1.Effect of dexmedetomidine on tracheal extubation response in patients undergoing thyroid surgery after general anesthesia
Lijing MA ; Can MA ; Xianfeng REN ; Changfu LIN
Chinese Journal of Postgraduates of Medicine 2012;35(3):11-13
ObjectiveTo investigate the effect of dexmedetomidine on tracheal extubation response in patients undergoing thyroid surgery after general anesthesia.Methods Forty-two patients who ASA classification Ⅰ - Ⅱ,were performed thyroid surgery under total intravenous anesthesia.They were divided into dexmedetomidine group and control group by random number table with 21 cases each.Both groups patients anesthesia induction and maintenance with the same methods,dexmedetomidine group patients at 15 min before anesthesia induction with venous infusion dexmedetomidine 0.6 μ g/kg(finished 10 min infusion),followed by 0.4 μ g/(kg · h) continuous infusion,control group patients with pump equivalent in 0.9% sodium chloride injection in the same way.Systolic blood pressure (SBP),diastolic blood pressure (DBP) and heart rate (HR),surgery time,recovery time,extubation time,orientation recovery time,modified Aldrete score ≥9 scores time,rate of recovery from restlessness,tolerance score and recovery from any adverse effects were recorded.ResultsThere were no significant differences between two groups in surgery time,recovery time,extubation time,orientation recovery time,modified Aldrete score ≥ 9 scores time (P >0.05).SBP,DBP,HR at immediately and after extubation with 1,3,5 min of dexmedetomidine group were lower than those of control group(P < 0.05 or < 0.01 ).Tolerance score excellent rate of dexmedetomidine group was higher than that of control group[95.2% (20/21) vs.28.6% (6/21)] (P < 0.05),the rate of recovery from restlessness of dexmedetomidine group was lower than that of control group[0 vs.28.6%(6/21 ) ] (P < 0.05).ConclusionBefore anesthesia induction in patients with venous infusion dexmedetomidine 0.6 p g/kg(finished 10 min infusion),followed by 0.4 p g/(kg·h) continuous infusion can effectively reduce the patients' cardiovascular response to extubation,strengthen the patients' tolerance to endotracheal tube,reduce the patients' agitation and recover consciousness comfortable.
2.Determination of Concentration of Fentanyl in Human Plasma by HPLC With UV Detection
Changfu LIN ; Chunting LIU ; Wenzhi LI ; Enyou LI
China Pharmacy 2001;12(5):286-288
OBJECTIVE: To determine the concentration of fentanyl in human plasma by HPLC with ultraviolet detection METHODS: External standard method was used The eluation of fentanyl was carried out by shim- Pack CLC- ODS( 6 0mm× 150mm, 5μ m) column with 0 015mol/L NaH2PO4 acetonitril- H2O( 30∶ 70, v/v) as the mobile phase, and detection wavelength was 195nm RESULTS: Calibration curve for fentanyl was linear in the range of 2 0~ 100ng/ml( r=0 999) The detection limit was 1 0ng/ml The within- day RSD was ( 6 50± 2 79) % , the between- day RSD Was ( 6 70± 3 04) % The method recovery was ( 91 70± 4 70) % The extraction recovery was ( 97 38± 3 69) % CONCLUSION: This method was quick and accurate for the determination of fentanyl in human plasma and useful for pharmakinetic study of fentanyl
3.Design of digitized anterior approach screw fixation program:Clinical application in the treatment of type Ⅱ odontoid fractures
Xuanhuang CHEN ; Guodong ZHANG ; Changfu WU ; Haibin LIN
Chinese Journal of Tissue Engineering Research 2013;(26):4926-4933
10.3969/j.issn.2095-4344.2013.26.024
4.Analysis of the Causes of Total Fertilization Failure in Vitro Fertilization-Embryo Transfer
Jing DAI ; Zenghui HUANG ; Shuoping ZHANG ; Changfu LU ; Ge LIN
Progress in Modern Biomedicine 2017;17(27):5389-5391,5395
Fertilization is a crucial step for origin of life.During Assisted Reproductive Technologies (ART),total fertilization failure is complex and unpredictable.Total fertilization failure may related to some abnormal cellular mechanistic events,such as:any stage of sperm and cumulus-oocyte-complexes penetration,sperm-zona pellucida binding / penetration,sperm-oocyte membrane binding,oocyte activation,sperm discondensation or pronuclear formation.Most of total fertilization failure could be solved by intracytoplasmic sperm injection.But oocytes of some patient still can't fertilize successfully,even though assisted oocyte activation be used.As for total fertilization failure patients in ART,combining the mature of oocyte,sperm quality and some trail to improve clinical protocol in later cycle may prevent failure to happen again.
5.Preliminary exploration of the influence factors on amplification of single cell duplex-nested PCR
Changgao ZHONG ; Luyun LI ; Changfu LU ; Ge LIN ; Guangxiu LU
Journal of Peking University(Health Sciences) 2004;0(01):-
Objective:To explore the influence factors on amplification of single cell duplex-nested PCR.Methods:The mutational loci region CD41-42 and IVS-Ⅱ654 of ?-globin gene were amplified by duplex-nested PCR with different combination of primers concentration, different Taq DNA polymerases, different neutralization buffers and with or without predenaturation at 98 ℃ before the PCR amplification in single lymphocyte or single blastomere, thus, to investigate the influence of these factors on the amplification efficiency of PCR.Results:TaKaRa EX Taq was the most efficient Taq DNA ploymerase among different Taq DNA ploymerases; primer pair R1+F1 at final concertration of 0.25 ?mol/L and R2+F2 at 0.3 ?mol/L were the most efficient ones in amplification among different combinations of primers concentrations; the amplification efficiency in neutralization buffer-1 (200 mmol/L Tricine) was obviously higher than that of neutralization buffer-2 (900 mmol/L Tris-HCl, pH 8.3/300 mmol/L KCl/200 mmol/L HCl)(P0.05). Conclusion:There were remarkable differences of the amplification efficiency of single cell duplex-nested PCR while using different combination of primers concentrations, different Taq DNA polymerases, different neutralization buffers. However, predenaturation at 98 ℃ before the single cell PCR amplification could not improve the PCR amplification efficiency
6.Influence of patient age and the number of good-quality-embryos transferred on multiple gestation in in vitro fertilization and embryo transfer
Shunji ZHANG ; Fei GONG ; Ge LIN ; Changfu LU ; Hongmei XIAO ; Guangxiu LU
Chinese Journal of Obstetrics and Gynecology 2008;43(8):567-570
Objective To observe the influence of patient′s age, and the number of transferred-good-quality-embryos on multiple gestation rates in in vitro fertilization and embryo transfer(IVF-ET) cycles. Methods In this retrospective study, a total of 4395 patients who transferred fresh embryo between Jan 2004 and Nov 2006 was analyzed. According to the age, the patients were divided into 2 groups: aged < 35 (3442 cycles) or aged ≥135(953 cycles). We regularly transferred 2 -3 embryos. If the patients had only one embryo, one was transferred. And those patients who had only 2 embryos, even if they were more than 35 years old or it would be the second time for them to transfer, were transferred 2 embryos. The influence of female age and the number of good quality embryos transferred on the multiple gestation rates in IVF-ET cycle was analyzed. Results (1)The multiple gestation rate of the groups of 1 good quality embryo,2 good quality embryos, or 3 good quality embryos transferred were 21.08% (35/166), 31.41% (413/1315), and 42. 37% (75/177), respectively in women aged < 35, with a significant difference between them. The pregnancy rates of these groups were 29. 64% (166/560) ,51.63% (1315/2547) ,and 52. 84% (177/335), respectively; there were no significant differences between 2 good quality embryos transferred group and 3 good quality embryos transferred group. (2) The multiple gestation rates of the groups of 1 good quality embryo,2 good quality embryos, or 3 good quality embryos transferred were 19. 51% (8/41) ,20. 65% (19/ 92) ,and 40.66% (74/182), respectively, in women aged ≥ 35; there were no significant differences between 1 good quality embryo transferred group and 2 good quality embryos transferred group. The pregnancy rates of these groups were 19. 07% (41/215), 33.70% (92/273), and 39. 14% (182/465), respectively; there were no significant differences between 2 good quality embryos transferred group and 3 good quality embryos transferred group. (3) The pregnancy rate of the patients aged <35 [48. 17% ( 1658/ 3442) ]was significantly higher than in women aged ≥35[33.05% (315/953) ]. Conclusion The transfer of 2 good quality embryos results in similar pregnancy rates and significantly reduced multiple gestation rates when compared to the transfer of 3 good quality embryos in women regardless of their ages.
7.Odontoid cannulated screw fixation using digital navigation based on three-dimensional printing technique
Xuanhuang CHEN ; Guodong ZHANG ; Changfu WU ; Haibin LIN ; Xu CHEN ; Zhengxi YU ; Yuqing SUN
Chinese Journal of Tissue Engineering Research 2015;(35):5697-5704
BACKGROUND:Odontoid fracture is very common in cervical spine injuries, the special position of odontoid process, which is adjacent to important anatomic structure, makes screw placement difficult, and a slight discrepancy in position and orientation of the inserted screw leads to a decrease in intensity of internal fixation, even invalid internal fixation. Therefore, it is very necessary to develop an individualized treatment protocol by which screws can be precisely and safely placed and which is worthy of clinical popularization. OBJECTIVE:To study the navigation of Mimics software and three dimensional (3D)-printed module in anterior odontoid cannulated screw fixation and to investigate its feasibility and accuracy. METHODS:Sixteen human cadaveric cervical spines were scanned by a continuous thin-slice CT scanner. Original DICOM CT images were three-dimensional y reconstructed using Mimics software. The screw channel and support column were designed for C2 vertebra odontoid cannulated screw fixation for odontoid fracture. Segmentation of bone surface was performed. Navigation modules with screw channel were built using 3D printing technique. Navigation modules were used to aid screw placement. Screw fitting and placement were evaluated using X-ray and CT scan. RESULTS AND CONCLUSION:Total y 16 navigation modules were built and 22 screws were implanted. During and after screw placement, the cortical bone along screw channel and surrounding the vertebral body was not cracked. Postoperative X-ray and CT scans showed that some factors regarding screw placement such as entry point, orientation and depth of placement were consistent with those ideal factors simulated by Mimics software. The navigation modules were closely attached to the corresponding bony structure in front of the vertebral body, with a satisfactory gomphosis. Screw fitting and stability were good during application. These results verify that with the aid of navigation module, anterior odontoid cannulated screw fixation is reliable for treatment of odontoid fracture, which provides insights into the popularization of 3D printing-based digital navigation technique in orthopedic implantation.
8.The influence of peritumoral edema at newly diagnosed glioma on recurrence patterns after total resection
Shuiyuan LIU ; Changfu ZHOU ; Zhixiong LIN ; Songsheng SHI ; Yanlin HUANG ; Hongji CHENG ; Dairong CAO ; Dezhi KANG
Chinese Journal of Nervous and Mental Diseases 2014;(4):223-229
Objective To explore the influence of peritumoral edema (PTE) on the tendency of recurrent location and morphological character after total resection using MRI. Methods MRI data was collected from 43 patients with recur-rent brain glioma after total resection from four clinical centers and then the influence of of PTE on recurrence patterns af-ter total resection was retrospectively analyzed based on the T2 weighted image. Results The PTE had a significant influ-ence on the recurrent patterns of brain gliomas after total resection. When PTE was mild, the shapes of recurrent gliomas tended to be focal (6/8) and the recurrent locations tended to be local (5/8). When PTE was severe, the shapes of the recur- rent gliomas tended to be spread(30/35 and the recurrent locations tended to be distant (25/35), followed by marginal (7/35), In addition, the morphological patterns and locations of recurrent gliomas were significantly different among different PTE types (all P<0.001). When PTE was ring shape, the shapes of recurrent gliomas tended to be focal (7/9) and the recur-rent locations tended to be local (6/9), followed by marginal (2/9) and distant (1/9). When PTE was irregular shape, most of recurrent locations tended to be distant (25/34), followed by marginal (7/34) but rarely local (2/34). Conclusions The de-grees and the types of brain glioma PTE can significantly influence the locations and morphological patterns of recurrent gliomas after total resection.
9.Three-dimensional reconstruction reduction and design of digital plates for proximal tibia fracture
Xuanhuang CHEN ; Xianwei WU ; Haibin LIN ; Changfu WU ; Feng ZHENG ; Qingqing GUO ; Guodong ZHANG
Chinese Journal of Tissue Engineering Research 2015;(26):4235-4241
BACKGROUND:In three-dimensional CT reconstruction model, fracture virtual reduction and internal fixation cannot be achieved, and reasonable operation scheme cannot be formulated. It cannot fuly meet the needs of clinical orthopedics physicians. OBJECTIVE:To explore the methods to perform three-dimensional reconstruction, reduction on proximal tibial fracture and to design digital plate using software. METHODS:Nine specimens of knee joint were built to be A1-3, B1-3 and C1-3 types of proximal tibial fracture according to the AO standard. Al specimens were treated with CT scan. Three-dimensional reconstruction and reduction on nine types of bone fracture models were performed in Mimics. The digital plates and screws were designed in Solidworks. Virtual internal fixation on the reduced three-dimensional models was performed. RESULTS AND CONCLUSION:Al bone fracture models received three-dimensional reconstruction and reduction, and the design for internal fixational plates and screws as wel as virtual internal fixation were accomplished. A3, B3 and C3 types were presented. These results suggest that the digital plates for proximal tibial fracture could be designed in Mimics and Solidworks with a personal computer. Our experience could be used in the real operation.
10.Key techniques of internal fixation for proximal tibial fractures based on digital design and three-dimensional printing
Feng ZHENG ; Zhengxi YU ; Xuanhuang CHEN ; Zugao ZHENG ; Changfu WU ; Xianwei WU ; Haibin LIN ; Guodong ZHANG ; Xu CHEN
Chinese Journal of Tissue Engineering Research 2016;20(26):3837-3842
BACKGROUND:Preliminary experiments have performed three-dimensional (3D) reconstruction of proximal tibial fractures, digital steel plate design, the establishmentof the proximal tibia plate standard parts library and the operation simulation of 3D printing. OBJECTIVE:To explore feasibility and accuracy of standard parts library plates and screws in the proximal tibial fracture internal fixation navigation in digital design combined with 3D printing model on the basis of preliminary studies. METHODS:Dicom format images of continuous thin layer CT scanning were colected in 20 cases of proximal tibial fractures, and uploaded in Mimics software for 3D reconstruction and fracture reduction. Plate and screw selected from standard part library wereusedfor virtual fixation. Navigation module with screw channel was designed. 3D printing skeleton, bone plate, and navigation module were used for skeleton model and internal fixation. Screw and plate were placed by navigation. Navigation module card, nail and board position were observed. Postoperative appearance and CT scanning were utilized to assess outcomes. RESULTS AND CONCLUSION:After CT scanning and reconstructionin 20 skeleton models, in combination with appearance, the position of plate, screw insertion point, the direction, length and diameter of the screw were consistent with that in Mimics software. The navigation module and the corresponding proximal end of the tibia were closely bonded with good fitting degree. In the application, card slots and stability were good, and could perfectly guide plate and screw placement. These reuslts suggest that with the aid of navigation module, standard parts library plate internal fixation for proximal tibia fracture has high accuracy. On the basis of digital design and 3D printing, digital internal fixation technology of standard parts library plate is expected to achieve good implant navigation in the department of orthopedics.