1. Differences in relative parameters of acetabulum in hip arthroplasty between CT horizontal plane and CT true pelvic plane
Chinese Journal of Tissue Engineering Research 2020;24(9):1405-1409
BACKGROUND: The accuracy of acetabular prosthesis placement during total hip arthroplasty has a direct effect on postoperative hip function, stability and service life. Unreasonable placement of the cup may lead to adverse events, so CT imaging should be emphasized. OBJECTIVE: To analyze the differences of acetabular parameters in hip arthroplasty between the horizontal and true pelvic planes on CT images, and to determine the possible impact on surgery outcomes. METHODS: Seventy-two cases of pelvic soft tissue disease were selected. All patients signed the informed consents, and the study was approved by the hospital ethics committee. The anteversion angle, acetabular angle, acetabular depth, acetabular width, femoral head midpoint-acetabular margin angle, abduction angle between the true pelvic plane and the horizontal plane were measured by CT positioning film and its scanning image. CT software was selected to reconstruct the three-dimensional image, and then scanned vertically with the true pelvic plane. The above parameters were measured in the same way. The differences of parameters between left and right acetabulum and two planes were compared by paired t test. Spearman correlation analysis was used to analyze the correlation between the angles between the two reference planes and the difference between the measured parameters. RESULTS AND CONCLUSION: (1) There was no significant difference in the values of the left and right acetabular parameters between the horizontal plane and the true pelvic plane (P > 0.05). (2) The pelvic tilt angle was positively correlated with the femoral head midpoint-acetabular margin angle and the acetabular anteversion angle between the two reference surfaces, and negatively correlated with the acetabular angle and acetabular depth. (3) Our results suggest that during the CT scan of the supine position, the pelvis is accompanied by a rotation condition. The parameters of the true pelvis plane as a reference are inaccurate with the directly measured acetabular parameters. Therefore, attention should be paid to the preparation of the surgical plan before surgery.
2.A novel integrated patient specific instrumentation system and its application for total knee arthroplasty
Bing QIU ; Mingjiao ZHANG ; Bensen TANG ; Fei LIU ; Weimin ZHU ; Dong ZHEN ; Fang LIU ; Biyong DENG
Chinese Journal of Orthopaedics 2016;(3):143-150
Objective To study the accuracy of preoperative planning and postoperative satisfaction of prosthesis posi?tion by applying the personal surgical cutting guide (PSCG) to total knee arthroscopy (TKA) based on 3D printing technique. Meth?ods In this randomized study, 20 patients were selected from August 2014 to October 2015, who were randomly divided into two groups. In PSCG group, 4 males and 6 females were enrolled, with a mean age of 70.9±6.69 (from 59 to 78) years. In con?ventional instrumentation group, 2 males and 8 females were enrolled, with a mean age of 69.9 ± 6.35 (from 58 to 77) years. The conventional instrumentation group was treated with conventional TKA, while the PSCG group was treated with personal surgical cutting guides. Then the knee valgus angle of patients, the angle between prosthesis components on the coronal and the sagittal plane of two groups were evaluated. Subsequently the correlation of the actual osteotomy amount, the valgus angle, caster angle, external rotation angle between intra? and preoperative planning were compared in the PSCG group. Results Compared with the ideal value of each angle, the mean deviation of the hip?knee?ankle angle 0.77°±0.51°, frontal femoral compo?nent angle 0.37° ± 0.53° and frontal tibial component angle 0.11° ± 0.24° showed statistically significant difference between two groups (P<0.05). The mean deviation of the lateral femoral component angle and the lateral tibial component angle (respectively 8.26°±0.85°, 0.71°±0.77°) were smaller than that of the conventional instrumentation group, while the differences all had no statis?tically significant difference (P>0.05). The actual osteotomy amount, the valgus angle, caster angle, external rotation angle corre?lated well between intra?and preoperative planning (t=-2.547, 3.864, 0.537,-0.040,-1.290, P>0.05). Conclusion TKA assist?ed by PSCG can make lower extremity alignment and accuracy of prosthesis implantation more accurate compared with convention?al TKA, especially in hip?knee?ankle angle, frontal femoral component angle and frontal tibial component angle.
3.Total knee arthroplasty based on the assistance of three-dimensional-printing personalized surgical navigation template
Bing QIU ; Mingjiao ZHANG ; Bensen TANG ; Biyong DENG ; Dichen LI ; Fei LIU
Chinese Journal of Tissue Engineering Research 2015;(48):7731-7735
BACKGROUND:With significantly individual differences in the anatomy of the knee joint, traditional total knee replacement is difficult to accurately predict the position of locating limb alignment, size of the prosthesis and osteotomy amount of patients during operation. OBJECTIVE:To investigate the clinical effect of total knee replacement based on the assistance of medical image reconstruction, computer-aided design technology and 3D-printing personalized surgical navigation template. METHODS:Medical image data of patients were col ected using CT or magnetic resonance scanning equipment. The three-dimensional reconstruction of the bone was conducted by two-dimensional medical image processing technology. The navigation template was designed by computer-aided design technology. The personalized surgical navigation templates were produced by 3D printing technology, and the clinical total knee replacement was conducted. The postoperative results were evaluated using imageology. RESULTS AND CONCLUSION:Arigin 3D Pro (Arigin Medical Co., Ltd.) can accurately reconstruct a three-dimensional model of the lower limb bones. The three-dimensional design software Arigin Surgical Templating by their independent research and development can precisely pinpoint related lower limb axis, including limb alignment, rotation axis of the femur and osteotomy reference point. The personalized navigation template we researched and produced for knee surgery fitted tightly with femoral condyle and tibial plateau bone anatomy during operation, without significant movement. The deviation of patients’ limb alignment was less than 3° after total knee replacement.
4.Effect of Comprehensive Psychotherapy on Psychology of Cancer Patients
Biyong REN ; Xuefen LIU ; Jun ZHANG ; Li ZHANG ; Chao DENG ; Xiaoping HUANG ; Huawen LIU ; Wenhua RAN ; Gang LI
China Pharmacy 2005;0(22):-
OBJECTIVE:To study the effect of comprehensive psychotherapy on psychology of cancer patients received chemotherapy or radiotherapy. METHODS:77 cancer patients received chemotherapy or radiotherapy were divided into two groups. Both groups received routine chemotherapy or radiotherapy. Intervention group(n=40)were additionally given comprehensive psychotherapy,i.e. cognitive therapy,psychological persuasion and relaxation training. Self-rating anxiety scale(SAS)and self-rating depression scale(SDS)were applied to evaluate all patients one week before intervention and one month after comprehensive psychotherapy. RESULTS:SAS and SDS scores of intervention group were significantly lower than that of control group after treatment(P0.05). CONCLUSION:Comprehensive psychotherapy can improve the mental state of patients with can-cer.
5.Detection of Plasmodium falciparum by using magnetic nanoparticles separa-tion-based quantitative real-time PCR assay
Fei WANG ; Yin TIAN ; Jing YANG ; Fujun SUN ; Ning SUN ; Biyong LIU ; Rui TIAN ; Guanglu GE ; Mingqiang ZOU ; Congliang DENG ; Yi LIU
Chinese Journal of Schistosomiasis Control 2014;(5):522-525,530
Objective To establish a magnetic nanoparticles separation-based quantitative real-time PCR(RT-PCR)assay for fast and accurate detection of Plasmodium falciparum and providing a technical support for improving the control and preven-tion of imported malaria. Methods According to the conserved sequences of the P. falciparum genome 18SrRNA,the species-specific primers and probe were designed and synthetized. The RT-PCR was established by constructing the plasmid standard , fitting the standard curve and using magnetic nanoparticles separation. The sensitivity and specificity of the assay were evaluat-ed. Results The relationship between the threshold cycle(Ct)and logarithm of initial templates copies was linear over a range of 2.5×101 to 2.5×108 copies/μl(R2=0.999). Among 13 subjects of entry frontier,a P. falciparum carrier with low load was de-tected by using the assay and none was detected with the conventional examinations(microscopic examinations and rapid tests). Conclusion This assay shows a high sensitivity in detection of P. falciparum,with rapid and accurate characteristics,and is especially useful in diagnosis of P. falciparum infectors with low parasitaemia at entry-exit frontier ports.