1.Simultaneous quantitation of atorvastatin and its two active metabolites in human plasma by liquid chromatography/(-) electrospray tandem mass spectrometry
Partani Pankaj ; Verma Manaswita S. ; Gurule Sanjay ; Khuroo Arshad ; Monif Tausif
Journal of Pharmaceutical Analysis 2014;(1):26-36
A sensitive, accurate and selective liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for the simultaneous quantitation of atorvastatin (AT) and its equipotent hydroxyl metabolites, 2-hydroxy atorvastatin (2-AT) and 4-hydroxy atorvastatin (4-AT), in human plasma. Electrospray ionization (ESI) interface in negative ion mode was selected to improve the selectivity and the sensitivity required for this application. Additionally, a solid phase extraction (SPE) step was performed to reduce any ion-suppression and/or enhancement effects. The separation of all compounds was achieved in less than 6 min using a C18 reverse-phase fused-cores column and a mobile phase, composed of a mixture of 0.005%formic acid in water:acetonitrile:methanol (35:25:40, v/v/v), in isocratic mode at a flow rate of 0.6 mL/min. The method has lower limit of quantitation (LLOQ) of 0.050 ng/mL for all analytes. The method has shown tremendous reproducibility, with intra-and inter-day precision less than 6.6%, and intra- and inter-day accuracy within 74.3% of nominal values, for all analytes, and has proved to be highly reliable for the analysis of clinical samples.
2.Liquid chromatography-tandem mass spectrometry method for the estimation of adefovir in human plasma:Application to a pharmacokinetic study
Dipanjan GOSWAMI ; Sanjay GURULE ; Arabinda SAHA ; Poonam VATS ; Arshad KHUROO ; Tausif MONIF
Journal of Pharmaceutical Analysis 2015;(3):190-199
An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d4 was used as an internal standard and Synergi MAX RP80A (150 mm × 4.6 mm, 4μm) column provided the desired chromatographic separation of compounds followed by detection with mass spectrometry. The method used simple isocratic chromato-graphic condition and mass spectrometric detection in the positive ionization mode. The calibration curves were linear over the range of 0.50–42.47 ng/mL with the lower limit of quantitation validated at 0.50 ng/mL. Matrix effect was assessed by post-column infusion experiment to monitor phospholipids and post-extraction addition experiment was performed. The degree of matrix effect for adefovir was determined as 7.5%and ion-enhancement in five different lots of human plasma was 7.1%and had no impact on study samples analysis with 4.5 min run time. The intra- and inter-day precision values were within 7.7% and 7.8%, respectively, for adefovir at the lower limit of quantification level. Validated bioanalytical method was successfully applied to clinical sample analysis.