1.Study on Clinical Application and Supervision of LC-MS in in Vitro Diagnosis Test.
Chaofu YE ; Lan ZHANG ; Yanqin KOU ; Yuhang WANG ; Xiaohe YANG
Chinese Journal of Medical Instrumentation 2023;47(6):690-694
From the perspective of technical evaluation, this study reviewed the current situation of application and clinical application of medical device products were detected by liquid chromatography-tandem mass spectrometry in the market in recent years. The regulatory requirements of these products in China, USA, EU and Japan were compared and analyzed, and the monitoring situation of adverse events after listing, the standards for reference and the domestic and foreign regulatory documents were combined, the clinical application and regulatory risks of the product were analyzed. The problems such as pre-treatment, system matching, adequacy of performance index requirements, inter-room consistency, reference interval and registration unit were discussed and suggestions for supervision were given, with a view to the field of product R&D and production, review and approval of supervision to provide technical reference.
Chromatography, Liquid/methods*
;
Tandem Mass Spectrometry/methods*
;
Reference Standards
;
Japan
2.Risk assessment of pesticide residues in domestic ginsengs.
Ying WANG ; Zhao WANG ; Zhi-Hua YUE ; Hong-Yu JIN ; Lei SUN ; Shuang-Cheng MA
China Journal of Chinese Materia Medica 2019;44(7):1327-1333
The study aims at taking risk assessment of pesticide residues in ginseng and high risk pesticides were picked up in order to provide a scientific basis for the establishment of maximum residue limits(MRLs) for pesticides in ginseng. Residues of 246 pesticides in 80 ginseng samples collected from different place were detected by GC-MS/MS and LC-MS/MS method. Acute and chronic intake risks were evaluated by using deterministic approach, and the matrix ranking developed by the Veterinary Residues Committee of the United Kingdom was referred to assess risk score of pesticides. The 25 kinds of pesticide residues were detected in ginseng samples, the detection rate of quintozene(PCNB) was 78%, which was the most frequently detectable pesticide. The chronic dietary intake risks of 25 pesticide residues expressed as %ADI were 0.00%-2.6%, and their acute dietary intake risks expressed as %ARfD were 0.00%-104.2%. Among them the acute dietary intake risks of PCNB was 104%,which was the highest. The 25 pesticides were divided into 3 groups by risk score, high risk group(4 pesticides), medium risk group(6 pesticides), and low risk group(15 pesticides). Hexachlorobenzene, phorate, PCNB and BHC were classified as high risk group. It is necessary and effective to establish the limit of residual organic chlorine in ginseng from Chinese Pharmacopoeia(2015 edition). MRLs for PCNB and hexachlorobenzene in ginseng were proposed to be revised based on the results of risk assessment.
Chromatography, Liquid
;
Drugs, Chinese Herbal
;
standards
;
Panax
;
chemistry
;
Pesticide Residues
;
analysis
;
Risk Assessment
;
Tandem Mass Spectrometry
3.Standardization of clinical application of mass spectrometry method for measurement of vitamin D in capillary blood of children: a multicenter study.
Luan Luan LI ; Xiao Nan LI ; Fei Yong JIA ; Mei Zhu CHI ; Zhi Hong WEN ; Fan YANG ; Yu Ning LI ; Li Jun HA ; Ying YANG ; Xiao Ling LONG ; Shuan Feng FANG ; Lu XIE ; Hui Feng ZHANG ; Xiaodan YU
Chinese Journal of Pediatrics 2022;60(12):1282-1287
Objective: To establish the norms and clinical application standards of mass spectrometry method to measure vitamin D in capillary blood. Methods: Following the "Province-City-Hospital" sampling procedure, a cross-sectional sample of 1 655 healthy children under 7 years of age were recruited from 12 provinces, autonomous regions, or municipalities in China from November 2020 to December 2021. Both venous and capillary blood samples from the same individual were collected, for which serum 25(OH)D levels were measured by high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) method. Pearson correlation analysis and linear regression analysis were used to detect the correlation and determine a correction algorithm. The agreement was analyzed using Bland-Altman plot and Kappa statistic. The sensitivity and specificity were evaluated using receiver operating characteristic (ROC) curve method. Results: Venous and capillary 25(OH)D levels of 1 655 healthy children under 7 years of age were 74.25 (59.50, 92.00) and 68.75 (54.44, 86.25) nmol/L, respectively, showed a significant difference(Z=22.14, P<0.001) as well as a highly significant correlation between venous and capillary 25(OH)D levels(r=0.95, P<0.001). Linear regression analysis was then performed to determine the correction algorithm: lg(corrected capillary 25(OH)D)=0.13+0.95×lg(capillary 25(OH)D)(R2=0.90,P<0.001). The deviation between venous and corrected capillary 25(OH)D levels was (0.50±17.50) nmol/L, a difference value that did not reach statistical significance (P>0.05). The cut-off values of capillary blood 25(OH)D values 30.00, 50.00, 75.00 nmol/L corresponding to venous blood 25(OH)D values were 26.59, 45.56, and 69.84 nmol/L, respectively. Good consistency was observed between venous and corrected capillary 25(OH)D levels in clinical diagnosis (Kappa value 0.68-0.81). Corrected capillary 25(OH)D showed a high clinically predictive value (area under curve 0.97-0.99,sensitivity 0.72-0.92,specificity 0.89-0.99). Conclusion: The standardized capillary HPLC-MS/MS method can be used to detect 25(OH)D levels in children clinically.
Child
;
Humans
;
Vitamin D
;
Cross-Sectional Studies
;
Tandem Mass Spectrometry
;
Vitamins
;
Reference Standards
4.Effects of stable isotope labeled internal standard on determination of ivabradine and N-demethylivabradine in human plasma.
Dong-qin LIU ; Jing-hua YU ; Yi-fan ZHANG ; Da-fang ZHONG ; Ling HE ; Xiao-yan CHEN
Acta Pharmaceutica Sinica 2015;50(3):348-354
This study aims to develop a liquid chromatography with tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of ivabradine and N-demethylivabradine in human plasma, and investigate effects of stable isotope labeled (SIL) internal standard (IS) on ivabradine. The analytes and IS were extracted from plasma by protein precipitation with acetonitrile, and chromatographied on a Capcell PAK C18 (100 mm x 4.6 mm, 5 μm) column using a mobile phase of methanol and 5 mmol x L(-1) ammonium acetate. Multiple reaction monitoring with electrospray ionization (ESI) was used in the positive mode for mass spectrometric detection. The effect of ivabradine isotope peak [M+H+3] + on IS and the effect of SIL IS purity on ivabradine were evaluated. An appropriate concentration of SIL IS was chosen to permit method selectivity and linearity of the assay over the required range. The standard curves were demonstrated to be linear in the range of 0.100 to 60.0 ng x mL(-1) for ivabradine, and 0.050 0 to 20.0 ng x mL(-1) for N-demethylivabradine. The intra and inter day precision and accuracy were within the acceptable limits for all concentrations. Besides, the interaction between IS and ivabradine did not impact the determination of analytes. This method was successfully applied to a pharmacokinetic study of hydrogen sulfate ivabradine sustained release tablets on Chinese healthy volunteers.
Benzazepines
;
blood
;
Chromatography, High Pressure Liquid
;
Delayed-Action Preparations
;
Humans
;
Isotope Labeling
;
standards
;
Reference Standards
;
Reproducibility of Results
;
Sensitivity and Specificity
;
Spectrometry, Mass, Electrospray Ionization
;
Tablets
;
Tandem Mass Spectrometry
5.Quantification of Human Plasma-Busulfan Concentration by Liquid Chromatography-Tandem Mass Spectrometry.
Soo Young MOON ; Min Kyoo LIM ; Susie HONG ; Yongbum JEON ; Minje HAN ; Sang Hoon SONG ; Kyoung Soo LIM ; Kyung Sang YU ; In Jin JANG ; Ji Won LEE ; Hyoung Jin KANG ; Junghan SONG
Annals of Laboratory Medicine 2014;34(1):7-14
BACKGROUND: Busulfan, an alkylating agent administered prior to hematopoietic stem cell transplantation, has a narrow therapeutic range and wide variability in metabolism. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for rapid and accurate quantification of plasma busulfan. METHODS: Busulfan was separated and detected using an LC system containing a C18 column equipped with MS/MS. The sample was eluted with a mobile phase gradient for a total run time of 10 min. Plasma busulfan concentration was quantified against a 6-point standard curve in a multiple reaction monitoring mode at mass-to-charge (m/z) 264.1 > 151.1. Precision, recovery, matrix effect, linearity, detection capability, carryover, and stability were evaluated. The range of plasma busulfan concentration was obtained by analyzing samples from 9 children receiving busulfan. RESULTS: The coefficients of variation of within-run and within-laboratory precision were all below 5%. Recoveries were all within the range of 100-105%. Linearity was verified from 0 to 5,000 ng/mL. Limit of detection and limit of quantification were 1.56 and 25 ng/mL, respectively. Carryover rate was within allowable limits. Plasma busulfan concentration was stable for 2 weeks at -20degrees C and -80degrees C, but decreased by 25% when the plasma was stored for 24 hr at room temperature, and by <5% in 24 hr at 4degrees C. The plasma busulfan concentrations were between 347 ng/mL and 5,076 ng/mL. CONCLUSIONS: Our method using LC-MS/MS enables highly accurate, reproducible, and rapid busulfan monitoring with minimal sample preparation. The method may also enable safe and proper dosage.
Busulfan/*blood/standards
;
Child
;
Child, Preschool
;
*Chromatography, High Pressure Liquid/standards
;
Hematopoietic Stem Cell Transplantation
;
Humans
;
Infant
;
Quality Control
;
Reference Standards
;
*Tandem Mass Spectrometry/standards
6.Analysis of Acid Sphingomyelinase Activity in Dried Blood Spots Using Tandem Mass Spectrometry.
Elisa LEGNINI ; Joe J ORSINI ; Adolf MUHL ; Britt JOHNSON ; Angela DAJNOKI ; Olaf A BODAMER
Annals of Laboratory Medicine 2012;32(5):319-323
BACKGROUND: Niemann Pick disease (NP) is a rare, lysosomal storage disorder due to deficiency of the intra-lysosomal enzyme acid sphingomyelinase (ASM) resulting in intracellular accumulation of sphingomyelin. We evaluated a tandem mass spectrometry (MS/MS) method to analyze ASM activity in dried blood spots (DBS) that may be suitable for laboratory diagnosis of NP including high throughput screening of at-risk populations and potentially for newborn screening. METHODS: ASM activity was measured in 3.2 mm punches from DBS. The eluate was incubated with the ASM substrate (N-Hexanoyl-D-erythro-sphingosylphosphorylcholine [C6-sphingomyelin (C29H59N2O6P)]) and an internal standard (N-butyroyl-D-erythro-sphingosine [C4-ceramide (C22H43NO3)]). ASM product and IS were analyzed using MS/MS in multiple reaction monitoring mode for transitions m/z 370.6>264.3 (ASM internal standard) and m/z 398.6>264.3 (ASM product). RESULTS: ASM activities were stable for up to 2 months at or below 4degrees C. Position of the punch in the DBS and/or hematocrit of the DBS had a limited effect on ASM activities. Both intra- and inter-assay variability were below 10%. There was no carry-over. The median ASM activity in 2,085 newborn infants was 9.5 micromol/h/L (mean 10.6) with a SD of 5.06 micromol/h/L. Six of 2,085 (0.3%) infants were found to have ASM activities below the cut-off of 2.5 micromol/h/L. ASM activities were below the cut-off level in all 10 previously diagnosed cases with NP (range: 0.16 to 2.08 micromol/h/L). CONCLUSIONS: This MS/MS method for the measurement of ASM activity in DBS is robust and suitable for laboratory diagnosis of NP.
*Dried Blood Spot Testing
;
Hematocrit
;
Humans
;
Infant, Newborn
;
Reference Standards
;
Sphingomyelin Phosphodiesterase/*analysis/standards
;
Sphingomyelins/metabolism
;
Substrate Specificity
;
*Tandem Mass Spectrometry/standards
7.Analysis of Acid Sphingomyelinase Activity in Dried Blood Spots Using Tandem Mass Spectrometry.
Elisa LEGNINI ; Joe J ORSINI ; Adolf MUHL ; Britt JOHNSON ; Angela DAJNOKI ; Olaf A BODAMER
Annals of Laboratory Medicine 2012;32(5):319-323
BACKGROUND: Niemann Pick disease (NP) is a rare, lysosomal storage disorder due to deficiency of the intra-lysosomal enzyme acid sphingomyelinase (ASM) resulting in intracellular accumulation of sphingomyelin. We evaluated a tandem mass spectrometry (MS/MS) method to analyze ASM activity in dried blood spots (DBS) that may be suitable for laboratory diagnosis of NP including high throughput screening of at-risk populations and potentially for newborn screening. METHODS: ASM activity was measured in 3.2 mm punches from DBS. The eluate was incubated with the ASM substrate (N-Hexanoyl-D-erythro-sphingosylphosphorylcholine [C6-sphingomyelin (C29H59N2O6P)]) and an internal standard (N-butyroyl-D-erythro-sphingosine [C4-ceramide (C22H43NO3)]). ASM product and IS were analyzed using MS/MS in multiple reaction monitoring mode for transitions m/z 370.6>264.3 (ASM internal standard) and m/z 398.6>264.3 (ASM product). RESULTS: ASM activities were stable for up to 2 months at or below 4degrees C. Position of the punch in the DBS and/or hematocrit of the DBS had a limited effect on ASM activities. Both intra- and inter-assay variability were below 10%. There was no carry-over. The median ASM activity in 2,085 newborn infants was 9.5 micromol/h/L (mean 10.6) with a SD of 5.06 micromol/h/L. Six of 2,085 (0.3%) infants were found to have ASM activities below the cut-off of 2.5 micromol/h/L. ASM activities were below the cut-off level in all 10 previously diagnosed cases with NP (range: 0.16 to 2.08 micromol/h/L). CONCLUSIONS: This MS/MS method for the measurement of ASM activity in DBS is robust and suitable for laboratory diagnosis of NP.
*Dried Blood Spot Testing
;
Hematocrit
;
Humans
;
Infant, Newborn
;
Reference Standards
;
Sphingomyelin Phosphodiesterase/*analysis/standards
;
Sphingomyelins/metabolism
;
Substrate Specificity
;
*Tandem Mass Spectrometry/standards
8.Newborn screening in Japan: restructuring for the new era.
Annals of the Academy of Medicine, Singapore 2008;37(12 Suppl):13-15
Nationwide neonatal mass screening for inherited metabolic diseases has started in Japan since 1977. At least 8000 children have probably been spared from handicaps resulting from such diseases over the past 30 years. Recently remarkable changes have been made to the evolving neonatal screening system. Declining birth rate and economic problems in Japan have demanded a more effective neonatal screening system. Development of new innovative screening methods and treatment tools, e.g. tandem mass spectrometry (MS/MS) technology and enzyme replacement therapy for mucopolysaccharidosis (MPS), have facilitated expansion of target diseases in neonatal screening. We have carried out pilot screening using MS/MS in 6 laboratories in Japan. The incidence of inherited metabolic diseases was found to be 1 in 9330 (65 cases out of 606,380 babies screened) during the period between 1997 and 2007. The incidence was lower than those of Europe or USA (about 1 in 4000 to 5000). The disease frequency between unscreened symptomatic cases and asymptomatic cases detected through MS/MS screening were also found to be different. In MS/MS screening, the most common organic acidemia was propionic acidemia, whereas in symptomatic cases, methylmalonic acidemia was the most common. Further study of ethnic diversity in severity of propionic academia is required. The outcomes of patients detected in the MS/MS screening were significantly favourable. The results showed the benefits of MS/ MS screening. The diagnostic support network for gas chromatography-mass spectrometry (GC/ MS) analysis and enzyme determination has also been developed. We have developed an automated system of GC/MS data processing and auto-diagnosis which allowed the GC/MS data processing to be extremely fast and simple. Enzyme evaluation for diagnostic support for screening, including a method using peripheral blood and high performance liquid chromatography (HPLC), and another method of in-vitro probe assay using cultured cells and MS/MS. Furthermore, re-location of screening laboratories for a more efficient screening network will be required such that at least 30,000 samples can be analysed in each laboratory.
Humans
;
Infant, Newborn
;
Japan
;
Metabolism, Inborn Errors
;
diagnosis
;
Neonatal Screening
;
methods
;
organization & administration
;
standards
;
Tandem Mass Spectrometry
9.Quality changes in Gastrodia Rhizoma of different origins and forms before and after sulfur fumigation.
Chuan-Zhi KANG ; Wan-Zhen YANG ; Li ZHOU ; Jing-Yi JIANG ; Chao-Geng LV ; Sheng WANG ; Tao ZHOU ; Ye YANG ; Lu-Qi HUANG ; Lan-Ping GUO
China Journal of Chinese Materia Medica 2018;43(2):254-260
As Gastrodiae Rhizoma (GR) is one of the herbs more seriously affected by sulfur fumigation, so its quality has been always of a great concern. In this paper, GR samples collected from eight main producing areas and in three forms were fumigated with sulfur and quantitatively and qualitatively analyzed based on UPLC-Q-TOF-MS/MS. The results showed that the contents of gastrodin, parishin, parishin B and parishin C were decreased, while the content of parishin E was increased after sulfur fumigation treatment. Besides, a new sulfur marker named p-hydroxybenzyl hydrogen sulfite was produced in sulfur-fumigated GR samples. As compared with producing origins, forms had a greater impact on the quality of GR, especially in Hongtianma and Wutianma. Besides, the contents of gastrodins and parishins in Hongtianma from Jilin were lowest as compared with those in other producing areas. This might be correlated with planting patterns and environmental factors. In conclusion, sulfur fumigation has a more obvious impact on the quality of GR than origins and forms, which is attributed to the generation of new sulfur fumigated markers.
Chromatography, High Pressure Liquid
;
Drugs, Chinese Herbal
;
standards
;
Fumigation
;
Gastrodia
;
chemistry
;
Quality Control
;
Rhizome
;
chemistry
;
Sulfur
;
Tandem Mass Spectrometry
10.Quantification of hepatotoxic pyrrolizidine alkaloid adonifoline in traditional Chinese medicine preparations containing Senecionis Scandentis Herba.
Fen XIONG ; Kai-Yuan JIANG ; Ai-Zhen XIONG ; Zheng-Cai JU ; Li YANG ; Zheng-Tao WANG
China Journal of Chinese Materia Medica 2020;45(1):92-97
Pyrrolizidine alkaloids(PAs) are a kind of natural toxins, which can cause severe hepatotoxicity, pulmonary toxicity, genotoxicity, neurotoxicity, embryotoxicity and even death. Therefore, international organizations and countries such as World Health Organization have paid great attention to herbal medicines and preparations containing PAs. PAs are widely distributed in Chinese herb medicines and contained in hundreds of traditional Chinese medicine preparations. The content of adonifoline, the main PAs in Senecionis Scandentis Herba, shall be less than 0.004% in herbal medicines as described in Chinese pharmacopeia. However, there is no guidance in preparations which contain Senecionis Scandentis Herba. In this study, 14 preparations were analyzed by an UPLC-MS method. Among them, 8 preparations were found to contain adonifoline much higher than the content limits of such countries as Germany, Netherlands and New Zealand. And the highest contents of adonifoline were found in Qianbai Biyan Tablets and Qianbai Biyan Capsules, which are officially recorded in Chinese Pharmacopeia. The contents of adonifoline varied in different batches of the same preparations. The highest content was 156.10 μg·g~(-1) Qianbai Biyan Tablets, whose daily intake of adonifoline was up to 1 030.26 μg according to the recommended dosage of the preparation. Our results showed the potential risk of these preparations, and the content limit of adonifoline shall be inspected Chinese medicine preparations containing Senecionis Scandentis Herba.
Chromatography, Liquid
;
Drugs, Chinese Herbal/standards*
;
Lactones/analysis*
;
Medicine, Chinese Traditional
;
Pyrrolizidine Alkaloids/analysis*
;
Senecio/chemistry*
;
Tandem Mass Spectrometry