1.Study on Quantitative Structure-Retention Relationships of Microemulsion Electrokinetic ChromatographyUsing Phospholipids as Surfactant
Jing SONG ; Yuan ZHENG ; Changhong HUO ; Jianfang LIU
Chinese Journal of Analytical Chemistry 2017;45(5):654-661
Some new types of microemulsion using phospholipids as the main surfactant were prepared for electrokinetic chromatography and the quantitative structure-retention relationship of neutral solutes in these microemulsion electrokinetic chromatography (MEEKC) systems was studied by solvation parameters model.By using dynamic coating capillary, and with dimethyl sulfoxide (DMSO) and dodecyl benzene as the marker of electroosmotic flow and microemulsion droplets, a total of 17 kinds of stable microemulsions containing soybean phospholipids or other surfactants were prepared and the linear salvation energy relationship equations were developed for these MEEKC systems with 26 small neutral compounds.The coefficients of linear solvation energy relationship (LSER) equations were used to evaluate the similarity of two MEEKC systems.Results indicated that LSER characteristics of phospholipids-MEEKC systems were similar to those of other microemulsion systems.The volume and hydrogen bond basicity of solutes were mostly contributed to the retention in MEEKC.The different types and concentration of oil phase had no evident influence on the retention.
2.Therapeutic effect of autologous bone marrow mononuclear cell transplantation on diabetic lower extremity vascular disease and its relation with serum level of HGF
Yu GAN ; Lili YU ; Tienan LI ; Changhong ZHENG
Chinese Journal of Practical Internal Medicine 2001;0(03):-
Objective To probe therapeutic effect of autologous bone marrow mononuclear cell transplantation on diabetic lower extremity vascular disease and its association with serum level of HGF.Methods 79 diabetic lower extremity vascular disease cases was divided into regular treated group (group A):40 cases,80 affected limbs;autologous bone marrow mononuclear cell transplantation treated group (group B):39 cases,78 affected limbs.And the therapeutic effect as well as serum level of HGF was evaluated after 6-month treatment.Results (1)After one-week treatment,there was significant statistically with limb pain,cold feeling of affected limbs,skin temperature,serum level of HGF among group B compared with pretreatment and group A(P
3.Effect of intravenous Gd-DTPA on 3.0T MR spectroscopy prescan of different organs
Shaoheng TAN ; Changhong LIANG ; Junhui ZHENG ; Li XU ; Zhonglin ZHANG
Chinese Journal of Medical Imaging Technology 2010;26(3):571-573
Objective To evaluate the effect of intravenous Gd-DTPA on 3.0T proton MR spectroscopy (MRS) water suppression and shimming. Methods Prospective study of proton MRS was performed with GE Signa Excite HD 3.0T system and eight-channel phased-array coils with PRESS sequence (head, liver and kidney, respectively). Routine auto prescan program was operated to record full width half maximum (FWHM) and water suppression (WS%). Routine scan was performed after injection of Gd-DTPA, then prescan program was reoperated to record FWHM and WS%. The data of FWHM and WS% in head, liver and kidney were compared between before and after injection of Gd-DTPA with the Wilcoxon matched pairs signed test. Results WS% of spectroscopy of head and liver after administration of Gd-DTPA decreased significantly (T_+=12, T_-=66, P=0.02; T_+=0, T_-=45, P=0.007). The effect of shimming of kidney after administration of Gd-DTPA was poor (T_+=0, T_-=435, P<0.001) and WS% of spectroscopy of kidney after administration of Gd-DTPA decreased significantly (T_+=0, T_-=435, P<0.001). Conclusion WS% of spectroscopy in head, liver and kidney can be impacted negatively by Gd-DTPA. Gd-DTPA has great influence on shimming of spectroscopy of kidney, but has little influence on shimming of spectroscopy of head and liver. It is better to acquire MRS data before administration of contrast medium in kidney.
4.Effect of shimming on water suppression and metabolites concentrations of 3.0T proton spectrum
Shaoheng TAN ; Changhong LIANG ; Junhui ZHENG ; Li XU
Chinese Journal of Medical Imaging Technology 2010;26(2):369-371
Objective To observe the effect of full width half max (FWHM) on spectra signal-to-noise ratio (SNR), NAA/Cr, Cho/Cr and water suppression at 3.0T MR. Methods GE Signa Excite HD 3.0T MR scanner with 8 channel phrased-array head and neck coil was used. The respective study of liver 1H-MRS was performed using PRESS sequence. A total of 49 spectrums were obtained with parameters of TR 1500 ms, TE 30 ms, NSA 128. FWHM and water suppression were recorded automatically and the subjects were divided into better shimming group (FWHM<10 Hz) and worse shimming group (FWHM≥10 Hz). Independent t test was used to analyze the Cr_SNR, NAA/Cr, Cho/Cr, water suppression and volume of interest (VOI). Results Compared with worse shimming group, better shimming group could provide better Cr_SNR (t=5.976, P<0.001), higher NAA/Cr (t=2.469, P=0.017), lower Cho/Cr (t=-4.460, P<0.001) and smaller VOI (t=3.862, P<0.001). Conclusion When single voxel proton spectroscopy of head is adopted with 3.0T MR, small VOI is easy to achieve effective shimming, and better shimming is helpful to improve SNR, the ratio of main metabolites as well as water suppression.
5.Target-controlled infusion of etomidate and remifentanil for endobronchial ultrasound-guided transbronchial needle aspiration
Xin WANG ; Yu REN ; Zheng XU ; Zhiming TAN ; Changhong MIAO
Chinese Journal of Anesthesiology 2012;32(3):317-319
Objective To investigate the effectiveness of target-controlled infusion (TCI) of etomidate and remifentanil for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA).Methods Sixtynine ASA Ⅰ or Ⅱ patients of both sexes,aged 35-71 yr,weighing 41-83 kg,scheduled for elective EBUS-TBNA,were randomly divided into 3 groups ( n =23 each).In group Ⅰ,anesthesia was induced with TCI of propofol and iv injection of fentanyl 4 μg/ml,and the target plasma concentration (Cp) of propofol was set at 3-4 μg/ml.In group Ⅱ ,anesthesia was induced with TCI of propofol ( Cp 3-4 μg/ml) and remifentanil ( Cp 5 ng/ml).In group Ⅲ ,anesthesia was induced with TCI of etomidate (Cp 0.3-0.4 μg/ml) and remifentanil (Cp 5 ng/ml).After the patients lost consciousness,laryngeal mask airway was inserted to perform mechanical ventilation.PETCO2 was maintained at 30-40 mm Hg.BIS value was maintained at 40-60.The use of vasoactive agents (perdipine,ephedrine,atropine and esmolol) and occurrence of bucking during operation,emergence time,and the occurrence of nausea and vomiting within 24 h after operation were recorded.Blood samples were collected from the femoral vein at 30 min before induction,at the end of operation and at 24 h after operation for determination of the plasma cortisol concentration.Results The incidence of bucking and nausea and vomiting was significantly lower,the emergence time was significantly shorter,and the number of patients who needed vasoactive agents during operation was significantly smaller in groups Ⅱ and Ⅲ than in group Ⅰ ( P < 0.05).The number of patients who needed vasoactive agents during operation was significantly smaller in group Ⅲ than in group Ⅱ (P <0.05).Compared with groups Ⅰ and Ⅱ,the plasma cortisol concentration was significantly decreased at the end of operation in group Ⅲ (P < 0.05).There was no significant difference in the plasma cortisol concentration at each time point between groups Ⅰ and Ⅱ (P>0.05).Conclusion TCI of etomidate (Cp 0.3-0.4 μg/ml) and remifentanil (Cp 5 ng/ml) can provide satisfactory anesthesia for EBUS-TBNA with few adverse effects.
6.Exploration of factors influencing shimming and water suppression on hepatic 1H-MR spectroscopy in vivo on 3.0 T
Changhong LIANG ; Li XU ; Zaiyi LIU ; Yanhai CUI ; Chunling LIU ; Junhui ZHENG ; Qiongxin ZENG
Chinese Journal of Radiology 2009;43(7):739-742
Objective To characterize the clinical factors which influence water suppression and auto-shimming line width for liver 3.0 T 1H-MRS.Methods Fifty-seven cases with liver 1H-MR spectroscopy(1H-MRS) were retrospectively studied, including chronic type B hepatitis (n=5), fatty liver (n=14), chronic type B hepatitis combining fatty liver (n=3) and normal situation (n=35).Independent t test was used to characterize the difference of general condition (height, weight, body mass index etc.) between different water suppression effect groups and between different shimming effect groups.Using Chi-square test to analyze whether water suppression rate and auto-shimming line width between fatty liver groups and non-fatty liver exist significance difference .Results By comparing WS ≥90% (n=47)group with WS < 90% (n=10) group, the former showed smaller average height[(164.7±8.0) and (170.5±3.7) cm respectively], weight[(61.8±10.4) and (73.4±5.4) kg respectively], BMI [(22.7±3.2) and (25.2±1.3)kg/m2 respectively]and LW[(17.7±3.7)and(24.6±6.3) Hz respectively]than the latter (t=-3.488,-3.415,-4.002 and-3.327, P < 0.05).By comparing LW 20 Hz (n=41) group with LW 20 Hz (n=16) group, the former showed better water suppression rate [(93.0±2.7)% and (86.1±8.5)% respectively]than the latter(t=3.213,P <0.05), whereas larger weight[(62.2±11.6) and (68.1±6.1)kg respectively]and BMI[(22.8±3.4) and (24.2±1.9)kg/m2 respectively](t=-2.516,-2.024,P <0.05).LW≤20 Hz in the fatty liver and non-fatty liver group was 7/17 and 34/40, respectively (X2=11.347, P < 0.05).WS < 90% in the fatty liver and non-fatty liver group was 10/17 and 0/44, respectively (X2=28.536, P < 0.05) .Conclusion Hepatic steatosis exerts an adverse effect in water suppression and shimming.
7.Optimization of scan parameters for proton MR spectroscopy on liver in vivo at 3.0 T
Changhong LIANG ; Li XU ; Zaiyi LIU ; Junhui ZHENG ; Shuixing ZHANG ; Qiongxin ZENG ; Shaoheng TAN ; Yuanqiu QIAO
Chinese Journal of Radiology 2009;43(11):1191-1195
Objective To characterize the effect of the ~1H-MRS scan parametem, including the type of coil, TE,NSA and VOI, on shimming, water suppression, spectral signal to noise ratio(SNR)and the stability of the baseline of liver in vivo. Methods ~1H-MRS of liver in vivo was performed prospectively on GE Signa Excite HD 3.0 T system in 46 volunteers. Point-resolred spectroscopy(PRESS)sequence with built-in body coil and eight-channel torso phased-array coils was applied. After the localized scan,the first PRESS sequence with a TR of 1500 ms,TE of 30 ms. VOI of 2 cm×2 cm×2 cm and NSA of 64 times was acquired using eight-channel torso phased-array coils.(The first PRESS sequence parametem was deemed as A).Then,the sequence was repeated with alteration of the three parameters including the type of coil,TE and size of VOI.(Changed parameters deem as B).The data were analyzed with the Wilcoxon matched pairs signed test.0 mark:A is similar to B,1 mark:A better than B,-1 mark:A worse than B.Results SNR(-1 mark 0 pair,0 mark 1 pair,1 mark 10 pair,Z=-3.162,P=0.002)was better in data(n=11)with eight-channel torso phased-array coils(A)than that with the built-in body coil(B),but the autoshimming line width with eight-channel torso phased-array coils were inferior to those with built-in body coil (-1 mark 8 pair,0 mark 2 pair,1 mark 1 pair,Z=-2.511,P=0.012).SNR was better in data(n=13)with TE of 30 ms(A)than that at the sequence with TE of 90 ms(B)(-1 mark 2 pair,0 mark 0 pair,1 mark 11 pair,Z=-2.496,P=0.013).whereas baseline stability was,poorer in the former(-1 mark 10 pair,0 mark 2 pair,1 mark 1 pair,Z=-2.333,P=0.020).SNR at the sequence(n=10)with VOI of 2 cm×2 cm×3 cm(B)was better(-1 mark 6 pair,0 mark 4 pair,1 mark 0 pair,Z=-2.449,P=0.014)than that at the sequence(n=29)with VOI of 2 cm ×2 cm × 2 cm(A),but poorer(-1 mark 0 pair,0 mark 5 pair,1 mark 5 pair,Z=-2.041,P=0.041)auto-shimming line width was shown. By comparison the sequences with NSA of 128 times(B)and NSA of 64 times(A),the former could provide better spectrum SNR(-1 mark 21 pair,0 mark 7 pair,1 mark 1 pair,Z=-4.264,P=0.000).Conclusion It is more easy to achieve a homogeneous bo magnetic field using a small size of VOI and builtin body coli.The sequence with VOI of 2 cm ×2 cm ×3 cm.NSA of 128 times is recommended for clinical use. Increase VOI and NSA are helpful to improve SNR. Longer TE is helpful to improve baseline stability.
8.Effect of Tetramethylpyrazine Combined with Cisplatin on Expression of Arresten, Integrin α1β1,VEGF of Lewis Lung Cancer Mice
Yafang ZHU ; Zhihua ZHANG ; Zhilin ZHANG ; Xiulong ZHANG ; Jianhua TANG ; Yingjuan ZHENG ; Changhong ZHANG
Herald of Medicine 2016;35(6):583-587
Objective To investigate the inhibition mechanism of tetramethylpyrazine combined with cisplatin on angiogenesis in Lewis lung cancer mice and to observe the mechanism of Arresten on angiogenesis in lung cancer. Methods The model of Lewis lung adenocarcinoma mouse xenograft was established in this work, and 40 mice were randomly divided into 4 groups: 0.9% sodium chloride solution group(NS group), tetramethylpyrazine group(TMP group), cisplatin group(DDP group), tetramethylpyrazine plus cisplatin group(TMP + DDP group), 10 mice in each group.Mice in NS group were given 0.2 mL of 0.9% sodium chloride solution, mice in DDP group were given 0.2 mL of 2 mg.kg-1 of cisplatin, mice in TMP group were given 0.2 mL of 100 mg.kg-1 of tetramethylpyrazine, mice in TMP+DDP group were given 2 mg.kg-1 of cisplatin and 100 mg.kg-1 of tetramethylpyrazine, each 0.1 mL .Tumor size was measured every day to calculate the tumor volume.The mice were sacrificed to stripp the subcutaneous tumor after continuous medication. The expressions of Arresten, integrin α1β1 and VEGF were determinated by immunhistochemistry and Western blotting. Results The tumor growth of NS group was the fastest and TMP+DDP group was the slowest. Compared with NS group, the expression of Arresten in the other three groups was increased( P<0.01) , and the TMP+DDP group exhibited the highest expression;at the same time, integrin α1β1 , VEGF in the other three groups was decreased(P<0.01), and the TMP+DDP group exhibited the lowest expression.The expression of integrinα1β1 and VEGF was negatively related to Arresten, and the expression of integrin α1β1 was positively correlated with VEGF. Conclusion TMP can inhibited the growth of Lewis lung carcinoma and angiogenesis. Moreover, in combination with cisplatin, TMP can also improved the effect of chemotherapy and then the survival state of mice. The mechanism of action, which TMP suppress tumor angiogenesis may be through improving Arresten and inhibiting integrin α1β1 and VEGF. And the action mechanism of Arresten may be implemented by inhibiting the expression of VEGF by incorporation with integrinα1β1 or by itself to inhibit the expression of VEGF.
9.The effects of reproducibility of apparent diffusion coefficient measurements obtained with respiratory motion compensation techniques
Guimian ZHONG ; Zhiming XIANG ; Qianwen LIANG ; Zhu AI ; Jianke LIANG ; Hexu ZHENG ; Changhong LIANG
Chinese Journal of Radiology 2016;50(9):686-690
Objective To evaluate the reproducibility of normal liver ADC measurements by different respiratory motion compensation techniques. Methods A total of 31 young healthy volunteers who are 20 to 40 years old without any hepatic diseases were selected to research. Each volunteer underwent liver DWI twice in 24 hours with the same parameters and location. The imaging was performed with free-breath(FB), breathhold(BH), rspiratory-triggered(RT)and navigator-triggered(NT)techniques, and the ADC values of the left hepatic lobe and right hepatic lobe (upper, middle and lower) was acquired with two scans. Analysis the the ADC values of various anatomic locations of liver with two-way analysis of variance of randomized block design. Reproducibility of ADCs was assessed with the Bland-Altman method. Analysis of variance and paired-sample t test was used to assess ADCs from both right and left liver lobe among the four techniques. Result The ADC values acquired from the four techniques were significant differences (P<0.01),and the ADC values of the right lobe were less than the left lobe's(P<0.01). It showed a trend to decrease moving from superior to inferior levels in both left and right lobes, and the ADC values among The middle and lower were significant differences (P<0.01). The limit of agreement of ADC of twice imaging among the four techniques were as follow: the right lobe was less than the left lobes, and the breathhold was less the others. As the result, reproducibility in the right liver lobe was better to that in the left and the reproducibility with breathhold was better than the other respiratory motion compensation techniques. Conclusions Both anatomic location and DWI technique influence the liver ADC measurements and their reproducibility. The reproducibility of BH is the best.
10.Feasibility of tube current modulation based on the chest circumference in coronary CT angiography
Yanhai CUI ; Meiping HUANG ; Jinglei LI ; Hui LIU ; Changhong LIANG ; Junhui ZHENG
Chinese Journal of Radiological Medicine and Protection 2014;34(10):783-786
Objective To establish a function model to modulate the tube current according to the chest circumference at Coronary CTA scan,and to evaluate the feasibility of using the function model individually.Methods Sixty-eight consecutive patients who underwent thoracic scan with automatic current modulation were studied to establish a function model of tube current and chest circumference.The other 64 consecutive patients underwent coronary CTA scan using the new function model.The image quality was scored,and the noise,tube current and radiation dose were recorded and statistically evaluated.Results The POW function model was the best one to adjust tuber current to the chest circumference (R2 =0.691,P < 0.05).The mean image quality score,noise,tube current,radiation dose (CTDIvol) and dose-length product (DLP) were (3.38±0.72) scores,(31.02 ±3.97) HU,(390.63± 89.30) mA,(34.83±10.72) mGy,(751.67 ±175.16) mGy·cm,respectively.Conclusions Tube current modulation based on the chest circumference would be feasible to reduce the radiation dose individually in coronary CT angiography.