1.Comparison of hip arthroplasty and internal fixation for the treatment of intertrochanteric fractures
Binggang XIONG ; Wenwei XIE ; Hangang YAO ; Shengcheng LI ; Deyun LIAO ; Zaixue LI ; Minghua LI ; Changyao SU
Chinese Journal of Primary Medicine and Pharmacy 2008;15(7):1137-1139
Objective To compare the effect of hip artificial replacement and DHS internal fixation for the treatment of intertrochanteric fracture, and investigate the difference of the two method. Methods Eighty-six pa- tients with intertrochanterie fracture patients were treated with hip arthroplasty, and dynamic hip screw. The pa- tients were followed up for 6 months, and compared the operation rime, blood loss, postoperative complications, sur- vival rate, postoperative hip function score and lose situation. Results There was no significant difference in opera- tion time,blood loss,postoperative complications,in local symptoms hip varus deformation occured in the DHS inter- hal fixation because lag screw cut-our and the collapse of the medial cortex, hip and thigh pain oecured in artificial re- placement,hip function score dropped 9.5 % in DHS and 9.2% in artificial replacement. Conclusion For elderly patients, eomminuted fracture and osteoporosis, and other types of unstable intertrochanteric fracture patients, the primary purpose of surgery is to provide to patients more activities of the early conditions,so hip arthroplasty can be used to the treatment of intertrochanteric fracture,as a reasonable replacement surgery.
2.Clinical analysis on treatment of lateral clavicular fracture and acromioclavicular joint dislocation with clavicular hook plate
Wenwei XIE ; Shengcheng LI ; Xiangzi FANG ; Hangang YAO ; Deyun LIAO ; Binggang XIONG ; Changyao SU
Chinese Journal of Postgraduates of Medicine 2006;0(18):-
Objective To analyze the effect of clavicular hook plate(CHP) in treating distal clavicular fracture and acromioclavicular joint dislocation. Methods Eighteen patients with distal clavicular fracture(NeerⅡ) and acromioclavicular joint disclocation(Tossy Ⅲ) were treated by CHP. Results Sixteen patients were observed after operation,according to Lazzcano curative effect standard, fifteen cases were excellent, take 93.75 percent,1 case was good, with 6.25 percent, the excellent and good rates were 100.00 percent. The phenomenon such as the steel plate fracture,loose,escape hook and acromioclavicular joint re-dislocation were not happened. Conclusion CHP is an effective,scientific and convenience way for distal clavicular fracture and acromioclavicular joint dislocation,it worth being promoted.