1.Effect of Digital Acupoint Pressure on Hemianesthesia in Patients after Stroke
Xianyu MAO ; Jianping HUANG ; Wenzong ZHU ; Fengjun SONG ; Bihong YE
Chinese Journal of Rehabilitation Theory and Practice 2016;22(10):1141-1144
Objective To observe the clinical effect of digital acupoint pressure on sensory dysfunction in hemiplegic patients after stroke. Methods From March to December, 2015, 60 hemiplegic patients with sensory dysfunction after stroke were randomly divided into control group and observation group with 30 cases in each group. The control group received routine rehabilitation exercise, while the obser-vation group received digital acupoint pressure in addition. Fugl-Meyer Assessment for Sense (FMA-S), Fugl-Meyer Assessment for Motor (FMA-M) and modified Barthel index (MBI) were used to evaluate the sensory dysfunction, motor function and activities of daily living be-fore and eight weeks after treatment. Results After treatment, the scores of FMA-S, FMA-M and MBI increased in both groups (t>6.430, P<0.01), and the scores were higher in the observation group than in the control group (t>2.100, P<0.05). Conclusion Digital acupoint pressure can facilitate the recovery of sensory dysfunction, improve the motor function and the activties of daily living in hemiplegic patients after stroke.
2.Effect of Losartan and Amlodipine on serum and urine transforming growth factor-beta 1 in kidney transplantation recipients
Tongqing CHEN ; Yingwei HUANG ; Yaozhong KONG ; Minwa LIN ; Bihong WU ; Guiying LIAN
Chinese Journal of Tissue Engineering Research 2009;13(53):10541-10544
OBJECTIVE: To investigate the effect of Losartan and Amlodipine on serum and urine transforming growth factor -β_1 in patients undergoing kidney transplantation. METHODS: A total of 40 patients with mild or moderate hypertension (systolic pressure 140-170 mm Hg, and diastolic pressure 85-100 mm Hg, 1 mm Hg=0.133 kPa) following primary kidney transplantation were selected from First People's Hospital of Foshan, including 23 males and 17 females aged (38.6±19.2) years. They were randomly divided into two groups (n=20): Losartan group (oral administration 50 mg per day) and Amlodipine group (oral administration 5 mg per day). The blood pressure of patients should be controlled below 130/80 mm Hg. The blood pressure, renal function, 24 h-proteinuria, serum and urine transforming growth factor-β_1 6 months after medication were observed. RESULTS: A total of 40 patients were included in the final analysis. The systolic pressure and diastolic pressure of patients were decreased after administration (P < 0.05) and decreased to normal levels 6 months after administration (P < 0.01). During treatment, there were significant differences in blood pressure decrease and mean arterial pressure between two groups (P > 0.05). No difference was found in total efficacy between two groups (P > 0.05). In addition, blood urea nitrogen, creatinine, and blood uric acid did not significantly alter after treatment in two groups (P > 0.05). After 6 months of treatment, 24 h-proteinuria, serum and urine transforming growth factor -β_1 in Losartan group were significantly decreased compared with before treatment (P < 0.05), while no obvious changes were found in Amlodipine group (P > 0.05). The 24 h-proteinuria, serum and urine transforming growth factor-β_1 in Iosartan group were significantly less than Amlodipine group (P < 0.05).CONCLUSION: Both Losartan and Amlodipine effectively controlled hypertension of patients following kidney transplantation, but Losartan significantly decreased 24 h-proteinuria, serum and urine transforming growth factor-β_1 compared with Amlodipine.
3.Evaluation of Sysmex XT-4000i automated hematology analyzer in count and classification of neonatal leukocytes
Jun MO ; Jianrong CHENG ; Xinliang LI ; Bihong HUANG ; Chisong FANG ; Hongyang TAN
International Journal of Laboratory Medicine 2015;(4):496-497,500
Objective To evaluate the accuracy of Sysmex XT-4000i automated hematology analyzer on neonatal leukocytes count and classification results.Methods 213 cases of neonatal blood specimens were analyzed respectively by Sysmex XT-4000i automated hematology analyzer and microscope counting and staining of two categories of methods.Results The instrument that immature granulocyte,primitive cell,shift to the left,three kind of tip in any one or more specimens have 112,accounted for 52.58% (112/213),and staining immature cell or shift to the left of the specimens was 91,accounted for 42.72% (91/213).The instrument to nucleated erythrocyte specimens were 109,accounting for 51.17% (109/213),and staining of nucleated erythrocyte were 66,accounting for 30.99% (66/213).Classify or classification of incomplete instrument failed to leukocytes were 11,ac-counting for 5.16% (11/213).When the specimens without nucleated erythrocytes interference or the number of nucleated eryth-rocytes is low [≤ 10/100 white blood cells(WBC)],Instruments on leukocyte count and manual counting results,there was not statistically significant differences between the two groups(P >0.05 ),when the sample number of nucleated erythrocytes (>10/100 WBC),When the specimens were nucleated erythrocyte number for a long time(>10/100 WBC),Instruments on leukocyte count and manual counting results,there was significant difference between the two groups(P <0.05).Correlation analysis on the instrument detection and manual dyeing classification of leukocytes,neutrophils,lymphocytes,monocytes,eosinophils,basophils, the correlation coefficient is respectively 0.95,0.93,0.78,0.86,0.14.Conclusion Some errors exist in Sysmex XT-4000i auto-mated hematology analyzer to count and classification of leukocytes.On neonatal blood tests should be carried out at the same time man-ual microscopy,and on the basis of nucleated erythrocytes were corrected,to ensure the clinical blood routine reporting results.
4.Evaluation of establishing and operating an electronic information management system at dialysis centers
Jianhua SHAO ; Jing CHEN ; Haiming LI ; Shensen LI ; Li YOU ; Bihong HUANG ; Yong GU ; Chuanming HAO ; Hong HUANG ; Jun LV
Chinese Journal of Hospital Administration 2012;28(7):514-517
Hemodialysis monitoring and information management software was used to establish an intelligent electronic system to manage hemodialysis patients' information,with hardware and software moderations.The electronic information management system for hemodialysis functioned steadily since 2008.This system changed not only the existing medical process of the center,but also contributed to safer treatments,more accurate operations of doctor’ s instructions,and better medical information records as well The results indicate that the electronic information management system in hemodialysis centers not only irnproves work efficiency and management quality significantly,but also effectively ensures the safety and caliber of hemodialysis treatment with less manpower costs.
5.Investigation on the natural infection of Theiler's murine encephalomyelitis virus and study on experimental infection of the virus in mice
Wen YUAN ; Yu ZHANG ; Bihong HUANG ; Yinzhu LUO ; Jing WANG ; Jinchun PAN ; Ruike WU ; Pengju GUO ; Ren HUANG
Chinese Journal of Comparative Medicine 2017;27(4):75-81
Objective To investigate the natural infection of Theiler's murine encephalomyelitis virus (TMEV) in mice,and to survey the distribution of virus in tissues and the changes of serum antibody in the experimentally TMEV-infected mice.Methods Enzyme linked immunosorbent assay (ELISA) and fluorescence quantitative RT-PCR (qRT-PCR) assay were used to detect the antibody and nucleic acid of TMEV in clinical samples.These samples included SPF mice collected from Guangdong area in 2010-2015,mice obtained from a non-barrier laboratory rodent colony,and wild Rattus norvegicus live-trapped around the non-barrier laboratory rodent colony.36 ICR mice were intracerebrally inoculated with TMEV BeAn strain.The clinical signs of the animals were observed daily post-inoculation.Three mice were euthanatized at day 0,3,7,10,17,21,31,39 and 46 post-inoculation (dpi),respectively.Tissue and serum samples were collected for TMEV detection.Results The TMEV antibody and nucleic acid positive rates of SPF mice collected from Guangdong area in 2010-2015 were 5.29% (n=2834) and 27.27% (n=457),respectively.The TMEV antibody and nucleic acid positive rates of the mice obtained from a non-barrier laboratory rodent colony were 71.95% (n=82) and 53.66% (n=82),respectively.The TMEV nucleic acid positive rate of wild Rattus norvegicus was 25.93% (n=27).In the TMEV positive mice,only two mice showed obvious clinical symptoms.The cecal contents,feces and brain samples were the best candidates for qRT-PCR assay.The viral nucleic acid could be detected in the brain,heart,liver,lung and stomach of ICR mice at 3 dpi,but no viral nucleic acid was detected in the spleen,kidney,and cecum.The viruses in liver,heart,lungs and stomach were completely cleared at 10 dpi,and the viruses persisted in the brain throughout the experiment.The TMEV antibody could be detected at 7 dpi,and then the antibody positive rate reached 100% at 17 dpi.The antibody level increased gradually and maintained up to 46 days.ICR mice showed latent infection after TMEV inoculation,with no obvious symptoms and eye pathological changes.Conclusions The experimental mice and wild Rattus norvegicus in Guangdong area are both infected with TMEV,and the infection rate is high.The mice inoculated with TMEV BeAn strain show latent infection.The TMEV antibody produced in mice can be detected at 7 dpi and persisted until the end of the experiment.The viruses are found in the liver,heart,lung and stomach for a short time,but are persisted in the brain for a long time.There is a good consistency of TMEV detection between qRT-PCR and ELISA.The qRT-PCR assay can be used as a powerful complement method for the national standard of laboratory animals.
6.A new formula of quantifying phosphate removal within one hemodialysis session
Mengjing WANG ; Haiming LI ; Huimin LIAO ; Yongfu YU ; Jianguo ZHU ; Bihong HUANG ; Li YUAN ; Chuanming HAO ; Jing CHEN
Chinese Journal of Nephrology 2012;28(9):673-678
Objective To report a simple formula to estimate phosphate removal by standard four-hour hemodialysis in Chinese patients.Methods A total of 165 MHD patients in Huashan Hospital were enrolled.Effluent dialysate samples were collected during treatment to estimate the total amount of phosphate removal.Pre-dialysis levels of serum phosphate,potassium (K+),hematocrit(Hct),parathyroid hormone(iPTH),carbon dioxide combining power(CO2CP),alkaline phosphatase (AKP),Kt/V,and ultrafiltration volume,age,gender,dry body weight,blood flow,phosphate clearance of dialyser,phosphate concentration of dialysate at 60 min after the start of HD were obtained.80% observations were randomly selected for formula building by backward stepwise and the remaining 20% observations were used to validate the formula.Results The formula was described as Tpo4 =88.6 ×C60-0.03 ×Age + 1.07 ×Gender +0.06 ×Clearance-4.59,where C60 was phosphate concentration in dialysate measured 60 min into HD and Clearance was the phosphate clearance of dialyser.Formula validation further suggested good predictive ability.Conclusion This study derives an approach to quantify phosphate removal by a simple formula,which will be helpful for clinicians to treat patient individually.
7.Early failure of arteriovenous fistula and its related factors and nursing
Wenwen LU ; Yanpei CAO ; Xiaoli YANG ; Bihong HUANG ; Xin WANG
Chinese Journal of Practical Nursing 2018;34(31):2418-2422
Objective The aim of the study was to investigate the early failure of newly created arteriovenous fistula(AVF) in patients on maintenance hemodialysis and the factors responsible for the failure. Methods The clinical data were retrospectively reviewed, preoperative examination and laboratory biochemical indicators of 88 patients with newly created AVF for maintenance hemodialysis in our hospital through Hospital Management Information System and telephone follow-ups. Binary Logistic regression was used to analyze the protective factors for early failure. Results In 88 patients, early failure of the AVF was found in 15 patients. Twenty-three factors, including gender, were involved in statistical analysis. There were statistical differences between the two groups in hypertension (χ2=7.689, P=0.006) and whether they had early referral to nephrologists (χ2=5.334, P=0.021). Further regression analysis showed hypertension ( OR=0.192, 95% CI=0.0538-0.692, P=0.012) was protective factor and without early referral ( OR=3.651, 95% CI=1.068-18.302, P=0.039) was the risk factor of early failure. Conclusion This study shows that no early referral and combined hypertension is an important factor affecting the early failure, emphasizing the clinical work, for the diagnosis of patients with chronic kidney disease, early nephrological referral should be established, and blood pressure monitoring should be done to help reduce the incidence of complications.
8.Establishment of a TaqMan real-time fluorescence quantitative PCR for detection of murine polyomavirus
Xueqin YIN ; Wen YUAN ; Jing WANG ; Bihong HUANG ; Dan RAO ; Miaoli WU ; Yujun ZHU ; Shengpeng FENG ; Pengju GUO ; Yu ZHANG ; Ren HUANG
Chinese Journal of Comparative Medicine 2015;(6):53-58
Objective To establish a rapid,specific and sensitive TaqMan real-time fluorescence quantitative PCR assay for detection of murine polyomavirus ( MPyV) .Methods The specific primers and TaqMan probe were designed based on genome sequence of MPyV.The primers amplified a 69 bp fragment.After optimizing the reaction system and reaction condition, the standard curve was plotted by detecting recombinant plasmid standards.The specificity, sensitivity and reproducibility of this method were evaluated.In addition, samples of lungs, spleens and feces obtained from experimentally infected mice and 86 clinical samples were used to validate the efficacy of this real-time PCR assay.Results The specificity assay showed that this assay could specifically detect MPyV and the sensitivity for MPyV was about 100 copies/well.The coefficients of variation ( CV) of both intra-assay and inter-assay were less than 1.13%.All of the samples from experimentally infected mice were positive for MPyV and 3 out of 86 clinical samples were positive by this TaqMan-PCR detection with a positive rate of 3.5%.Conclusions The real-time fluorescence quantitative TaqMan-PCR assay established in this study has high specificity, sensitivity and stability.It can be used for clinical diagnosis, routine detection and epidemiological investigation of murine polyomavirus infections.
9.Analysis on the occurrence and influencing factors of frequent intradialytic hypotension in hemodialysis patients
Xin WANG ; Yanpei CAO ; Xiaoli YANG ; Bihong HUANG ; Wenwen LU
Chinese Journal of Practical Nursing 2019;35(8):599-603
0bjective To investigate the occurrence of frequent intradialytic hypotension in hemodialysis patients and Analyzed influencing factors. Methods The 1 933 hemodialysis sections of 156 maintenance hemodialysis patients in the Huashan hospital affiliated to Fudan University in Shanghai were selected, and divided into frequent intradialytic hypotension and non- frequent intradialytic hypotension depending on whether the incidence of intradialytic hypotension is greater than 20%, and the patients' dialysis data and biochemical examination data are collected for the analysis of influencing factors. Results The incidence of frequent IDH in maintenance hemodialysis patients was 62.18%(97/156), and the pre-dialysis blood pressure of frequent IDH patients were higher than non-frequent IDH patients, frequent IDH patients: (134.02±21.01)/(73.85±10.73) mmHg(1 mmHg=0.133 kPa), non-frequent IDH patients: (124.66 ± 17.89)/(69.32 ± 10.65) mmHg, (t=-2.851,-2.558, P<0.05), but lower in post-dialysis, frequent IDH patients:(114.91±19.21)/(68.38±11.41) mmHg, non-frequent IDH patients: (127.90± 20.58)/(74.46±11.79) mmHg, (t=3.989, 3.189, P<0.01). Binary Logistic regression analysis showed that hemoglobin ( OR=0.354, P=0.015) and high-density lipoprotein ( OR=0.155, P=0.003) were protective factors for the occurrence of frequent IDH, and ultrafiltration volume/weight ( OR=6.021, P=0.002) and N-terminal pro-brain natriuretic peptide ( OR=2.687, P=0.020) were risk factors. Conclusions The incidence of frequent IDH in hemodialysis patients is high, and patients with high filtration rate, high N-terminal pro-brain natriuretic peptide, low hemoglobin and high density lipoprotein should be paid close attention to. It is recommended to regularly monitor patients' biochemical indicators, strengthen blood pressure monitoring for high-risk groups, and timely deal with the symptoms of low blood pressure.
10.A New Calculation Model for Calcium Requirements After Parathyroidectomy in Patients With Secondary Hyperparathyroidism
Ming CHENG ; Qian ZHANG ; Mengjing WANG ; Bihong HUANG ; Ye TAO ; Chunyan FAN ; Hongying WANG ; Minmin ZHANG
Clinical and Experimental Otorhinolaryngology 2023;16(3):282-289
Objectives:
. We aimed to develop a new calculation model for calcium requirements in dialysis patients following parathyroidectomy.
Methods:
. A total of 98 patients with secondary hyperparathyroidism receiving parathyroidectomy from January 2014 to January 2022 were enrolled in this study. Among these patients, 78 were randomly selected for construction of the calcium requirement calculation model, and the remaining 20 patients were selected for model validation. The calcium requirement model estimated the total calcium supplementation for 1 week after surgery using variables with significant relationships in the derivation group by stepwise multiple linear regression analysis. Bias, precision, and accuracy were measured in the validation group to determine the performance of the model.
Results:
. The model was as follows: calcium requirement for 1 week after surgery=33.798–8.929×immediate postoperative calcium+0.190×C-reactive protein–0.125×age+0.002×preoperative intact parathyroid hormone+0.003×preoperative alkaline phosphatase (R2=0.8). The model was successfully validated.
Conclusion
. We generated a novel model to guide calcium supplementation. This model can assist in stabilizing the serum calcium levels of patients during the early postoperative period. Furthermore, it contributes to the individualized and precise treatment of hypocalcemia in patients following parathyroidectomy.