1.Analyzing the morphologic characteristics of pedicle-facet joints in lumbar spondylolysis: correlation with spinopelvic parameters and its clinical relevance
Baoqiang HE ; Yebo LENG ; Dejun ZHONG ; Yang LI ; Yehui LIAO ; Qiang TANG ; Chao TANG ; Fei MA ; Qing WANG
Chinese Journal of Orthopaedics 2024;44(3):177-185
Objective:To delineate the morphological features of pedicle-facet joints in lumbar spondylolysis patients, correlating these with spinopelvic parameters to explore their mechanisms and clinical implications.Methods:This study enrolled 121 patients with L 5 spondylolysis (IS group), 108 with L 4, 5 degenerative spondylolisthesis (DS group), and 100 with normal L 4, 5 but L 5S 1 lumbar disc herniation (NL group), who underwent radiography and multislice spiral CT from May 2020 to January 2023. Parameters including vertebral slip percentage (SP) and spinopelvic alignments, such as sacral slope and lumbar lordosis, were quantified using standing lateral lumbar radiographs. Morphological parameters of the L 4 and L 5 facet joints were measured on 3D reconstructed lumbar CT images, including the facet joint angle (FJA), pedicle-facet joint angle (PFA), facet joint osteoarthritis (OA), and facet joint tropism (FT). Results:The analysis revealed significant variances in SS and LL among the groups ( F=21.910, P<0.001; F=22.439, P<0.001). The IS group exhibited the highest SS and LL, followed by the DS and NL groups. Morphological assessments showed the largest L 4 FJA in the IS group, with progressive decreases in the DS and NL groups ( F=344.791, P<0.001). Conversely, L 4 PFA was greatest in the DS group ( F=193.725, P<0.001). Notably, L 4 OA was markedly more severe in the DS group compared to IS and NL groups ( H=467.925, P<0.001), with no significant disparity between IS and NL groups ( P>0.05). Correlation analyses within each cohort highlighted a negative association of sacral slope and lumbar lordosis with facet joint angles, yet a positive correlation with pedicle-facet joint angles both with statistical significance ( P<0.05). Furthermore, L 4 facet joint angles were consistently smaller than those at L 5, and L 4 pedicle-facet joint angles were larger than L 5 ( P<0.05). Osteoarthritis at L 5 was more pronounced in the IS group compared to L 4 ( Z=7.043, P<0.001), a trend inversely observed in the DS group ( Z=11.868, P<0.001), while the NL group showed no significant osteoarthritic variance between levels ( Z=0.556, P=0.578). Conclusion:Patients with lumbar spondylolysis demonstrate elevated sacral slope and lumbar lordosis, indicative of increased localized biomechanical stress in the lumbar spine. These alterations in the morphology of the pedicle-facet joints highlight the distinctive structural adaptations and potential strain distributions within this cohort.
2.Morphological characteristics of L 4, 5 facet joints in degenerative lumbar spondylolisthesis
Yebo LENG ; Chao TANG ; Dejun ZHONG ; Baoqiang HE ; Yehui LIAO ; Fei MA ; Qiang TANG ; Qing WANG
Chinese Journal of Orthopaedics 2023;43(8):508-515
Objective:To observe the morphological characteristics of L 4, 5 facet joints in patients with degenerative lumbar spondylolisthesis (DLS) of different spinopelvic types based on Roussouly classification. Methods:We retrospectively analyzed 142 patients with DLS who visited the department of orthopaedics in the Affiliated Hospital of Southwest Medical University from August 2018 to May 2022. There were 33 males aged 65.0±10.7 years and 109 females aged 61.8±9.6 years. The following morphological parameters of the L 4, 5 facet joint were measured on the CT images: facet joint angle (FJA), pedicle facet angle (PFA), facet joint tropism (FT) and facet joint osteoarthritis (OA) degree; the sacral slope (SS), lumbar lordosis (LL) and percentage of L 4 slip distance (SDP) were measured on preoperative standing neutral lumbar radiographs. According to the Roussouly classification, the patients were divided into four groups (type I, type II, type III, and type IV). The differences of morphological parameters of the facet joints and SDP were compared among the four groups, and the correlation between the FJA and PFA was analyzed. Results:There were 142 patients, including 28 type I, 50 type II, 43 type III, and 21 type IV according to the Roussouly classification. The SDPs of type I, type II, type III, and type IV were 19.1%±3.4%, 18.6%±3.9%, 21.7%±3.9%, 25.0%±2.4%, respectively. Except for types I and II, there were statistically significant differences in pairwise comparison among all other types ( P<0.05). The FJAs in type I and type II (31.4°±6.3°, 35.2°±6.8°) were larger than those in type III (28.4°±5.6°) and type IV (23.4°±4.5°), and the FJA in type III was larger than that in type IV. Conversely, the FJA in type I was smaller than that in type II. These differences were statistically significant ( P<0.05). The PFAs in type I and type II (113.9°±4.9°, 111.3°±5.6°) were smaller than those in type III (116.3°±4.4°) and type IV (121.8°±3.5°), and the PFA in type III was smaller than that in type IV, while, the PFA in type I was larger than that in type II. These differences were statistically significant ( P<0.05). The degree of OA in both type I and type II was lower than that in type III and type IV, with statistically significant differences ( P<0.05). However, there were no statistically significant differences in the degree of OA between type I and type II and between type III and type IV ( P> 0.05). Additionally, there were no statistically significant differences ( F=0.40, P=0.752) in the FT values among type I, type II, type III, and type IV (5.8°±2.3°, 5.6°±2.4°, 6.1°±1.8°, 5.9°±1.9°). Pearson correlation analysis showed that FJA was negatively correlated with PFA ( r=-0.68, P<0.001). Conclusion:In the slip segment of DLS, the facet joint morphology was part of the joint configuration in different spinopelvic types, not just the result of joint remodeling after DLS. Morphological characteristics of the facet joints and DLS interacted with each other.
3.Determination of residual impurities in pharmaceutical excipient cetomacrogol 1000 by gas chromatography
Haoyu LI ; Baoqiang TANG ; Dongsheng HE ; Jiasheng TU
Journal of China Pharmaceutical University 2022;53(3):293-299
For the quality control of cetomacrogol 1000, a gas chromatographic method for the determination of residual impurities in cetomacrogol 1000, such as ethylene oxide, 1, 4-dioxane, ethylene glycol, diethylene glycol and triethylene glycol, was established and validated.The DB-1 column with headspace injection was used to detect ethylene oxide and 1, 4-dioxane with the inlet temperature of 150 °C, the FID temperature of 250 °C, the headspace equilibration temperature of 70 °C and the equilibration time of 45 min.The VF-17MS column with liquid injection was used to detect ethylene glycol, diethylene glycol and triethylene glycol with the inlet temperature of 270 °C, and the FID temperature of 290 °C.The results showed that ethylene oxide and 1,4-dioxane have a good linearity within their specified addition amount ranges (r > 0.999), with the RSD of precision of below 8.0% and the average recovery rates of 90.6% and 101.2%; and that ethylene glycol, diethylene glycol and triethylene glycol also have a good linearity between 3 ? 60 μg/mL (r > 0.999), with the RSD of precision of below 3.0%, and the recovery rates of 96% ~ 103%.The method established in this study has good specificity, linearity, precision and recovery rate, which can effectively detect the multi-component and trace impurities.
4.Efficacy of conjoint fascial sheath and frontalis muscle flap suspension in treatment of congenital severe blepharoptosis: a systematic review and meta-analysis
Siming WEI ; Jiao CAO ; Yinke TANG ; Feng SUN ; Yang LI ; Xi ZHANG ; Baoqiang SONG
Chinese Journal of Medical Aesthetics and Cosmetology 2022;28(1):45-48
Objective:To evaluate the efficacy of combined fascia sheath suspension (CFS) and frontalis muscle flap suspension in the treatment of severe congenital blepharoptosis.Methods:We searched PubMed, EMbase, Cochrane Library, web of science and Chinese Hownet, Wanfang, VIP, CBM and other databases to collect randomized and non-randomized controlled trials comparing the efficacy of CFS and frontalis muscle flap suspension in the treatment of severe congenital ptosis, from the establishment of literature retrieval database to March 2020; two researchers used RevMan 5.3 software to select and exclude the literature, extract the data and evaluate the quality, set up appropriate effect index and conduct Meta-analysis.Results:Eleven studies included 661 patients, There were 312 cases in study group and 349 cases in control group. The results of Meta analysis showed that the OR of the two groups was 4.88 with 95% CI (2.69, 8.85); the OR of failure rate was 0.20, with 95% CI (0.11, 0.37); the OR of complications was 0.22, with 95% CI (0.14, 0.34). All three groups of data were statistically significant ( P<0.05). Conclusions:The available evidence shows that the combined fascia sheath suspension (CFS) is effective in the treatment of severe congenital blepharoptosis compared with frontalis muscle flap suspension, but the complications of CFS are lower and the satisfaction is higher; these findings have yet to be validated by more high-quality studies due to limitations in the quality and quantity of studies included.
5.Correlation between intervertebral disc degeneration and hyperuricemia
Yang LI ; Fei MA ; Yebo LENG ; Shicai XU ; Baoqiang HE ; Jiajun ZHOU ; Yehui LIAO ; Qiang TANG ; Chao TANG ; Qing WANG ; Dejun ZHONG
Chinese Journal of Tissue Engineering Research 2024;28(32):5091-5096
BACKGROUND:Hyperuricemia is a common metabolic disease,and the main clinical manifestation of patients with hyperuricemia is the formation of uric acid crystals leading to gout.Previous studies have only reported that uric acid crystals lead to intervertebral disc degeneration,but there are fewer studies on the correlation between hyperuricemia and intervertebral disc degeneration. OBJECTIVE:To retrospectively analyze the characteristics of intervertebral disc degeneration in patients with hyperuricemia and the correlation between serum uric acid level and intervertebral disc degeneration. METHODS:A retrospective analysis was performed in all patients diagnosed with intervertebral disc degeneration admitted at the Department of Orthopedics,the Affiliated Hospital of Southwest Medical University from January 2021 to December 2022.There were 97 hyperuricemia patients in the hyperuricemia group and 194 non-hyperuricemia patients in the control group according to sex and age in a ratio of 1:2.Blood uric acid test results were collected,and Pfirrmann scoring was performed for the degree of disc degeneration in patients based on the whole spinal MRI images.The difference in the degree of disc degeneration between the two groups was compared,and the correlation between the serum uric acid level and the degree of intervertebral disc degeneration was analyzed. RESULTS AND CONCLUSION:The Pfirrmann score in the hyperuricemia group was higher than that in the control group,and the total number of disc degeneration in the hyperuricemia group was also significantly higher than that in the control group(P<0.05).Spearman correlation analysis showed that the degree of disc degeneration in male patients was positively correlated with serum uric acid level at many spinal segments in the hyperuricemia group(C3/4:r=0.317,C4/5:r=0.333,C5/6:r=0.309,L2/3:r=0.443,P<0.05);the degree of disc degeneration in female patients was also positively correlated with serum uric acid level(C3/4:r=0.354,C4/5:r=0.388,C6/7:r=0.312,T7/8:r=0.282,T9/10:r=0.305,T11/12:r=0.277,L4/5:r=0.319,L5-S1:r=0.367,P<0.05).In the control group,there was no significant correlation between the degree of disc degeneration and serum uric acid level in male and female patients(P>0.05).To conclude,in patients with hyperuricemia,the higher serum uric acid level indicates the more serious intervertebral disc degeneration.Therefore,hyperuricemia is one of the risk factors for intervertebral disc degeneration.