1.Prevention of childhood tuberculosis
International Journal of Pediatrics 2011;38(6):532-535
In recent years the incidence rate of tuberculosis (TB) has gone up.It was estimated that 1/3of people had asymptomatic latent tuberculosis infection globally.The current widespread use of Bacillus calmetteguerin (BCG) vaccine program against tuberculosis in children has a good preventive effect,but due to the limited duration of the immune responses induced by BCG,there also had situation of prevent failure,so researchers begin to explore new TB vaccines,such as live attenuated mutant strains,subunit vaccines and DNA vaccines,and achieved certain results.For the pure protein derivative tuberculosis skin test positive and immunosuppressed children,in addition to active immunization would also need anti-TB medicine for chemoprophylaxis.
2.Selection of CR and DR
Zhiqiang HE ; Linghong ZHOU ; Chaomin CHEN
Chinese Medical Equipment Journal 1989;0(03):-
Selection of CR and DR is very important for digital radiology departments in modern hospitals. This paper discusses the components of CR and DR as well as their technical requirements.
3.Variational Model on Wavelet Domain for PET/CT Image Fusion
Qian NI ; Chaomin CHEN ; Linghong ZHOU
Chinese Medical Equipment Journal 1993;0(05):-
Objective To find a new algorithm for PET/CT image fusion.Methods A variational model was used based on the wavelet transform.Firstly,PET and CT images were decomposed using wavelet transform.Then,images in approximate channel and detail channel were fused according to the two proposed assumption.Finally,decomposed images were synthesized to form fused image.Results Compared with the results form MATLAB wavelet fusion toolbox,the experimental results showed that the new variational image fusion model could provide more accurate result for target location in radiotherapy planning.Conclusion According to experiments,the new algorithm can reach good results and meet requirement of clinical demands.
4.Research of the refrigeration system of a new field portable blood refrigerator
Chaomin CHEN ; Lei TONG ; Qiuwu HUANG ; Guangjie CHEN
Chinese Medical Equipment Journal 2003;0(12):-
This paper develops the refrigeration system of a new field portable b lood refrigerator. Based on inverse heat leak test, the hardcore of thermoelectr ic refrigerator and the match of the system are determined, and several key fact ors of refrigeration effect are analyzed. In the aspects of framework, size and noise, the blood refrigerator with a thermoelectric refrigeration system is bett er than the traditional one with a compress refrigeration system.
5.A Method for Calculating Scatter Dose of Irregular Fields
Haoyu JIN ; Qingwen LV ; Chaomin CHEN ; Linghong ZHOU ; Guangjie CHEN
Journal of Practical Radiology 2001;0(07):-
Objective To find a method for calculating the scatter dose of irregular fields. Methods The original Day function was improved to vary with radiation depth, and the improved Day function was used for irregular fields to calculate scatter dose. Results The accuracy was greatly improved by making Day function depend on radiation depth, and the error was within 1.5%. Conclusion This method can be used to calculate the scatter dose of irregular fields as well as rectangular fields.
6.Intraarterial Chemotherapy Followed by Radical Hysterectomy for Locally Advanced Cervical Cancer
Qi CHEN ; Zhengmin WANG ; Dehui WANG ; Chaomin ZHOU
Fudan University Journal of Medical Sciences 2000;27(3):218-221
PurposeTo evaluate the curative effect and possibility of the intraarterial chemotherapy followed by radical hysterectomy for locally advanced cervical cancer. Methods59 patients with FIGO stage lb-IV cervical cancer were enrolled and the tumor size with stage lb and Ua must be more than 4 cm. Treatment consisted of bilateral internal iliac artery infusion of cisplatin 80 rog, 5-Fu 1 500 rog, and AT1258 60 mg for 1 - 3 courses separated by 3 weeks. The tumor size was measured by vagina ultrasonic and CT before and after chemotherapy to calculate the shrunk size percent. All patients underwent radical hysterectomy. Patients with disease in the vagina, parametrium, pelvic lymphnodes or microscopic tumor emboli were followed postoperative pelvic irradiation. Results59 patients underwent 122 courses of intraarterial chemotherapy for 1 - 3 courses each. The total response rate was 95 %. Complete response (CR) was achieved in 18 of 59 patients (31%) ,while a partial response (PR) was noted in 38 (64%) and stable disease (SD) in 3 (5% ). No patient had progressive disease. 14 patients with pelvic lymphnode metastasis were all found to have PR and SD. No patient had lymphnode metastasis in CR. Of 18 patients with CR, 17 patients had not recurrence. Only one patient with stage lla recurred 20 months after operation. But he also cured. All 18 patients with CR were living free of disease. But 3 in 38 patients with PR died and 3 patients with SD were all died. There were no severe complications related to intraarterial chemotherapy and radical hysterectomy. Conclusionslntraarterial chemotherapy before operation can shrink tumor size, decrease the lymphnode metastasis. It is feasible in helping elevating cure rate of patients with locally advanced cervical cancer who are at high risk for failure with conventional treatment.
7.Correlations between coagulation function and pediatric critical illness score in children with severe pneumonia
Lumin CHEN ; Chengyi WANG ; Chaomin SONG ; Qian ZHENG
Chinese Pediatric Emergency Medicine 2013;20(4):380-382
Objective To investigate the relationship between coagulation function and pediatric critical illness scores (PCIS) in children with severe pneumonia.Methods The PCIS were collected in 152 children with severe pneumonia (pneumonia group) admitted in our pediatric intensive care unit from Jan 2010 to Jul 2011,and 20 healthy children in the same period were selected as the healthy control group.The coagulation indicators of children in both groups were detected and the relationship between coagulation markers and severity of pneumonia was analyzed.Results There were significant differences in platelet count,fibrinogen,D-Dimer,soluble P-selectin between pneumonia group and healthy control goup [(185.74 ±116.26) × 109/L vs (287.10 ±90.01) × 109/L,(3.51 ±0.50) g/L vs (3.15 ±0.15) g/L,(1.39 ±2.18) μg/ml vs (0.36 ± 0.07) μ g/ml,(110.07 ± 83.47) ng/ml vs (33.74 ± 9.47) ng/ml,P < 0.05].There were positive correlation between soluble P-selectin,D-Dimer and severity of disease and negative correlation between platelet count and severity of disease in children with severe pneumonia.Regression equation:y =1.154 +0.003 × soluble P-selectin + 0.089 × D-Dimer-0.001 × platelet count (P < 0.05).As the children's critical condition getting worse,soluble P-selectin and D-Dimer levels increased (P < 0.05).Hatelet count showed no significant difference between critical group and extremely critical group,which was significantly lower than that in non-critical group (P < 0.05).Conclusion Soluble P-selectin,D-Dimer,and platelet count are associated with the severity of pneumonia.The children with severe pneumonia are easy to have coagulation disturbance.
8.Research on control circuit of a new CT simulation laser positioning system
Fuxi LIAO ; Chaomin CHEN ; Zihai XU ; Jinqin ZENG ; Xiaoxi ZHENG
Chinese Medical Equipment Journal 1989;0(02):-
CT laser simulation positioning system is a necessary auxiliary device for radiotherapy. Its main purpose is to position patients by simulating different kinds of treatment machine. In order to demarcate the mark of the iso-center, it is common to use the laser positioning device to indicate the iso-center. The kernel technology of the laser positioning system is the controlling of the step progress motor by using the MCS, which is to control the movement of step progress motor using the wheel of the motor. This design uses MCS-51 to control step progress motor by the way of exporting the rectangle wave form through I/O port of 8255 chip. The system configuration is simple, the operation is convenient and the positioning is precise.
9.Research and experiment of compensator made by split method for static intensity-modulated radiation therapy
Zihai XU ; Chaomin CHEN ; Linghong ZHOU ; Fuxi LIAO
Chinese Medical Equipment Journal 2004;0(07):-
Objective To help the hospitals at all levels in China to realize IMRT by adding the accurate location equipments and TPS based on the existing general radiation therapy from research of the new method for static Intensity-modulated radiation therapy. Method Based on the controlled technique of CRT, a new split method for fabricating the three-dimensional physics compensator to achieve the IMRT was developed. Results The Experiment manifested that the compensator fabricated by the way could make the high dosage shape of target in accordance with the form of tumor and could adjust the distribution of the dosage according to remedy requirement. Conclusion The method is simple and feasible, and has brilliant clinical prospective and popularized significance.
10.Development of Long Pulse YAG Laser Treatment Machine
Zhenyu WANG ; Linghong ZHOU ; Chaomin CHEN ; Anyang WEI
Chinese Medical Equipment Journal 1989;0(03):-
Objective To develop a laser treatment machine for the benign prostatic hyperplasia(BPH),which can both avoid the transurethral resection symptoms(TURS) and rapidly remove the big BPH.Methods The machine adopted a long plus laser with 80W average power and 1000W peak value power in order to rapidly vaporize the neoplasm.Because of its high power,short operation time and small thermal penetraction depth,it could avoid the post-operation edema of the organ is resulted from the concretion of traditional continuous-wavelength YAG laser.The control system based on AT89C51 dominated the laser power,and meanwhile,it monitored the process to protect the machine.It was connected with the Hospital Information System(HIS) via RS232.Results The chicken breast tissues were irradiated with the sample machine under water,and the groove irradiated by laser was 4mm in width and 2.5mm in depth with the irradiation speed of 5mm/s.The arbonation of tissue surface was slight and the thermal damage to the adjacent tissues was the minimal.Conclusion This machine can rapidly vaporize the neoplasm with the minimal thermal damage to the adjacent non-irradiated tissues.It is desirable for the treatment of big BPH.