for the content determination of tannin in Nodus Nelumbinis Rhizomatis. Methods: The content of tannin in Nodus Nelumbinis Rhizomatis was detected by molybdophosphate colorimetric method. Results: The content of tannin in Nodus Nelumbinis Rhizomatis from different drugstores varied from 0.2537% to 1.637%. Conclusion: This method was simple, accurate and can be used for the quality control of Nodus Nelumbinis Rhizomatis.
2.Electrochemical Characterizations of Quaternarized Nanodiamond-Myoglobin Modified Electrode
Xiaoling MA ; Chengjun DING ; Pu ZHANG ; Wei GUO ; Hongxia LUO
Chinese Journal of Analytical Chemistry 2014;(9):1332-1337
Through a series of chemical reactions, a kind of quaternary ammonium salt derivative of nanodiamond, ND-CO-NH-CH2-CH2-N ( CH3 ) 3+· I-( QAS-ND ) , was obtained , which was confirmed by FTIR, element analysis experiment and the electrochemistry measurements. Mixed myoglobin ( Mb) and QAS-ND solution was dropped on the surface of the glassy carbon ( GC ) electrode to prepare QAS-ND/Mb/GC modified electrode. In 0. 1 mol/L phosphate buffer solution (PBS) (pH 7. 0), Mb in the membrane exhibited direct electrochemical properties and showed good stability. The electrocatalytic property of the modified electrode toward H2 O2 was investigated, the results showed that the modified electrode could be used as the H2O2 biosensor to achieve fast, accurate detection of H2O2, with a detection limit of 3. 5 mmol/L (S/N=3).
3.Study of the influence of uniform transverse magnetic field on the dose distribution of high energy electron beam using Monte Carlo method.
Shihu YOU ; Yun XU ; Zhangwen WU ; Qing HOU ; Chengjun GUO
Journal of Biomedical Engineering 2014;31(6):1350-1354
In the present work, Monte Carlo simulations were employed to study the characteristics of the dose distribution of high energy electron beam in the presence of uniform transverse magnetic field. The simulations carried out the transport processes of the 30 MeV electron beam in the homogeneous water phantom with different magnetic field. It was found that the dose distribution of the 30 MeV electron beam had changed significantly because of the magnetic field. The result showed that the range of the electron beam was decreased obviously and it formed a very high dose peak at the end of the range, and the ratio of maximum dose to the dose of the surface was greatly increased. The results of this study demonstrated that we could change the depth dose distribution of electron beam which is analogous to the heavy ion by modulating the energy of the electron and magnetic field. It means that using magnetic fields in conjunction with electron radiation therapy has great application prospect, but it also has brought new challenges for the research of dose algorithm.
Algorithms
;
Electrons
;
Humans
;
Magnetic Fields
;
Monte Carlo Method
;
Phantoms, Imaging
;
Radiation Dosage
4.Expressions of Mast Cell Tryptase and Brain Natriuretic Peptide in Myocardium of Sudden Death due to Hypersensitivity and Coronary Atherosclerotic Heart Disease
Jieru SHI ; Chengjun TIAN ; Qiang ZENG ; Xiangjie GUO ; Jian LU ; Cairong GAO
Journal of Forensic Medicine 2016;32(3):161-164
Objective To explore the value of mast cell tryptase and brain natriuretic peptide(BNP)in the differential diagnostic of sudden death due to hypersensitivity and coronary atherosclerotic heart dis-ease.Methods Totally 30 myocardial samples were collected from the autopsy cases in the Department of Forensic Pathology, Shanxi Medical University during 2010—2015. All samples were divided into three groups:death of craniocerebral injury group, sudden death of hypersensitivity group and sudden death of coronary atherosclerotic heart disease group, 10 cases in each group. Mast cell tryptase and BNP in myocardium were detected by immunofluorescence staining and Western Blotting.Results Immunofluo-rescence staining showed that the positive staining mast cell tryptase appeared in myocardium of sudden death of hypersensitivity group and coronary atherosclerotic heart disease group. Among the three groups, the expression of mast cell tryptase showed significantly differences through pairwise comparison(P<0.05); The expression level of BNP in sudden death of coronary atherosclerotic heart disease group were significantly higher than the sudden death of hypersensitivity group and death of craniocerebral injury group(P<0.05). The difference of the expression level of BNP between the sudden death of hypersensitivity group and the death of craniocerebral injury group had no statistical significance(P>0.05).Conclusion The combined detection of the mast cell tryptase and BNP in myocardium is expected to provide help for the forensic differential diagnosis of sudden death due to hypersensitivity and coronary atherosclerotic heart disease.
5.Comparison of drug eluting stent for treatment of intrastent restenosis and de novo lesion
Weiwei ZHU ; Chengjun GUO ; Xianliang LIU ; Hongyong SONG ; Guanqiao DING ; Lin ZHAO
Chinese Journal of Interventional Cardiology 2014;(3):158-162
Objective Compare the efifcacy and safety of drug eluting stent (DES) for treatment of in stent restenosis (ISR) and coronary de novo lesions. Methods Patients treated with DES for ISR and de novo lesions in Beijing Anzhen Hospital between October 2008 and December 2011 were followed up for 1 year. All lesions were divided into ISR and de novo group. Major adverse cardiovascular events (MACE) including all-cause death, myocardial infarction (MI) and clinical target lesion revascularization (TLR) were the primary endpoints. Results The study population consisted of 204 patients in the ISR group and 494 patients in the de novo group. Baseline clinical and angiographic parameters were comparable between the two groups. The rate of diabetic was higher in the ISR group than that in the de novo group (36.6%to 27.1%, P < 0.05). The diameter of coronary artery was smaller in the ISR group than that in the de novo group (2.72±0.36 to 3.08±0.54, P<0.01). The rate of TLR in the ISR group was higher than that in the de novo group (10.7%to 17.2%, P<0.05;14.2%to 21.1%, P<0.05),contributing to higher MACE in ISR group. Conclusions DES implantation is safe and effective for treatment of ISR lesions, but the rate of TLR is higher compared to treatment of de novo lesions.
6.Study of the feasibility and precision in dose calculation with the method of bulk density assignment
Songbing QIN ; Juying ZHOU ; Wei GONG ; Chengjun WU ; Jian GUO ; Long CHENG ; Wei ZHAN
Chinese Journal of Radiation Oncology 2013;(3):247-249
Objective To study investigate the dose accuracy that can be achieved with the method of bulk density assignment.Methods Sixteen cases of nasopharyngeal cancer patients and nineteen cases of esophageal cancer patients who accept radiotherapy in our department were selected.The planning CT images with bulk density assignment to different classes of tissues were applied to calculate the dose distributions,and then the resulting dose volume histograms (DVH) of the tumor and organs of risk were compared with the original treatment plan.The paired t-test was taken for dose comparison between two plans.Results The DVH comparison based on the planning CT and the bulk density assignment CT showed good agreements.With nasopharyngeal cancer patients,differences between the two plans about target and normal tissue were less than 1%.With esophageal cancer patients,the dose differences were less than 2%.Conclusion Preliminary results confirm that the bulk density assignment method can be applied to calculate the dose distributions.
7.Follow-up study on application of radiofrequency ablation combined with magnetic navigation assistance system in elderly patients with atrioventricular node reentrant tachycardia
Kang MENG ; Chengjun GUO ; Rui TIAN ; Huagang ZHU ; Dongping FANG ; Shuzheng LV ; Yundai CHEN
Chinese Journal of Geriatrics 2009;28(1):23-25
Objective To explore the safety, efficacy and 1-year follow-up outcome of radiofrequency ablation combined with magnetic navigation assistance system in elderly patients with atrioventricular node reentrant tachycardia (AVNRT). Methods Forty cases of patients with AVNRT identified by the electrophysiological test were enrolled in the study. Twenty cases were ablated with magnetic navigation system. The other 20 cases underwent the conventional catheters operation. With the cardiodrive, the 8 Frablation magnetic Helios I (Stereotaxis Inc, USA) was advanced to the Koch triangle area from the inferior caval vein (IVC). With the assistance of magnetic navigation (AXIOM Artis, Siemens, Germany), the direction of tip and the advancement or retraction of the catheters were regulated. The success rate, the time of procedure, the fluoroscopy time and the 1-year follow-up outcome were analyzed, and the complications of procedure were recorded. Results Forty cases with AVNRT underwent radiofrequency ablation successfully. In magnetic navigation group, 19/20 cases underwent magnetic catheter operation. The cases who failed to finish magnetic catheter operation underwent successfully conventional catheter operation. There was no perforation complication and no significant statistic difference in the success rate between two groups. No recurring case was found in the two groups 1 year later. The total of fluoroscopy time in magnetic navigation group was more than that in standard ablation group [(16.4±2.7) min vs. (11.1±1.0)rain, P<0.01], but the decreasing trend of fluoroscopy time in magnetic navigation group was showed. The operator's fluoroscopy time in magnetic navigation group was obviously less than that in standard ablation group [(4.5±0.6) min vs. (11.1±1.0) min, P<0.01]. Conclusions The radiofrequeney ablation combining with magnetic navigation system has the similar safety and efficacy to the conventional ablation in elderly patients with AVNRT, but the operator's fluoroscopy time was significantly decreased.
8.Ultrasound-mediated destruction of gene-loaded microbubbles enhanced the transfection of phospholamban antisense RNA into cardiac myocytes
Guozhong WANG ; Jinghua LIU ; Shuzheng Lü ; Chengjun GUO ; Yingchuan ZHANG ; Fei YUAN ; Xiantao SONG ; Yuan ZHOU ; Changjiang GE
Chinese Journal of Ultrasonography 2010;19(10):897-900
Objective To explore whether ultrasound-mediated microbubbles destruction could enhance anti-sense RNA transfection and expression. Methods Phospholamban antisense RNA eukaryon vector PcDNA 4. 1-asPLB was successfully constructed and it was transfected into cardiac myocytes by various methods including calcium phosphate precipitation, ultrasound exposure and ultrasound-mediated microbubbles destruction. The expression of PLB and sarcoplasmic retculum Ca2+ ATPase (SERCA2a) in cardiac myocytes was tested by RT-PCR and western blot. Results The transfection and expression of PcDNA 4. 1-asPLB increased significantly in cells treated with ultrasound-mediated microbubbles destruction compared to other transfer groups( P <0.05). The expression of PLB was inhibited specifically after cardiac myocytes were transfected with PcDNA 4. 1-asPLB. There was no change of PLB expression after cardiac myocytes transfected with PcDNA 4. 1 ( P <0.05). Though the expression of SERCA2a never exhibited any changes after PcDNA 4. 1-asPLB transfection, the PLB/SERCA2a ratio decreased markedly. Conclusions As a highly effective antisense RNA transfer method, ultrasound-mediated microbubbles destruction can enhance the transfection and expression of the PcDNA 4. 1-asPLB significantly. The PcDNA4. 1-asPLB transfection inhibits the expression of PLB and result in decrease of PLB/SERCA2a ratio in cardiac myocytes.
9.Prevalence of depressive and anxiety disorders in cardiovascular outpatients from 14 tertiary general hospitals of 5 Chinese cities.
Guo LI ; Ronghuan JIANG ; Chengjun GUO ; Meiyan LIU ; Lijun ZHANG
Chinese Journal of Cardiology 2014;42(12):1035-1038
OBJECTIVETo explore the prevalence of depression and (or) anxiety disorders among cardiovascular outpatients of tertiary general hospitals of five Chinese cities.
METHODSA hospital-based cross-sectional survey was conducted in the cardiovascular out-patient departments of 14 tertiary general hospitals in five Chinese cities. The patients aged 18 years and over were recruited consecutively, who were conscious and with informed consent, and can finish the questionnaire independently. All the subjects were screened with Hospital Anxiety Depression Scale (HADS). The subjects with HADS score of 8 and over were interviewed and diagnosed by psychiatrists using mini international neuropsychiatric interview (MINI). The physicians made the diagnosis and management without knowing the results of MINI and HADS score. Subjects who refused MINI were defined as the case of loss of follow-up.
RESULTSA total 2 123 subjects were included in the survey. The adjusted prevalence rate of depressive and anxiety disorder was 4.05% (86/2 123), the depressive and/or anxiety disorder was 14.27 % (303/2 123), depressive and anxiety disorder and mixed depressive or anxiety disorder was 14.37% (305/2 123) according to MINI. The adjusted prevalence of lifetime depressive and anxiety disorder was 5.37% (114/2 123), depressive and/or anxiety disorder was 16.91% (359/2 123), depressive and anxiety disorder and mixed depressive-anxiety disorder was 17.00% (361/2 123).
CONCLUSIONThere is a high prevalence of depressive and anxiety disorder among cardiovascular outpatients from tertiary general hospitals in China. Therefore, doctors must pay attention to this disorder and try to reduce the impact of this disorder in cardiovascular patients.
Adult ; Anxiety Disorders ; epidemiology ; Asian Continental Ancestry Group ; Cardiovascular Diseases ; psychology ; China ; epidemiology ; Cities ; Cross-Sectional Studies ; Depressive Disorder ; epidemiology ; Disease Management ; Hospitals ; Hospitals, General ; Humans ; Outpatients ; Physicians ; Prevalence ; Surveys and Questionnaires
10.Application of domestic snare in retrograde percutaneous coronary intervention for coronary chronic total occlusion lesions
Lin ZHAO ; Zening JIN ; Xiaojiang ZHANG ; Dongfang HE ; Yawei LUO ; Xiantao SONG ; Jinghua LIU ; Chengjun GUO ; Guihua LI ; Lei WANG ; Bing WANG ; Shaoqing CHEN ; Hongtao SUN ; De LYU
Chinese Journal of Interventional Cardiology 2017;25(4):197-201
Objective To evaluate the safety and efficiency of domestic snare applied during retrograde percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) lesions.Methods A total of 27 patients who underwent retrograde PCI for CTO and used domestic snare during the procedure were enrolled in our study from March 2012 to November 2016.Clinical data, angiographic characteristics and PCI details were collected.Clinical data, characteristics of CTO lesion, effect of the domestic snare and snaring time were retrospectively analyzed.Special complications related to the domestic snare and major adverse cardiovascular events (MACE) were also documented.Results Domestic snare was used in all the procedures, which included facillitating the micro-catheter to pass through the CTO lesions in 6 patients and assisting the RG3/rotational guide-wire externalization in all the 27 patients.Mean snaring time was 3.5±5.4 minutes.Stents were successfully implanted in 26 patients except in 1 patient who failed to receive stent implantation for severe coronary calcification.No complications including coronary dissection, fracture of guide-wire and unreleased snare happened during the procedures and no MACE occurred during hospitalization.Conclusions Domestic snare facilitates retrograde micro-catheter crossing CTO lesions and retrograde guide-wire entering the guiding catheter and externalization.It is a simple, safe and efficient method.