1.Ankle Fractures: The Operative Outcome
Ahmad Hafiz Z ; Nazri MY ; Azril MA
Malaysian Orthopaedic Journal 2011;5(1):40-43
Ankle fractures are commonly seen in orthopaedic practice. This retrospective study of patients with ankle fractures who underwent surgical treatment in our institution from January 2000 to December 2003 was undertaken to analyze the common causes and patterns of ankle fractures; and the functional outcome of operative treatment for these fractures. Eighty patients were identified and reviewed. There were 65 male (81.3%) and 15 female patients (18.7%) with age ranging from 13 to 71 years old (mean, 32.3y).
Orthopaedic
2.Intertrochanteric fracture fixation with Dynamic Hip Screw: Is tip-apex distance measurement useful for predicting fixation failure?
Goh KL ; Zamzuri Z ; Mohd Ariff S ; Mohamed Azril MA
The International Medical Journal Malaysia 2016;15(1):31-34
Introduction: Application of dynamic hip screw (DHS) implant for the treatment of unstable
intertrochanteric fractures continues to raise concern related to risk of lag screw cut-out with or without
subsequent damage to the acetabulum. Measurement of tip-apex distances (TAD) has been recommended to
guide the optimal placement of lag screw and to predict subsequent risk of screw cut-out. In this study, the
value of TAD was evaluated to verify its usefulness. Methods: This is a retrospective study of 33 consecutive
patients with intertrochanteric fracture treated with DHS. Demographic data of the patients were traced
from their case notes. Post-operative radiographs were reviewed by focusing on measurement of TAD on
anteroposterior and lateral radiographs. Radiographs at one year follow-up were reviewed to depict any
fixation-related failure or complication. Results: Fifty two percent of patients did not achieved the
recommended TAD of ≤ 25mm. The mean post-operative TAD was 25.9mm and elderly patients were likely
to achieve TAD of ≤ 25mm. The overall complication rate of 6% was attributed to screw cut-out in two
cases. The unstable left-sided fracture was identified to be a potential risk for screw cut-out or migration.
Conclusion: TAD is a valuable measurement to guide optimal placement of lag screw during DHS fixation of
intertrochanteric fracture.
3.Primary Fixation of AO Type-C Fracture of the Distal Radius with Volar Locking Plates. A Cross-Sectional Study of Patient Rated Outcomes at Hospital Tengku Ampuan Afzan
Mohd Sallehuddin H ; Zamzuri Z ; Ariff MS ; Mohd Shukrimi A ; Mohamed Azril MA ; Nazri MY
The International Medical Journal Malaysia 2014;13(2):3-6
This is a cross-sectional study of 37 patients with AO type C (complete intra-articular) fractures
of the distal radius, evaluating the functional, anatomical, and patient rated outcomes one year after primary
fixation with a volar locking plate. Methods: Functional outcomes were assessed based on the grip strength, and
the range of motion of forearm and wrist. Anatomical outcomes were assessed based on the radial inclination,
radial height, volar tilt, and articular step or gap. Patient rated outcome was measured with a Disability of
arm, shoulder and hand (DASH) questionnaire. Results: One year after surgery, 24 (64%) patients achieved good
and excellent anatomical results, and DASH scores were acceptable in 73% of patients. Most of the patients
had achieved 80% of their grip strength. The mean DASH score of 12.3 was comparable with other studies. Grip
strength, radial inclination and volar tilt had a significant correlation with the DASH score. Conclusion: Volar
locking plates can be used to achieve optimal reduction in all three parameters in the treatment of AO type C
fractures of the distal radius. Versatile fracture fragment reduction and angular stability enable rehabilitation
hence obtaining good functional outcomes.
4.Delayed Bowel Perforation: A Pitfall Of Surgical Management Of Sacral Chordoma
Kow RY ; Goh KL ; Mohamed Azril MA ; Low CL ; Fadhli M
Malaysian Orthopaedic Journal 2018;12(Supplement A):90-