1.Development of Self Training Device for Lung Function Compliance Guided by Meridians.
Ming QI ; Haiying PANG ; Luyang JIA ; Ying FANG ; Aimin WANG ; Hongquan SU ; Xiujuan XIE ; Haiying WANG ; Wenru ZHAO
Chinese Journal of Medical Instrumentation 2021;45(5):503-506
OBJECTIVE:
To develop a self deep breathing training device which can improve lung function compliance and blood oxygen saturation.
METHODS:
The device consists of four parts:flow tube, measuring cylinder, mobile phone holder and meridian guidance audio-visual synthesis training software. The flow tube measures the flow rate of inhaled gas, the metering cylinder measures the total amount of inhaled gas, and the mobile phone rack is equipped with a mobile phone storing the meridian guidance audio-visual synthesis training software.
RESULTS:
The device is reasonable in structure and flexible in operation, which can meet the requirements of self deep inspiration training under the guidance of training module.
CONCLUSIONS
Deep inspiration training under the guidance of guidance training module can form "deep and slow" abdominal breathing, and then improve lung function.
Cell Phone
;
Lung
;
Meridians
;
Software
2.Studies on the microwave leakage of the interphone.
Huan-Ying LI ; Dong-Hui ZHANG ; Jin-Ming LIN ; Wen-Yong LI ; Wei-Jun LI ; Zhong-Yi CHEN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2004;22(6):439-441
OBJECTIVETo assay and study the microwave leakage of 4 types of interphones.
METHODSThe radiation intensities of four types of 199 interphones were determined by the microwave leakage measure instrument of model ML-91 made in China.
RESULTSThe average intensities of microwave leakage at a distance of 5 cm from aerial part and other parts of interphones during launching [(1 316.0 +/- 144.3), (971.0 +/- 131.6) microW/cm(2) respectively] were significantly higher than during waiting [(14.4 +/- 5.3), (13.2 +/- 4.9) microW/cm(2) respectively] (P < 0.01). The average intensities of microwave leakage at a distance of 50 cm from different parts were (357.3 +/- 27.8) microW/cm(2). The daily average intensity of microwave leakage to which the head, chest and abdomen exposed was (945.5 +/- 447.1) microW.h/cm(2) in total, that exceeded the hygienic standard of microwave in China (400 microW.h/cm(2)), during the normal communication by interphones.
CONCLUSIONThe microwave leakage was higher during launching than during waiting, and was the highest at the aerial part of the interphones. The microwave radiation of most interphones was higher than the current national standard. It may lead to potential effects on the owner of interphone, so protection against it should be made.
Cell Phone ; Microwaves ; adverse effects ; Radiation Dosage
3.Smart phones based on the development of the software of exercise intervention.
Wenjun YANG ; Bo YANG ; Baoqiang WANG
Chinese Journal of Medical Instrumentation 2012;36(4):244-247
PURPOSEDeveloping an exercise management software based on a smart phone to intervene wearer's exercise amount.
METHODUsing the Android system of mobile phone which contains acceleration sensor to detect the wearer's exercise amount, at the same time, the sensor send the information to the health management center.
CONSEQUENCEIt can carry out behavior intervention by the health management center's information feedback indication, thus guide the wearer to take exercise scientifically and safely to reach the most effective and appropriate exercising result, which realizes the system function.
CONCLUSIONThe behavior intervention based on Smart phones can apply as a new clinical measure to treat patients.
Cell Phone ; Exercise Therapy ; instrumentation ; Software ; Software Design
4.Development of Muscle Strength Evaluating System Based on Mobile Platform.
Xiulin XU ; Xiaoming YAO ; Xijiao XU ; Xiaohui HU
Journal of Biomedical Engineering 2015;32(4):808-814
The development of muscle strength evaluating system based on Android system was developed in this research. The system consists of a lower unit and an intelligent mobile terminal. The pressure sensor of the lower unit was used to collect muscle strength parameters. And the parameters were sent to the Android device through the wireless Bluetooth serial port. Then the Android device would send the parameters to the doctor monitored platform through the Internet. The system realized analyzing the muscle strength parameters and real-time displaying them. After it ran on the Android mobile phones, it showed an effective result which proved that the system combined with mobile platform could make more convenient for the patients to assess their own muscle strength. It also provided reliable data references for doctors to know the patients' rehabilitation condition and to make the next rehabilitation plan.
Cell Phone
;
Humans
;
Internet
;
Monitoring, Physiologic
;
Muscle Strength
6.Mobile phone based wireless microscopy imaging technology.
Chinese Journal of Medical Instrumentation 2011;35(2):79-82
This article proposes a new device named "Wireless Cellscope" that combining mobile phone and optical microscope together. The established wireless microscope platform consists of mobile phone, network monitor, miniaturized microscope or high resolution microscope etc. A series of conceptual experiments were performed on microscopic observation of ordinary objects and mice tumor tissue slices. It was demonstrated that, the new method could acquire microscopy images via a wireless way, which is spatially independent. With small size and low cost, the device thus developed has rather wide applicability in non-disturbing investigation of cell/tissue culture and long distance observation of dangerous biological sample etc.
Animals
;
Cell Phone
;
Mice
;
Microscopy
;
instrumentation
;
methods
;
Neoplasms
;
Wireless Technology
7.Developing a system to promote good prenatal and postnatal care, and good preschool education based on the cellphone platform.
Zhi-Min LI ; Zhi-Gang PENG ; Li XIE
Chinese Journal of Medical Instrumentation 2008;32(2):126-127
Good prenatal and postnatal care and good preschool education are important approaches to raise the diatheses of population for the chinese nation. This article suggests that the cell phone platform can be used to communicate with each other among the hospitals, the government and the common people, through which the useful informations could be transmitted to the relative persons in time. It's also a new way for propaganda of family planning. This article introduces the structure of the system, the creation of the expert database, and the connection to the telecommunication system.
Cell Phone
;
Family Planning Services
;
methods
;
Software Design
8.Temperature Measurement with Bluetooth under Android Platform.
Shuai WANG ; Hao SHEN ; Changze LUO
Chinese Journal of Medical Instrumentation 2015;39(3):181-196
To realize the real-time transmission of temperature data and display using the platform of intelligent mobile phone and bluetooth. Application of Arduino Uno R3 in temperature data acquisition of digital temperature sensor DS18B20 acquisition, through the HC-05 bluetooth transmits the data to the intelligent smart phone Android system, realizes transmission of temperature data. Using Java language to write applications program under Android development environment, can achieve real-time temperature data display, storage and drawing temperature fluctuations drawn graphics. Temperature sensor is experimentally tested to meet the body temperature measurement precision and accuracy. This paper can provide a reference for other smart phone mobile medical product development.
Body Temperature
;
Cell Phone
;
Humans
;
Programming Languages
;
Software
;
Wireless Technology
9.Investigation on Mobile Phone Based Thermal Imaging System and Its Preliminary Application.
Fufeng LI ; Feng CHEN ; Jing LIU
Chinese Journal of Medical Instrumentation 2015;39(3):173-176
The technical structure of a low-cost thermal imaging system (TIM) lunched on a mobile phone was investigated, which consists of a thermal infrared module and mobile phone and application software. The designing strategies and technical factors toward realizing various TIM array performances are interpreted, including sensor cost and Noise Equivalent Temperature Difference (NETD). In the software algorithm, a mechanism for scene-change detection was implemented to optimize the efficiency of non-uniformity correction (NUC). The performance experiments and analysis indicate that the NETD of the system can be smaller than 150 mK when the integration time is larger than 16 frames. Furthermore, a practical application for human temperature monitoring during physical exercise is proposed and interpreted. The measurement results support the feasibility and facility of the system in the medical application.
Algorithms
;
Body Temperature
;
Cell Phone
;
Humans
;
Infrared Rays
;
Mobile Applications
10.Design of the remote monitoring system of vital sign based on smartphone and mobile internet.
Chuanxue WEN ; Hongjian ZHOU ; Junfei ZHANG
Journal of Biomedical Engineering 2015;32(1):86-92
The present paper presents the design of a remote monitoring system based on smartphone and mobile internet. The system can realize functions such as multi-physiological parameter collection, micromation of collecting equipment, real-time monitoring, remote data transmission, automatic alarm, physiological parameter analyze and Global Position System (GPS) location of patient's position. Besides acting as a receiver and transmission platform, smartphone can also process and analyze the physiological parameters, such as detection of the apnea from electrocardiogram (ECG). The system contains technologies of MCU, Bluetooth transmission, Android and Wed development, wavelet transform, mobile communication as a whole. It propels further developments of the remote mobile medical based on smartphone.
Cell Phone
;
Electrocardiography
;
Geographic Information Systems
;
Humans
;
Internet
;
Monitoring, Ambulatory