1.Clinical application of lower cross-lip flap in treatment of upper lip defect
Jingjian WEI ; Jingqian XIAO ; Zhengyu LIU ; Bocheng LEI ; Xukai WANG
Chinese Journal of Medical Aesthetics and Cosmetology 2013;19(5):334-336
Objective To evaluate the clinical effect of the upper lip defect with lower cross-lip flap (Abbe-Estlander flap).Methods A total of 68 cases of upper lip defect underwent the reconstruction with cross-lip flaps.We applied Abbe flap in upper lip defect in the center,and Estlander flap in lateral upper lip defect.This method was a two-stage procedure:the first stage was to rotate flap 180 degrees into the upper lip defect and to suture with the created defect of the upper lip,with careful maintenance of blood supply from the pedicle; the second was to undertake the division of bridged pedicle and paid more attention to creation of the vermilion border.Results The flaps survived in all cases.Evaluation from 3 to 12 months after the operation showed that the shape of lips were obviously repaired with excellent aesthetic and functional results.Conclusions Abbe-Estlander flap could reconstruct anatomical features and function of the lip precisely.It seems that within certain limits (probably between one-third and one-half of total upper lip length),this flap appears to be the preferred method for upper lip reconstruction.
2.Simultaneous Determination of the Content of Berberine Hydrochloride,Baicalin and Osthole in Jinchan Zhiyang Capsules by HPLC
Chuanjun HUANG ; Yong MEI ; Li YANG ; Lei LUO ; Bocheng ZENG ; Tao LONG ; Kaichao YUAN ; Zhiwen QIAO ; Xiaoxue CHEN
China Pharmacy 2018;29(12):1621-1624
OBJECTIVE:To establish the method for simultaneous determination of the content of berberine hydrochloride, baicalin and osthole in Jinchan zhiyang capsules. METHODS:HPLC method was adopted. The determination was performed in Hypersil BDS C18 column with mobile phase consisted of methanol-acetonitrile-0.1%phosphoric acid-three triethylamine(50∶30∶19∶1, V/V/V/V) at the flow rate of 1.0 mL/min. The detection wavelengths were set at 265 nm (berberine hydrochloride),280 nm (baicalin)and 322 nm(osthole). The column temperature was set at 30 ℃,and sample size was 10 μL. RESULTS:The linear range of berberine hydrochloride,baicalin and osthole were 80-800 ng(r=0.999 8),60-600 ng(r=0.999 9),60-600 ng(r=0.999 6),respectively. RSDs of precision,stability and reproducibility tests were all lower than 2.0%. The limits of quantitation were 80,60,60 ng,respectively,and the limits of detection were 24,20,20 ng,respectively. The recovery rates were 97.4%-98.3%(RSD=0.33%,n=6),98.4%-99.6%(RSD=0.42%,n=6)and 96.9%-99.0%(RSD=0.92%,n=6),respectively. RSDs of durability tests were all lower than 1.2%. CONCLUSIONS:The method is simple, accurate, precise, stable, reproducible and durable. It can be used for simultaneous determination of berberine hydrochloride,baicalin and osthole in Jinchan zhiyang capsules.
3.Simultaneous Determination of Berberine Hydrochloride and Baicalin in Jianpi Zhixiening Granules by HPLC-switching Walvelength Method
Chuanjun HUANG ; Li YANG ; Yong MEI ; Lei LUO ; Shanshan LYU ; Bocheng ZENG ; Tao LONG ; Feng WANG ; Juan ZUO ; Kaichao YUAN ; Pan TANG ; Feng ZHU ; Bo CHEN ; Zhiwen QIAO
China Pharmacy 2018;29(10):1324-1327
OBJECTIVE:To establish the method for simultaneous determination of berberine hydrochloride and baicalin in Jianpi zhixiening granules. METHODS:HPLC switching walvelength method was adopted. The determination was performed on Hypersil BDS C18 column with mobile phase consisted of methanol-0.45% phosphoric acid solution-triethylamine(50:49:1,V/V/V) at the flow rate of 1.0 mL/min. The detection wavelength was set at 265 nm(berberine hydrochloride)and 280 nm(baicalin). The column temperature was set at 30 ℃,and sample size was 10 μL. RESULTS:The linear range of berberine hydrochloride and baicalin were 60.3-312.8 ng(r=0.9997)and 81.5-368.9 ng(r=0.9999). The limits of quantitation were 0.6668,0.7740 ng,andthe limits of detection were 0.2226,0.2580 ng,respectively. RSDs of intermediate precision,stability and repeatability tests were all lower than 1.0%. The recoveries were 96.48%-99.30%(RSD=1.06%,n=6) and 95.20%-99.39%(RSD=1.66%,n=6), respectively. RSDs of durability test were all lower than 2.0%. CONCLUSIONS:The method is simple, precise, stable, reproducible,accurate and durable. It can be used for simultaneous determination of berberine hydrochloride and baicalin in Jianpi zhixiening granules.