1.Nosocomial Infection in Schizophrenics with Tuberculosis:A Clinical Analysis
Zhixing JIN ; Wenzhong CHEN ; Bingrong YUAN ; Ping XU ; Jianxi SHI
Chinese Journal of Nosocomiology 2006;0(08):-
OBJECTIVE To investigate the clinical features and causes of nosocomial infection in schizophrenics with tuberculosis so as to take effective measures for better prevention and treatment.METHODS A retrospective investigation was used to analyze the clinical features and causes of nosocomial infection in 207 schizophrenics with tuberculosis.RESULTS The rate of nosocomial infection in schizophrenics with tuberculosis was 39.13%.The main infection way was via respiratory tract,followed by skin,soft tissue and gastrointestinal tract.The period and degrees of tuberculosis,the history of smoking,psychiatric symptoms and the complications were the causes of nosocomial infection.CONCLUSIONS Controlling psychiatric symptoms actively,preventing and treating somatic complications,using antibiotics rationally and less or no smoking are the effective measures to avoid nosocomial infection in schizophrenics with tuberculosis.
2.Development of the robotic digestive endoscope system and an experimental study on mechanistic model and living animals (with video)
Bingrong LIU ; Yili FU ; Kaipeng LIU ; Deliang LI ; Bo PAN ; Dan LIU ; Hao QIU ; Xiaocan JIA ; Jianping CHEN ; Jiyu ZHANG ; Mei WANG ; Fengdong LI ; Xiaopeng ZHANG ; Zongling KAN ; Jinghao LI ; Yuan GAO ; Min SU ; Quanqin XIE ; Jun YANG ; Yu LIU ; Lixia ZHAO
Chinese Journal of Digestive Endoscopy 2024;41(1):35-42
Objective:To develop a robotic digestive endoscope system (RDES) and to evaluate its feasibility, safety and control performance by experiments.Methods:The RDES was designed based on the master-slave control system, which consisted of 3 parts: the integrated endoscope, including a knob and button robotic control system integrated with a gastroscope; the robotic mechanical arm system, including the base and arm, as well as the endoscopic advance-retreat control device (force-feedback function was designed) and the endoscopic axial rotation control device; the control console, including a master manipulator and an image monitor. The operator sit far away from the endoscope and controlled the master manipulator to bend the end of the endoscope and to control advance, retract and rotation of the endoscope. The air supply, water supply, suction, figure fixing and motion scaling switching was realized by pressing buttons on the master manipulator. In the endoscopy experiments performed on live pigs, 5 physicians each were in the beginner and advanced groups. Each operator operated RDES and traditional endoscope (2 weeks interval) to perform porcine gastroscopy 6 times, comparing the examination time. In the experiment of endoscopic circle drawing on the inner wall of the simulated stomach model, each operator in the two groups operated RDES 1∶1 motion scaling, 5∶1 motion scaling and ordinary endoscope to complete endoscopic circle drawing 6 times, comparing the completion time, accuracy (i.e. trajectory deviation) and workload.Results:RDES was operated normally with good force feedback function. All porcine in vivo gastroscopies were successful, without mucosal injury, bleeding or perforation. In beginner and advanced groups, the examination time of both RDES and ordinary endoscopy tended to decrease as the number of operations increased, but the decrease in time was greater for operating RDES than for operating ordinary endoscope (beginner group P=0.033; advanced group P=0.023). In the beginner group, the operators operating RDES with 1∶1 motion scaling or 5∶1 motion scaling to complete endoscopic circle drawing had shorter completion time [1.68 (1.40, 2.17) min, 1.73 (1.47, 2.37) min VS 4.13 (2.27, 5.16) min, H=32.506, P<0.001], better trajectory deviation (0.50±0.11 mm, 0.46±0.11 mm VS 0.82±0.26 mm, F=38.999, P<0.001], and less workload [42.00 (30.00, 50.33) points, 43.33 (35.33, 54.00) points VS 52.67 (48.67, 63.33) points, H=20.056, P<0.001] than operating ordinary endoscope. In the advanced group, the operators operating RDES with 1∶1 or 5∶1 motion scaling to complete endoscopic circle drawing had longer completion time than operating ordinary endoscope [1.72 (1.37, 2.53) min, 1.57 (1.25, 2.58) min VS 1.15 (0.86, 1.58) min, H=13.233, P=0.001], but trajectory deviation [0.47 (0.13, 0.57) mm, 0.44 (0.39, 0.58) mm VS 0.52 (0.42, 0.59) mm, H=3.202, P=0.202] and workload (44.62±21.77 points, 41.24±12.57 points VS 44.71±17.92 points, F=0.369, P=0.693) were not different from those of the ordinary endoscope. Conclusion:The RDES enables remote control, greatly reducing the endoscopists' workload. Additionally, it gives full play to the cooperative motion function of the large and small endoscopic knobs, making the control more flexible. Finally, it increases motion scaling switching function to make the control of endoscope more flexible and more accurate. It is also easy for beginners to learn and master, and can shorten the training period. So it can provide the possibility of remote endoscopic control and fully automated robotic endoscope.
3.A national questionnaire survey on endoscopic treatment for gastroesophageal varices in portal hypertension in China
Xing WANG ; Bing HU ; Yiling LI ; Zhijie FENG ; Yanjing GAO ; Zhining FAN ; Feng JI ; Bingrong LIU ; Jinhai WANG ; Wenhui ZHANG ; Tong DANG ; Hong XU ; Derun KONG ; Lili YUAN ; Liangbi XU ; Shengjuan HU ; Liangzhi WEN ; Ping YAO ; Yunxiao LIANG ; Xiaodong ZHOU ; Huiling XIANG ; Xiaowei LIU ; Xiaoquan HUANG ; Yinglei MIAO ; Xiaoliang ZHU ; De'an TIAN ; Feihu BAI ; Jitao SONG ; Ligang CHEN ; Yingcai MA ; Yifei HUANG ; Bin WU ; Xiaolong QI
Chinese Journal of Digestive Endoscopy 2024;41(1):43-51
Objective:To investigate the current status of endoscopic treatment for gastroesophageal varices in portal hypertension in China, and to provide supporting data and reference for the development of endoscopic treatment.Methods:In this study, initiated by the Liver Health Consortium in China (CHESS), a questionnaire was designed and distributed online to investigate the basic condition of endoscopic treatment for gastroesophageal varices in portal hypertension in 2022 in China. Questions included annual number and indication of endoscopic procedures, adherence to guideline for preventing esophagogastric variceal bleeding (EGVB), management and timing of emergent EGVB, management of gastric and isolated varices, and improvement of endoscopic treatment. Proportions of hospitals concerning therapeutic choices to all participant hospitals were calculated. Guideline adherence between secondary and tertiary hospitals were compared by using Chi-square test.Results:A total of 836 hospitals from 31 provinces (anotomous regions and municipalities) participated in the survey. According to the survey, the control of acute EGVB (49.3%, 412/836) and the prevention of recurrent bleeding (38.3%, 320/836) were major indications of endoscopic treatment. For primary [non-selective β-blocker (NSBB) or endoscopic therapies] and secondary prophylaxis (NSBB and endoscopic therapies) of EGVB, adherence to domestic guideline was 72.5% (606/836) and 39.2% (328/836), respectively. There were significant differences in the adherence between secondary and tertiary hospitals in primary prophylaxis of EGVB [71.0% (495/697) VS 79.9% (111/139), χ2=4.11, P=0.033] and secondary prophylaxis of EGVB [41.6% (290/697) VS 27.3% (38/139), χ2=9.31, P=0.002]. A total of 78.2% (654/836) hospitals preferred endoscopic therapies treating acute EGVB, and endoscopic therapy was more likely to be the first choice for treating acute EGVB in tertiary hospitals (82.6%, 576/697) than secondary hospitals [56.1% (78/139), χ2=46.33, P<0.001]. The optimal timing was usually within 12 hours (48.5%, 317/654) and 12-24 hours (36.9%, 241/654) after the bleeding. Regarding the management of gastroesophageal varices type 2 and isolated gastric varices type 1, most hospitals used cyanoacrylate injection in combination with sclerotherapy [48.2% (403/836) and 29.9% (250/836), respectively], but substantial proportions of hospitals preferred clip-assisted therapies [12.4% (104/836) and 26.4% (221/836), respectively]. Improving the skills of endoscopic doctors (84.2%, 704/836), and enhancing the precision of pre-procedure evaluation and quality of multidisciplinary team (78.9%, 660/836) were considered urgent needs in the development of endoscopic treatment. Conclusion:A variety of endoscopic treatments for gastroesophageal varices in portal hypertension are implemented nationwide. Participant hospitals are active to perform emergent endoscopy for acute EGVB, but are inadequate in following recommendations regarding primary and secondary prophylaxis of EGVB. Moreover, the selection of endoscopic procedures for gastric varices differs greatly among hospitals.
4.Procalcitonin could be a reliable marker in differential diagnosis of post-implantation syndrome and infection after percutaneous endovascular aortic repair.
Ling XUE ; Songyuan LUO ; Jianfang LUO ; Zhen LIU ; Mengnan GU ; Huiyuan KANG ; Fan YANG ; Bingrong NIE ; Yuan LIU ; Wenhui HUANG ; Nianjin XIE ; Pengcheng HE ; Haojian DONG ; Zhonghan NI ; Ruixin FAN ; Jiyan CHEN
Chinese Medical Journal 2014;127(14):2578-2582
BACKGROUNDThoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease. However, the clinical manifestations of systemic inflammatory response after TEVAR as post-implantation syndrome (PIS) resemble the perioperative infection. This study aimed to evaluate changes and diagnostic value of procalcitonin (PCT) and other traditional inflammatory markers for infections after TEVAR.
METHODSWe conducted a prospective clinical study that enrolled 162 consecutive aortic dissection cases, who underwent TEVAR in our institution between July 2011 and November 2012. The PCT, C-response protein (CRP), erythrocyte sedimentation rate (ESR) and blood routine examination were monitored before the operation and on days 1, 2, 3 and 5 after the operation. The diagnosis of infection was confirmed by the infection control committee with reference to Hospital Acquired Infection Diagnostic Criteria Assessment, released by the Ministry of Health of the People's Republic of China.
RESULTSPost endovascular repair of thoracic aorta, PCT changes significantly at different time points (χ(2) = 13.225, P = 0.021), without significant difference between the PIS group and the control group (0.24 ± 0.04 vs.0.26 ± 0.10, P = 0.804). PCT values were significantly higher in the first day after TEVAR than the preoperative levels (0.18 ± 0.03 vs. 0.11 ± 0.02, P < 0.001). Compared with PIS patients, the level of PCT, CRP, White blood cell (WBC) and neutrophil (NEU) in the infection patients elevated significantly (relatively χ(2) = 6.062, P = 0.048; χ(2) = 6.081, P = 0.048; χ(2) = 11.030, P = 0.004; χ(2) = 14.632, P = 0.001). According to the ROC analysis, the PCT levels in the first day after TEVAR (AUC = 0.785, P = 0.012) had better predictive values of infection than WBC, NEU CRP and ESR (AUC = 0.720, P = 0.040; AUC = 0.715, P = 0.045; AUC = 0.663, P = 0.274; AUC = 0.502, P = 0.991). The best predictive index was the changes of PCT between preoperative and postoperative (PCT), which possess AUC as 0.803 (P = 0.014). And PCT = 0.055 could be considered as an infection diagnosis cutoff value with a sensitivity of 83.3% and specificity 69.0%.
CONCLUSIONSPCT provides better diagnostic value of infection compared with other inflammatory markers. The potential applications of PCT in differential diagnosis of PIS and infection after percutaneous TEVAR deserve further studies.
Adult ; Aged ; Blood Sedimentation ; C-Reactive Protein ; metabolism ; Calcitonin ; metabolism ; Calcitonin Gene-Related Peptide ; Diagnosis, Differential ; Female ; Humans ; Male ; Middle Aged ; Prospective Studies ; Protein Precursors ; metabolism ; Vascular Surgical Procedures