1. Immunohistochemistry of prostate carcinoma
Erdenetuya N ; Amgalanzaya E ; Tsengelmaa J ; Erdenetsogt D ; Galtsog L
Innovation 2014;8(3):46-48
BACKGROUNDProstate cancer is the most frequent malignancy among men nowadays.METHODSImmunohistochemical expression of prostate-specific antigen (PSA) was retrospectively investigated in 10 patients admitted with clinical suspicion of the prostate cancer. Slides were collected from archived biopsiesandthey were stained for PSA.The final reaction product was evaluated as negative (0), weak/moderate positive (1), and intense positive (2).RESULTSGlandular prostate carcinoma was found in 40% (n=4) and undifferentiated carcinoma in 60% (n=6). The immunoreaction for PSA was intense positive in 30% (n=3), weak/moderate positive in 50% (n=5) and negative in 20% (n=2) of total cases.CONCLUSIONSWe concludethat PSA immunoreaction is helpful for the differential diagnosis based on our results.
2.A comparison of PCR and LAMP methods for detecting shiga toxin producing Escherichia coli
Nyamtuya N ; Sarantuya J ; Munkhdelger Ya ; Amgalanzaya D
Mongolian Medical Sciences 2022;200(2):3-7
Introduction:
PCR to detect and amplificate the virulence genes of STEC is specific and more sensitive, however, it takes five to six hours for whole test procedure and requires special lab instruments such as thermocycler. Loop-mediated isothermal amplification is a simple, rapid, specific and cost-effective nucleic acid amplification method by using four to six primers when compared to PCR, nucleic acid sequence-based amplification, self-sustained sequence replication and strand displacement amplification.
Materials and Methods:
In our study, we analyzed comparison of PCR and LAMP results on standard strain used quality control strain solution which diluted 1pg/µL DNA, 10 pg/µL DNA, 100 pg/µL DNA, 1 ng/μL DNA, 10 ng/μL DNA, and 100 ng/μL DNA concentration from LB agar cultures.
Research ethics:
Permission to submit the survey was granted by the Ethics Review Committee of the MNUMS and the survey was conducted in accordance with the rules and regulations.
Goal:
Detection and comparison of STEC by PCR and LAMP
Result:
Sensitivity of Stx1 and stx2 genes in PCR results are positive in 10 pg/µL DNA solution and
negative in 1pg/µL DNA. In LAMP test results showed that positive for all concentration. It
shows that LAMP method sensitivity is 10 times more than PCR.
Conclusion
It shows that LAMP method sensitivity is 10 times more than PCR. All in allLAMP test is cost
effective test with sensitive for detection STEC.
3.A comparison of PCR and LAMP methods for detecting shiga toxin producing escherichia coli
Nyamtuya N ; Sarantuya J ; Amgalanzaya D ; Munkhdelger Ya
Mongolian Medical Sciences 2022;201(3):3-6
Introduction:
PCR to detect and amplificate the virulence genes of STEC is specific and more sensitive, however, it takes five to six hours for whole test procedure and requires special lab instruments such as thermocycler. Loop-mediated isothermal amplification is a simple, rapid, specific and cost-effective nucleic acid amplification method by using four to six primers when compared to PCR, nucleic acid sequence-based amplification, self-sustained sequence replication and strand displacement amplification.
Goal:
Detection and comparison of STEC by PCR and LAMP
Materials and Methods:
In our study, we analyzed comparison of PCR and LAMP results on standard strain used quality control strain solution which diluted 1pg/µL DNA, 10 pg/µL DNA, 100 pg/µL DNA, 1 ng/μL DNA, 10 ng/μL DNA, and 100 ng/μL DNA concentration from LB agar cultures.
Research ethics:
Permission to submit the survey was granted by the Ethics Review Committee of the MNUMS and the survey was conducted in accordance with the rules and regulations.
Result:
Sensitivity of Stx1 and stx2 genes in PCR results are positive in 10 pg/µL DNA solution and negative in 1pg/µL DNA. In LAMP test results showed that positive for all concentration. It shows that LAMP method sensitivity is 10 times more than PCR.
Conclusion
It shows that LAMP method sensitivity is 10 times more than PCR. All in allLAMP test is cost effective test with sensitive for detection STEC.