This paper aims to establish a method for the determination of sulfur dioxide in sulfur fumigation Chinese herbs. Sample powder and hydrochloric acid solution were isolated by paraffin layer in order to avoid early reactions, with the generation of sulfur dioxide, headspace with airtight needle was used to transfer sulfur dioxide into gas chromatograph, and detected with thermal conductivity detector. The analytical performance was demonstrated by the analysis of 12 herbs, spiked at four concentration levels. In general, the recoveries ranging from 70% to 110%, with relative standard deviations (RSDs) within 15%, were obtained. The limit of detection (LOD) was below 10 mg x kg(-1). Standard addition can be used for low recovery samples. The method is simple, less time-consuming, specific and sensitive. Methods comparison revealed that gas chromatography is better than traditional titration in terms of method operability, accuracy and specificity, showing good application value.