1.Posterior Lower Cervical fixation with the AME Haid Universal Bone Plate System.
Journal of Korean Neurosurgical Society 1996;25(5):1017-1022
During posterior cervical stabilization, lateral mass fixation with plate-screw has been found to be a simple and safe application, without the dependence on intact posterior element and immediate rigid fixation. We applied the AME Haid Universal Bone Plate System to six cases of traumatic lower cervical instability with favorable results. Drilling direction was 30 degrees lateral and 15-20 degrees rostral to the vertebral plane, and we have not noticed any complication. Screw loosening, the pitfall of the procedure is described.
Bone Plates*
2.Internal fixation for the spine fusion using long bone plates and screws.
Joo Tae PARK ; Kil Yeong AHN ; Jung Ho YANG
The Journal of the Korean Orthopaedic Association 1991;26(4):1219-1225
No abstract available.
Bone Plates*
;
Spine*
3.The treatment of distal tibia shaft fracture using may anatomical bone plate.
Seung Gyun CHA ; Won Suck LEE ; Jin Hak KIM ; Woo Tae LEE
The Journal of the Korean Orthopaedic Association 1992;27(3):744-752
No abstract available.
Bone Plates*
;
Tibia*
4.A case report of the huge complex odontoma treated with the sagittal splitting of buccal bone plate and iliac bone graft in left mandible angle
Ho Seok KIM ; Jae Chul SONG ; Chin SOo KIM
Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons 1994;15(4):269-274
No abstract available.
Bone Plates
;
Mandible
;
Odontoma
;
Transplants
5.Analysis of Revision Content and Evaluation Attentions on Guidance for Registration of Metallic Bone Plate Internal Fixation System (Revised in 2021).
Jing WU ; Le JIN ; Lihua DONG ; Dan HAN ; Xinli SHI
Chinese Journal of Medical Instrumentation 2023;47(3):312-316
This study briefly introduces the revised content of Guidance for Registration of Metallic Bone Plate Internal Fixation System (Revised in 2021) compared to the original guidance, mainly including the principles of dividing registration unit, main performance indicators of standard specification, physical and mechanical performance research, and clinical evaluation. At the same time, in order to provide some references for the registration of metallic bone plate internal fixation system, this study analyzes the main concerns in the review process of these products based on the accumulation of experience combining with the current review requirements.
Bone Plates
;
Fracture Fixation, Internal
;
Biomechanical Phenomena
8.Autologous grafts of double-strut fibular cortical bone plate to treat the fractures and defects of distal femur: a case report and review of literature.
Xu CHEN ; Jian-Jun LI ; Zhan KONG ; Dong-Xiang YANG ; Xiang-Nan YUAN
Chinese Journal of Traumatology 2011;14(4):241-246
We reported a 23-year-old man who was involved in a high-speed motorcycle accident. He sustained a closed fracture at the right distal femur. The primary fracture happened on February 2008. He underwent open reduction and internal fixation with cloverleaf plate. And one hundred days after the surgery, the proximal screws were pulled-out, but the bone union was not achieved. Treatment consisted of exchanging the cloverleaf plate with a locking compression plate and using an auto-iliac bone graft to fill the nonunion gap. In July 2009, the patient had a sharp pain in the right lower limb. The X-ray revealed that the plate implanted last year was broken, causing a nonunion at the fracture site. Immediately the plate and screws were removed and an intramedullary nail was inserted reversely from the distal femur as well as a 7 cm long bone from the right fibula was extracted and longitudinally split into two pieces to construct cortical bone plates. Then we placed them laterally and medially to fracture site, drilled two holes respectively, and fastened them with suture. We carried on auto-iliac bone grafting with the nonunion bone grafts. The follow-up at 15 months after operation showed that the treatment was successful, X-ray confirmed that there was no rotation and no angular or short deformity. We briefly reviewed the literature regarding such an unusual presentation and discussed in details the possible etiology and the advantages of autologous double-strut fibular grafts to cope with such an intractable situation.
Bone Plates
;
Femur
;
Fibula
;
Fracture Fixation, Internal
;
Fractures, Bone
;
Humans
9.Effect of screw number and length on internal fixation of mandibular fractures.
Sun Youl RYU ; Yeong Joon PARK
Journal of the Korean Association of Oral and Maxillofacial Surgeons 1997;23(1):63-68
This study was performed to evaluate the effect that screw number and length have on the ability of two types of plate to resist vertical masticatory force. Five trials were done with two, four, or six screws, using screws 4 mm, or 12 mm in lenght and mini bone plates or mini compression plates. The fractured ribs were subjected to increasing weights until failure. With the mini bone plate, increasing the number of screws increased the weight resisted than screw length. For the mini compression plate, increasing screw length and the number of screws increased weight resisted.
Bite Force
;
Bone Plates
;
Mandibular Fractures*
;
Ribs
;
Weights and Measures
10.Cone-beam computed tomography digital for measuring the inclination angle to the long axis of healthy maxillary anterior teeth and morphologically characterizing their labial bone plates.
Yang HAN ; Xiao-Guang LI ; Jie ZHU ; Jing-Wen LI ; Su-Ning HU ; Cong LI ; Jing ZHAO ; Yu-Hong LIANG
West China Journal of Stomatology 2019;37(4):412-416
OBJECTIVE:
We aim to determine the thickness of the labial plate, the distance between the cement-enamel junction (CEJ) and alveolar crest, and the inclination angle of the long axis of healthy maxillary anterior teeth by using cone- beam computed tomography (CBCT).
METHODS:
A total of 345 CBCT volumes obtained by Newtom VGI® CBCT were analyzed by using the NNT software. The digital measurements of the labial bone plate thickness at level 4 mm below the CEJ, the midpoint of tooth root and the radiological tooth apex, the distance between the CEJ and alveolar crest, and the angle between the long axis of the teeth and the long axis of alveolar process were obtained from the mid-sagittal planes of maxillary incisors and canines. Plate thickness 4 mm below the CEJ was measured, and values below ≥1 mm were recorded.
RESULTS:
In the central incisor, 1) the angle between the long axis of the teeth and alveolar bone was 15.2°±6.2°, the distance between the CEJ and alveolar crest was (1.5±1.0) mm, labial bone plate thick-ness at 4 mm below the CEJ was (0.8±0.4) mm, the midpoint of tooth root was (0.6±0.4) mm, and the radiological tooth apex was (1.3±0.7) mm; in the lateral incisor, 16.2°±8.8°, (1.6±1.0) mm, (0.7±0.5) mm, (0.4±0.6) mm, and (1.1±0.7) mm, respectively; and in the canine, 19.0°±6.2°, (1.8±1.0) mm, (0.9±0.6) mm, (0.4±0.6) mm, and (1.2±0.7) mm, respectively. 2) The frequencies of plate thickness ≥1 mm were 28.3%, 25.8%, and 42.7% in the central incisor, lateral incisor, and canine, respectively. 3) The distance between the CEJ and alveolar crest was positively correlated with age. The correlation coefficients was 0.42 (P<0.01) in the central incisor, 0.50 (P<0.01) in the lateral incisor, and 0.62 (P<0.01) in the canine.
CONCLUSIONS
The thickness of labial bone plate is thin, the distance from CEJ to alveolar crest increases with age, and the long axis of the teeth is more inclined than the long axis of alveolar process. Knowledge of these special morphological characteristics can improve the safety and result for many dental procedures.
Alveolar Process
;
Bone Plates
;
Cone-Beam Computed Tomography
;
Incisor
;
Maxilla