1.Diagnosis of Breast Cancer in Early Stage and Application of Mammography
Chinese Medical Equipment Journal 2003;0(10):-
Objective To explore the effect of mammography in the diagnosis of early breast cancer. Methods 33 early stage breast cancer patients were confirmed by surgical operation and pathology and diagnosed by mammography at the same time to analyse the relationship between the signs of X-ray and early stage breast cancer. Results 16 of 33 patients X-ary signs included mass with spiculate border and lobulate margins,followed by 8 cases of calcification like needle point,5 cases duct enlarge and 14 cases indirect signs. Conclusion Clinical touch examination cambined with mammography is very important to diagnose early breast cancer,especially mammography is necessary to the cases which were found nothing by clinical touching.
2.Structural Classification and Functional Characterization ofShort-Chain Scorpion Toxic Peptides
Progress in Biochemistry and Biophysics 2001;28(1):44-48
Recent research has revealed that scorpion venom contains short-chain peptides with the specificity on K+or C1-channels, in addition to the knowledge of many kinds of long-chain peptides with the specificity on Na+ channels. According to the similarity of molecular structure and/or function, they have been classified into several groups. These short-chain scorpion peptides are playing more and more important role in studying the structure and function of K+ or C1- channels. The advance of structure and function of short-chain scorpion peptides in recent years was briefly introduced.
3.Optimization and application of temporal bone scanning parameters
Chinese Medical Equipment Journal 1989;0(01):-
Objective To optimize the temporal bone scanning parameters, upgrade the picture quality, shorten the scanner time, and decrease the radiographic exposure during the scanning. Methods The scanning was performed on 20 volunteers using 16 spiral CT in the same position and range with optimizer parameters and general parameters respectively, and then the volume data were collected. Results Through comparision and analysis of the images of the 20 volunteers, 17 of them using the optimizer parameters were better than those using general ones, 2 of them showed no obvious difference, and 1 was not as good as the general one. Conclusions Through the experiment and the statistics of 1000 cases using optimizer parameters, the picture quality using optimizer parameters is better, the scanner time is 1/7 of the general scanning, and the radiographic exposure is decreased. Optimizer parameters are better than the general ones and worth popularizing.
4.Sonographic features of follicular thyroid carcinoma th
Chinese Journal of Medical Ultrasound (Electronic Edition) 2013;(6):484-488
Objective To determine sonographic features of thyroid follicular carcinoma ( FC) in comparison with thyroid follicular adenoma ( FA ).Methods This retrospective study included 36 pathologically proven FCs (5 widely invasive FCs and 31 minimally invasive FCs)and 52 FAs in 88 patients who underwent thyroid surgery .We analyzed clinical features of each patient ,including patient gender,age, and sonographic features of each tumor , including maximum diameter, peripheral halo, echogenicity, echotexture,calcifications and nodule number .These clinical and sonographic findings were compared by using t test ( age and diameter ) or the χ2 test (sex ratio,halo,echogenicity,echotexture,calcifications and nodularity)between FAs and FCs.Results For sonographic features,predominantly solid content(100.0%, 36/36),hypoechoic echogenicity (69.4%,25/36),inhomogeneous echotexture (83.9%,26/32),presence of calcifications(55.6%, 20/36) and without or with irregular halo (69.4%,25/36) were more commonly found in FCs.In comparison,FAs were more likely to present with mixed or predominantly cystic content (61.5%,32/52),isoechoic echogenicity (63.5%,33/52),homogeneous echotexture (80.8%,42/52), absence of calcifications (7.7%,4/52) and thin halo (86.5%,45/52) ( χ2 =34.813,28.596,35.256, 25.052,28.811,all P<0.01).The maximum diameter and mean age did not show statistically significant difference between FCs and FAs (t=0.222,-1.228,P=0.825,0.223).The proportions of tumor larger than 40 mm(22.2%,8/36 vs 17.3%,9/52),solitary nodule(31.3%,12/24 vs 21.2%,11/41),male sex (25.0%,9/27 vs 23.1%,12/40)and patient older than 45 years(66.7%,24/36 vs 71.2%,37/52)did not show statistically significant difference between FCs and FAs ( χ2 =0.330,1.635,0.043,0.201,all P>0.05).Conclusion Sonographic features,including predominantly solid content ,hypoechoic echogenicity, inhomogeneous echotexture ,presence of calcifications and without or with irregular halo were more commonly seen in FCs.
5. Sex-dependent differences in DNA copy number alterations in hepatocellular carcinoma
Academic Journal of Second Military Medical University 2012;33(1):5-9
Objective To identify the sex-related DNA copy number alterations (CNA) in hepatocellular carcinoma (HCC). Methods High-resolution array comparative genomic hybridization Carray- CGH) was used to examine 17 female and 46 male HCCs. Two-tailed Fisher's exact test or χ2 test was used to compare the differences in CNA between females and males. Results The overall frequencies and patterns of CNA in female and male cases were similar. However, female HCC tumors presented more copy number gains compared to male on lq21. 3-q22(76. 5% vs 37. 0%, P = 0. 009), llqll(35. 3% vs 0. 0%, P = 0. 000 2) and 19ql3. 31-ql3. 32(23. 5% vs 0. 0%, P = 0. 004), and more loss on 16pll. 2(35. 3% vs 6. 5%, P = 0. 009). Relative to females, male cases had more copy number loss on llqll(63. 0% vs 17. 6%, P = 0. 002). Further analyses showed that llqll gain was correlated with 19ql3. 31-ql3. 32 gain(P = 0. 042) and 16pll. 2 loss(P = 0. 033), while lq21. 3-q22 gain was correlated with 19ql3. 31-ql3. 32 gain(P = 0. 046). Conclusion Our findings suggest that CNA may play an important role in sex-related difference in HCC development.
6.Discussion on curriculum provision of biomedical software application for medical postgraduates
Xin ZHOU ; Wenjie JI ; Bing HE
Chinese Journal of Medical Education Research 2013;(5):452-454
Proper use of biochemical software is helpful for medial post-graduate students to establish scientific thinking behavior during research and to improve their creative capability.Exploration on curriculum of biomedical software application was made based on course objective and content,modern teaching methods and practical assessment methods.Results showed that this training course can enhance the students' understanding and practical skill of related software,which is fundamental for further research work.
7.HPLC Fingerprints of Lonicera similis from Sichuan and Chongqing
Chunhong LI ; Ji TIAN ; Bing HE
China Pharmacy 2005;0(21):-
OBJECTIVE: To establish the fingerprints of Lonicera similis from Sichuan and Chongqing.METHODS: Chlorogenic acid was taken as the reference substance.The separation was carried out on Dikma Kromasil C18(250 mm?4.6 mm,10 ?m) column with methanol-0.1% phosphoric acid solution as mobile phase(in gradient elution) under a detection wavelength of 326 nm.RESULTS: A total of 11 common peaks appeared in the 10 batches of L.similis samples,and the parameters of the common peaks were up to the standard of the specification for fingerprints of Chinese medicine injections.CONCLUSION: The established HPLC fingerprints can be used as a reference for the quality evaluation and variety discrimination of L.similis.
8.Clinical Observation on Yin-nourishing and Qi-strengthening Therapy Combined with Insulin Pumps for Type 2 Diabetes Mellitus with Qi-yin Deficiency
Bing JI ; Yadan WU ; Jianhua GUAN
Journal of Guangzhou University of Traditional Chinese Medicine 2000;0(04):-
0.05).The effect on traditional Chinese medical syndrome in the treatment group was superior to that in the control group(P 0.05).The average insulin dosage and hypoglycemia incidence were reduced,and the time for blood glucose becoming normal was shortened in the treatment group(P
9.HCMV inactivation of blood products by methylene blue photochemical treatment
Ping LU ; Bing LING ; Yuhua JI
Chinese Journal of Blood Transfusion 1988;0(04):-
Objective To observe the effects of methylene blue photochemical(MB-P) inactivation of human cytomegalovirus in blood products.Methods Plasma and red blood cell suspensions containing 10% HCMV and 5?mol/L MB were illuminated by fluorescent light of 38000 Lux for 1 hour, HCMV was used as model viruses for validation of virus inactivation.Results The 50% tissue culture infective dose (TCID_ 50 ) contained in plasma and red blood cell suspensions decreased by 4~6 times.Conclusion MB-P treatment is effective in inactivating the infectivity of HCMV in plasma and red blood cell suspension.
10.Permeability increase of prostate cancer cells membrane under low intensity ultrasound in vitro
Ji-zhen, ZHANG ; E, SHEN ; Bing, HU
Chinese Journal of Medical Ultrasound (Electronic Edition) 2010;07(12):2025-2030
Objective To investigate the permeability changes of prostate cancer cells membrane under low intensity ultrasound in vitro.Methods The culture of monolayer adherent LNCaP prostate cancer cells in six-well plate was exposed to continuous ultrasound at frequency of 1 MHz.The cells membrane permeability (stained with Calcein)and cells viability(stained with PI)were evaluated by fluorescent microscope (FM) and cells morphological changes were evaluated by scanning electron microscope (SEM) under ultrasound with acoustic intensity of 160 mW/cm2 for 5 s.The rate of cells with increased cells membrane permeability as function of acoustic intensity (80 mW/cm2,120 mW/cm2 and 160 mW/cm2,for 5 s) and exposure duration (5 s,10 s and 15 s,acoustic intensity of 120 mW/cm2) was evaluated by flow cytometry.ResultsAfter low intensity of ultrasound,the cells with increased cell membrane permeability could be clearly shown with Calcein uptake under FM while no cell showed Calcein uptake in the control group.The SEM showed less microvilli on the cells after low intensity of ultrasound exposure and few cells showed holes on the cell membrane.The rate of cells with increased membrane permeability increased with acoustic intensity and exposure duration.Conclusion Low intensity ultrasound alone could increase membrane permeability of prostate cancer cells and cells with increased membrane permeability showed surface plane,uncommon holes on the cells membrane.The rate of cells with increased membrane permeability positively correlated with acoustic intensity and exposure duration.