1.Design and Implement of the ECLSS Adaptive Learning Intelligent Decision Support System
Yibing DENG ; Jie BA ; Wei HU ; Junyi SHEN
Space Medicine & Medical Engineering 2006;0(01):-
Objective To monitor state of environment control and life support system (ECLSS), and to diagnose faults and provide decision support in manned space flight. Methods According to the principle of decision support system, neural networks and the expert system, the foundational constructional structure and work flow of the ECLSS decision support system(EDSS) were designed,fault tree analyze(FTA) method was used to sort all of the faults and to form the expert knowledge framework, expert system and neural networks were integrated to adaptive learning from experience. Results In the two-men-five-days SZ-6 manned space flight, this software system worked well, and had reduced the difficulty and intensity of ground flight control and had provided good technological support for the consummation of this flight. Conclusion For the first time, the ECLSS decision support system is designed and implemented by using database and expert system technology. It can judge parameters state and diagnose faults exactly and rapidly, and the data models are designed correctly to give the rational result of parameter prediction.
2.MRI of portal vein and superior mesenteric venous thrombosis with intestinal ischemia
You-Fa MO ; Xue-Lin ZHANG ; Li-Juan ZHANG ; Xiang-Liang LI ; Ba-Shen HU ;
Chinese Journal of Radiology 2001;0(02):-
Objective To discuss the diagnostic value of MRI for portal vein(PV)and superior mesenteric venous(SMV)thrombosis.Methods Twelve patients with portal vein and superior mesenterie venous thrombosis proved by operation and pathology were examined with T_1WI,T_2WI,T_2-weighted fat suppression imaging,MR angiography(MRA)and Gd-DTPA enhanced dynamic MRI.Results Signals in PV and SMV were detected on T_1 WI and T2WI in 12 cases;3 acute thrombus presented hypo-or isointense on T_1 WI and hyperintense on T_2 WI.ttyperintense on T_1 WI and T_2WI were showed in 8 subacute thrombus; 1 chronic thrombus presented heterogenous intense on T_1W1 and hypointense on T_2W1.No enhancement within PV and SMV was found on Gd-DTPA enhanced images.Bowel dilatation was found in 10 cases,bowel hemorrhage in 6,bowel wall thickening in 12,intestinal pneumatosis in 3,ascites in 12,cavernous transformation of the portal vein in 3,hepatic perfusion disorder in 6.Conclusion MRI is an important and sensitive imaging method for the diagnosis and location of portal vein and superior mesenteric venous thrombosis with intestinal ischemia.
3.Risk factors of bronchopulmonary dysplasia in very preterm infants: a national multicenter study
Ruihua BA ; Lixia TANG ; Wei SHEN ; Lian WANG ; Zhi ZHENG ; Xinzhu LIN ; Fan WU ; Qianxin TIAN ; Qiliang CUI ; Yuan YUAN ; Ling REN ; Jian MAO ; Yumei WANG ; Bizhen SHI ; Ling LIU ; Jinghui ZHANG ; Yanmei CHANG ; Xiaomei TONG ; Yan ZHU ; Rong ZHANG ; Xiuzhen YE ; Jingjing ZOU ; Huaiyu LI ; Baoyin ZHAO ; Yinping QIU ; Shuhua LIU ; Li MA ; Ying XU ; Rui CHENG ; Wenli ZHOU ; Hui WU ; Zhiyong LIU ; Dongmei CHEN ; Jinzhi GAO ; Jing LIU ; Ling CHEN ; Cong LI ; Chunyan YANG ; Ping XU ; Yayu ZHANG ; Sile HU ; Hua MEI ; Zuming YANG ; Zongtai FENG ; Sannan WANG ; Eryan MENG ; Lihong SHANG ; Falin XU ; Shaoping OU ; Rong JU
Chinese Pediatric Emergency Medicine 2022;29(6):433-439
Objective:To analyze the risk factors of bronchopulmonary dysplasia(BPD)in very preterm infants(VPI), and to provide scientific basis for the prevention and treatment of BPD in VPI.Methods:A prospective multicenter study was designed to collect the clinical data of VPI in department of neonatology of 28 hospitals in 7 regions from September 2019 to December 2020.According to the continuous oxygen dependence at 28 days after birth, VPI were divided into non BPD group and BPD group, and the risk factors of BPD in VPI were analyzed.Results:A total of 2 514 cases of VPI including 1 364 cases without BPD and 1 150 cases with BPD were enrolled.The incidence of BPD was 45.7%.The smaller the gestational age and weight, the higher the incidence of BPD( P<0.001). Compared with non BPD group, the average birth age, weight and cesarean section rate in BPD group were lower, and the incidence of male infants, small for gestational age and 5-minute apgar score≤7 were higher( P<0.01). In BPD group, the incidences of neonatal respiratory distress syndrome(NRDS), hemodynamically significant patent ductus arteriosus, retinopathy of prematurity, feeding intolerance, extrauterine growth restriction, grade Ⅲ~Ⅳ intracranial hemorrhage, anemia, early-onset and late-onset sepsis, nosocomial infection, parenteral nutrition-associated cholestasis were higher( P<0.05), the use of pulmonary surfactant(PS), postnatal hormone exposure, anemia and blood transfusion were also higher, and the time of invasive and non-invasive mechanical ventilation, oxygen use and total hospital stay were longer( P<0.001). The time of starting enteral nutrition, cumulative fasting days, days of reaching total enteral nutrition, days of continuous parenteral nutrition, days of reaching 110 kcal/(kg·d) total calorie, days of reaching 110 kcal/(kg·d) oral calorie were longer and the breastfeeding rate was lower in BPD group than those in non BPD group( P<0.001). The cumulative doses of amino acid and fat emulsion during the first week of hospitalization were higher in BPD group( P<0.001). Multivariate Logistic regression analysis showed that NRDS, invasive mechanical ventilation, age of reaching total enteral nutrition, anemia and blood transfusion were the independent risk factors for BPD in VPI, and older gestational age was the protective factor for BPD. Conclusion:Strengthening perinatal management, avoiding premature delivery and severe NRDS, shortening the time of invasive mechanical ventilation, paying attention to enteral nutrition management, reaching whole intestinal feeding as soon as possible, and strictly mastering the indications of blood transfusion are very important to reduce the incidence of BPD in VPI.
4.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve