1.Comparison of percutaneous coronary intervention versus conservative treatment in unstable angina pectoris
Chunyan HU ; Bei L ; Weifeng SHEN
Journal of Interventional Radiology 2001;0(05):-
0.05), but hospitalization duration was shorter in the invasive group than in the conservative group (10.3?5.6 days vs 14.6?10.7 days, P
2.Hepatitis Infection among Workers of Yellow River Bureau
Xiaohong YU ; Lili CAI ; Bei SONG ; Shufeng L
Chinese Journal of Nosocomiology 2006;0(05):-
OBJECTIVE To understand the condition of hepatitis B infection among workers of Yellow River Bureau.METHODS On March 2007 326 workers had the physical examination by ELA test in a hospital.RESULTS The positive rate was 11.4% among which HBsAg,HBeAg and HBcAb positive together accounted for 1.5%;HBsAg,HBeAb and HBcAb positive together accounted for 1.5%.CONCLUSIONS Screening hepatitis B and vaccine inoculation are important.
3.Value of transesophageal echocardiography in case selection of transthoracic minimally invasive device closure of ventricular septal defect
Si-lin, PAN ; Na, LIU ; Bei, L(U) ; Quan-sheng, XING ; Ke-feng, HOU ; Shu-hua, DUAN ; Qin, WU ; Zhi-xian, JI
Chinese Journal of Medical Ultrasound (Electronic Edition) 2012;09(6):504-506
Objective To evaluate the value of transesophageal echocardiography (TEE) in transthoracic minimally invasive device closure of ventricular septal defect(VSD).Methods A total of 164 cases of VSD were recruited as candidates to receive transthoracic minimally invasive device closure between January 2007 and October 2010,including 138 perimembranous VSDs,3 muscular VSDs and 23 supracristal VSDs.Among these groups,85 male patients were included.Four-champer view,five-champer view,left ventricular long-axis view,short-axis view and right ventricular inflow view were detected to evaluate the availability of device closure.Results A total of 152 cases(92.7%)were successfully closed with a device.All the patients were followed up more than 3 months arranged with a standard protocol.No complete atrioventricular block (CAVB) or associated valvular complications were observed.Three of the five cases with traced residual shunt after device closure closed spontaneously.Conclusion TEE plays an important role in transthoracic minimally invasive device closure of ventricular septal defect,which has been proved by the good follow-up results without CAVB and associated valvular complications.
4.Characterization and stability of S (-) pantoprazole sodium hydrates.
Chen BEI ; Zhang LIBO ; L I HONG ; Tang GUPING ; H U XIURONG
Journal of Zhejiang University. Medical sciences 2017;46(2):160-166
To study the characteristics and stability of new S(-) pantoprazole sodium hydrates.The X-ray single crystal diffractometer (SXRD), X-ray powder diffractometer (PXRD), thermogravimetric analysis (TG) and infrared spectrometry (IR) were used to characterize S(-) pantoprazole sodium hydrates. The stability of the hydrates was evaluated by high temperature test,affecting factors test and accelerated test.The crystalline water in S(-) pantoprazole sodium hydrates were very easy to lose and obtain, but crystal structure was not changed significantly. The transition from S(-) pantoprazole sodium trihydrate to S(-) pantoprazole sodium hemipentahydrate occurred at approximately 40 ℃ and reversible transitions from hemipentahydrate to trihydrate occurred at high humidity. Two hydrates had no significant difference in accelerated test.The crystal structure of the two hydrates are almost the same, hemipentahydrate is more stable than trihydrates at high temperature or at exposure to light(at 4500 ± 500 lx).