1.Effectiveness analysis of "tail compression fixation+suture bridge" technology under shoulder arthroscopy for treating primary tear in medial enthesis of rotator cuff.
AIKEREMU AIERKEN ; Qiangqiang LI ; Kai FU ; Dongyang CHEN ; Yao YAO ; Ying SHEN ; Qing JIANG ; Jianghui QIN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(5):561-565
OBJECTIVE:
To investigate the feasibility and effectiveness of "tail compression fixation+suture bridge" technology under shoulder arthroscopy for treating primary tear in medial enthesis of rotator cuff.
METHODS:
The clinical data of 11 patients with primary tear in medial enthesis of rotator cuff who met the selection criteria between October 2020 and October 2022 were retrospectively analyzed, including 3 males and 8 females, aged 39-79 years, with an average of 61.0 years. Rotator cuff injury was caused by traumatic fall in 8 cases, and the time from injury to admission was 1-4 months, with an average of 2.0 months; the remaining 3 cases had no obvious inducement. The active range of motion of the affected shoulder was limited, with an active forward flexion range of motion of (64.1±10.9)°, abduction of (78.1±6.4)°, internal rotation of (48.2±6.6)°, and external rotation of (41.8±10.5)°; 5 cases had shoulder stiffness. The preoperative visual analogue scale (VAS) score was 7.8±0.8 and the American Society of Shoulder and Elbow Surgeons (ASES) score was 23.9±6.4. The patients were treated with "tail compression fixation+suture bridge" technology under shoulder arthroscopy, and the pain and functional recovery were evaluated by VAS score, ASES score, and active range of motion of shoulder joint at last follow-up; MRI was performed after operation, and the integrity of rotator cuff was evaluated by Sugaya classification system.
RESULTS:
All the 11 patients were followed up 2-22 months, with an average of 13.5 months. All incisions healed by first intention, and there was no complication such as infection, rotator cuff re-tear, and anchor falling off. At last follow-up, the VAS score was 0.8±0.7 and the ASES score was 93.5±4.2, which significantly improved when compared with those before operation ( P<0.05). All 11 patients had no significant swelling in the shoulders, and the active range of motion was (165.1±8.8)° in flexion, (75.3±8.4)° in abduction, (56.6±5.5)° in internal rotation, and (51.8±4.0)° in external rotation, which significantly improved when compared with those before operation ( P<0.05). Shoulder MRI showed adequate tendon thickness and good continuity in 9 cases, including 4 cases with partial high signal area; and 2 cases with inadequate tendon thickness but high continuity and partial high signal area. According to Sugaya classification system, there were 4 cases of type 1 (36.4%), 5 cases of type 2 (45.5%), and 2 cases of type 3 (18.1%).
CONCLUSION
For the patients with primary tear in medial enthesis of rotator cuff, the "tail compression fixation+suture bridge" technology under shoulder arthroscopy is simple and effective.
Male
;
Female
;
Humans
;
Rotator Cuff/surgery*
;
Shoulder
;
Arthroscopy
;
Retrospective Studies
;
Treatment Outcome
;
Rotator Cuff Injuries/surgery*
;
Rupture
;
Shoulder Joint/surgery*
;
Sutures
;
Range of Motion, Articular