1.Clinical value of neuro-electrophysiological measure in Guillain-Barre syndrome
Ying WANG ; Wenhong HAN ; Aibing REN
Journal of Chinese Physician 2012;14(4):458-460
ObjectiveTo explore the characteristics of neuro-electrophysiology and clinical value in patients with Guillain-Barre syndrome.MethedsWe performed retrospective analysis of the clinical date of 46 patients with Guillain-Barre syndrome in our hospital.Hughes grades and neuro-electrophysiological measure including motor conduction velocity (MCV),complex muscle action potential (CMAP),sensory conduction velocity (SCV) and F wave,were investigated as the related factors with the prognosis of GBS.Results The rate of abnormal F wave was higher than the rate of abnormal MCV.The rate of abnormal SCV was lower than the rate of abnormal F wave and MCV( P <0.05).The prognosis of the acute inflammatory demyelinating polyneuropathy (AIDP) group was superior to the acute motor axonal neuropathy (AMAN) group,and there had significant difference( P <0.05).ConclusionsThe neuro-electrophysiological investigation is an important way to diagnose the GBS.F wave is a sensitive and specify index in the early diagnosis of GBS.The neuro-electrophysiological observation of MCV and CMAP may be served as cues for diagnosis,determination of the subtype and evaluation of the treatment effect in GBS.
2.Determination of the Level of Sodium Ferulate in Plasma by HPLC
Zhiqiang REN ; Lijun LIU ; Aibing LONG ; Xianwei LI
China Pharmacy 1991;0(01):-
OBJECTIVE:A HPLC method was established for determination of the level of sodium ferulate in plasma.ME_THODS:A C18 radial compression column was used with a mobile phase of CH3OH∶H2O∶H3PO4(250∶250∶0.2).The detecing wavelength was 254nm.RESULTS:The linear range was 1.2~24?g/ml(r=0.9 993).The average recovery was(98.8?0.6)%.The RSDs of within-day and between-day were less than 10%.CONCLUSION:This method provides an accurate and sensitive way in detecting plasma concentration of sodium ferulate.
3.Application of a New Vierordt Method to the Assay of Ingredients in Two Compound Fleroxacin Preparations
Zhiqiang REN ; Hong JIANG ; Aibing LONG ; Xianwei LI ; Kewu XIAO
China Pharmacy 2001;0(11):-
OBJECTIVE:To establish a New Vierordt method for assaying ingredients in compound fleroxacin suppositories and compound fleroxacin ear drops METHODS:New Vierordt method was applied to determination of fleroxacin and tinidazole in compound fleroxacin suppositories and fleroxacin and metronidazole in compound fleroxacin ear drops with no need of separation RESULTS:The fleroxacin and tinidazole in compound fleroxacin suppositories were detected at wavelength 286nm and 317nm respectively The average recoveries were 100 17% and 99 96% with RSDs=0 44% and 0 37% respectively The fleroxacin and metronidazole in the compound fleroxacin ear drops were detected at wavelength 286nm and 318nm respectively The average recoueries were 100 65% and 99 92% with RSDs=0 65% and 0 21% respectively CONCLUSION:The New Vierordt method can be used for quality control of the two compound preparations because of its convenience,accuracy and good repeatability and can eliminate mutual interference of two ingredients in preparations
4.Determination of Residues of 5 Organic Solvents in Teicoplanin Raw Material and Injection by Headspace GC
Wenfei GENG ; Junying WU ; Chunxia WANG ; Lemin REN ; Aibing KE
China Pharmacy 2015;(18):2554-2556
OBJECTIVE:To establish the method for the residues determination of 5 organic solvents in teicoplanin raw materi-al and injection. METHODS:Headspace GC was performed on the column with 6% cyanopropylphenyl-94% dimethyl polysiloxane (DB-624)as the stationary phase capillary column,the carrier gas was nitrogen,using the temperature program. The temperature of inlet was 200 ℃,detector was hydrogen flame ionization detector with the flow rate of 1 ml/min,split ratio was 40 ∶ 1 and the vol-ume was 1 ml. RESULTS:Good linearity of ethanol,acetone,ethyl acetate,tetrahydrofuran and triethylamine were obtained(r were 0.999 0-0.999 3);the average recoveries were respectively 95.6%,97.0%,103.2%,94.3%and 98.2%(RSD were 2.1%-4.9%, n=9);RSDs of precision and repeatability tests ≤2.6%;and the minimum detectable concentration were respectively 2,2,2,0.7 and 0.3 μg/ml. CONCLUSIONS:The established method is rapid,sensitive and accurate,and can be used for the residues determi-nation of organic solvents in teicoplanin raw materials and injection.