1.Application of CAE technology in CT products' development.
Chinese Journal of Medical Instrumentation 2008;32(3):215-217
Taking a typical-structure CT patient table as an example, methods of CAE applications to its design are introduced in detail in this paper, and theoretical analysis for the design result is made. This has provided a precise, efficient and reliable method for CT patient tables' mechanical designing.
Equipment Design
;
Tomography, X-Ray Computed
;
instrumentation
2.Malfunction analysis and preventive measures of CT equipment.
Chinese Journal of Medical Instrumentation 2011;35(4):307-309
After the analysis of the service and maintenance technology of CT equipment under the existing technical condition we conclude that although the CT equipment malfunctions vary with different manufacturer, they are predictable and preventable, based on the identical CT principle and similar construction of system.
Equipment Failure
;
Tomography, X-Ray Computed
;
instrumentation
3.COSMOS motion design optimization in the CT table.
Hong SHANG ; Jian HUANG ; Chao REN
Chinese Journal of Medical Instrumentation 2013;37(2):106-108
Through the CT Table dynamic simulation by COSMOS Motion, analysis the hinge of table and the motor force, then optimize the position of the hinge of table, provide the evidence of selecting bearing and motor, meanwhile enhance the design quality of the CT table and reduce the product design cost.
Equipment Design
;
Tomography, X-Ray Computed
;
instrumentation
4.Analysis of Factors on Clinical Application of Vehicle CT Shelter.
Wanjun SHUAI ; Yong CHAO ; Shuai LIU ; Can DONG ; Huayong GAO ; Shulin TAN ; Fu NIU
Chinese Journal of Medical Instrumentation 2015;39(5):380-382
To assure the clinical quality and requirement of CT shelter used in field environment, the factors related with the practical application were studied. The evaluation indicators of CT equipment were investigated. Based on the technical modification of vehicle shelter CT, the scanning conditions of shelter CT were analyzed. Moreover, the comparative study was done between shelter CT and common CT in hospitals. In result, in order to meet maneuverability application in the field, vehicle shelter CT was restrictive by the field conditions, traffic impacts and running requirement. The application of vehicle shelter CT was affected by the factors, such as mechanical stabilization, moving precision, power fluctuations and variations of temperature and humidity, etc. The results were helpful to improve the clinical quality of vehicle shelter CT and made a base for the quality control study in the future.
Humidity
;
Temperature
;
Tomography, X-Ray Computed
;
instrumentation
5.Method and application for improving the load capacity of CT diagnosis table top.
Di WANG ; Ruixia ZHANG ; Fen LI
Chinese Journal of Medical Instrumentation 2014;38(2):152-153
In the load capacity test of CT diagnosis table top, by analyzing the easy destroy area and related test data for the table top, using a simple mechanical auxiliary support structure in local area of the table top to solve the insufficient loading strength problem of table top and obtain significant results during the actual product usage.
Tomography, X-Ray Computed
;
instrumentation
;
methods
6.Phantom holder of CT couch.
Ruixia ZHANG ; Hongyu ZHAN ; Di WANG
Chinese Journal of Medical Instrumentation 2014;38(2):117-129
This article describes a phantom holder in CT couch which adjusted easily and accurately, installed easily. The holder mainly include removing and locking equipment between phantom holder and table top, move horizontally equipment between left and right, rotating equipment between left and right. After holder and table top fixed one part, holder with phantom can move horizontally, front and back, rotate between left and right in a small angle, in order to make operator test phantoms accurately and easily. At the same time, this phantom holder realized free adjustment after first adjustments, which shortened operator work time.
Equipment Design
;
Tomography, X-Ray Computed
;
instrumentation
7.Error analysis and solution with different attenuation of CT bed and radiotherapy bed.
Chinese Journal of Medical Instrumentation 2014;38(1):75-75
Existence of rays with different decay rate between radiotherapy CT bed and radiotherapy bed, this paper discusses the rate induced and identified two kinds of simple solution.
Equipment Failure
;
Radiotherapy
;
instrumentation
;
Tomography, X-Ray Computed
;
instrumentation
8.Research of working condition monitoring and analyzing system for rotating anode X-ray tube based on the vibration measurement.
Hao WU ; Weidong WANG ; Yong YAN ; Shuai ZHANG ; Hefei ZU ; Weibin CHEN
Chinese Journal of Medical Instrumentation 2011;35(1):28-31
A non-invasive detecting and analyzing method which used to monitor the working condition of rotating anode X-ray was proposed. Based on the NI development environment, accelerometer, 24-bit high resolution data acquisition card and personal computer were connected to construct the system for collecting the vibration signal of X-ray tube. Results demonstrate that the system could acquire and store the vibration data of X-ray tube quickly and efficiently. The characteristics of vibration, were extracted and processed, which proposed a new approach to detect the malfunction of rotating anode X-ray early and effectively.
Equipment Design
;
Software
;
Tomography, X-Ray Computed
;
instrumentation
;
methods
;
Vibration
9.CT scan optimization in SPECT/CT equipment of nuclear medicine.
Chinese Journal of Medical Instrumentation 2013;37(4):308-310
OBJECTIVEIn order to reduce patients' radiation doses and decrease the exposure time of the CT Tube. By summarizing experiential methods from the previous practice work, we hope to draw an optimized scheme of CT scanner.
METHODSWe analyzed the continuous clinical examples in four months, changed the different levels of parameters slowly, optimized acquisition conditions and retrospected the CT radiative dose. In the meantime, we counted the monthly CT Bulb exposure time, exposure time per capita tube data and so on.
RESULTSCompared with former result, the average CT radiative dose per person is decreased 84.72%, which conventional bone, the small joints of the bone, the brain and the heart radiation reduced respectively 83.82%, 88.80%, 86.78% and 84.49%, and the differences are statistically significant. The exposure time of optimized CT Tube is 2 031 s.
CONCLUSIONSUsing the CT scan optimization scheming has great efforts in the practice of clinical nuclear medicine, can reduce the exposure time of the CT Tube and improve the lifetime of the bulb. Therefore, it can be widely used.
Humans ; Nuclear Medicine ; instrumentation ; Radiation Dosage ; Tomography, Emission-Computed, Single-Photon ; instrumentation ; Tomography, X-Ray Computed ; instrumentation
10.Design and implementation of a VB-based virtual operation system for the console in an x-ray machine.
Hui-qin LIU ; Kai DONG ; Bin YANG ; Yun-xi CAO
Chinese Journal of Medical Instrumentation 2008;32(5):345-362
A new experimental software of an X-ray machine's console virtual operation system based on VB is introduced. This software can simulate the manual operation on the X-ray machine's console, and has the characteristics of easy operation, multi-function and good interactivity.
Computer Simulation
;
Software Design
;
Tomography, X-Ray Computed
;
instrumentation
;
methods
;
User-Computer Interface