1.Through the keyhole: Radiological management of malignant gastric outflow obstruction beyond the pylorus.
Robert Charles STOCKWELL ; Ji Hoon SHIN
Gastrointestinal Intervention 2016;5(2):111-115
This review article presents the radiological options for management of malignant gastric outflow obstruction distal to the pylorus. We place these options in context with surgical and endoscopic alternatives and recommend their use, particularly in those institutions where endoscopic alternatives may not be readily available.
Duodenal Obstruction
;
Pylorus*
;
Self Expandable Metallic Stents
;
Technology, Radiologic
2.Endoscopic Management of Anastomotic Strictures after Liver Transplantation.
Dong Wook LEE ; Hyeong Ho JO ; Juveria ABDULLAH ; Michel KAHALEH
Clinical Endoscopy 2016;49(5):457-461
Endoscopic treatment of biliary strictures involving plastic stent placement has been used widely. The use of self-expandable metal stents (SEMSs) has been described for anastomotic strictures following liver transplantation (LT). This review aimed to assess and compare the efficacy of plastic stents with SEMS in LT patients. Information was retrieved regarding technical success, stricture resolution, the number of endoscopic retrograde cholangiography procedures, follow-up, immediate, and late complications. Eight studies involving plastic stents had a stricture resolution rate of 84.5%, with the rates ranging from 63% to 100%. These rates are comparable with the stricture resolution rate of 75% determined from six studies that involved 236 patients who received metal stents and the rates ranged from 53% to 81%. The observed success rate for metal stents used to manage post-LT anastomotic biliary strictures was below the reported rate for multiple plastic stents. Hence, the currently available metal stents should not be offered for the management of post-LT anastomotic biliary strictures.
Cholangiography
;
Constriction, Pathologic*
;
Follow-Up Studies
;
Humans
;
Liver Transplantation*
;
Liver*
;
Plastics
;
Self Expandable Metallic Stents
;
Stents
3.Colonic cancer: The current role of stent insertion.
Gastrointestinal Intervention 2017;6(2):118-121
Acute colonic obstruction secondary to left-colonic malignancy remains a common emergency condition. Traditional management is emergency surgery and has high morbidity and mortality. Self expandable metallic stents (SEMS) promised to improve morbidity and mortality, stoma rates and hospital stay. SEMS use in the potentially curative setting, as a bridge to surgery, is associated with an improved stoma rate and morbidity, but has no mortality benefit. There are concerns about oncological safety with higher local recurrence rates, thus SEMS is not recommended in this setting unless the patient has increased surgical risk and would benefit from a period of recovery prior to surgery. SEMS has a definite role in the palliative setting, for both patients with incurable disease or those with a high surgical risk. SEMS is associated with improved morbidity, mortality, and stoma rates. The technique for SEMS insertion is now well established but it is still unclear whether covered or uncovered stents are better.
Colon*
;
Colonic Neoplasms*
;
Emergencies
;
Humans
;
Intestinal Obstruction
;
Length of Stay
;
Mortality
;
Recurrence
;
Self Expandable Metallic Stents
;
Stents*
4.Which is better for unresectable malignant hilar biliary obstruction: Side-by-side versus stent-in-stent?
Itaru NAITOH ; Tadahisa INOUE ; Kazuki HAYASHI
Gastrointestinal Intervention 2018;7(2):78-84
Biliary drainage is required for the management of unresectable malignant hilar biliary obstruction (UMHBO), and endoscopic transpapillary drainage is the first-line therapy because it is less invasive. Self-expandable metallic stents (SEMSs) are superior to plastic stents because they have longer stent patency and are more cost-effective. Endoscopic bilateral SEMS placement is technically challenging compared to unilateral placement. However, recent developments in devices and techniques have facilitated bilateral SEMS placement. There are two methods for bilateral hilar SEMS placement for UMHBO: side-by-side (SBS) and stent-in-stent (SIS). Sequential SBS was commonly conducted for bilateral hilar SEMS placement. In a new and thinner delivery system that was developed for SEM placement, two SEMSs could be simultaneously inserted and deployed through the working channel. This new bilateral stenting method enabled us to accomplish simultaneous SBS placement, which increased the success rate of SBS. Insertion of the guidewire and delivery of the second SEMS through the mesh of the first SEMS is challenging in SIS. Newly designed or modified SEMSs that are suitable for SIS have been developed to overcome this challenge, and these SEMSs have facilitated SIS. Uncovered SEMS has been commonly used for hilar SEMS placement, but covered SEMS (CSEMS) is another option for hilar SEMS placement, because CSEMS prevents tumor ingrowth and allows for removal of the stent for re-intervention. Therefore, CSEMS can be used for bilateral SEMS placement in SBS. There are many methods and kinds of SEMS available for bilateral SEMS placement. However, due to lack of evidence, there is no consensus on whether SBS or SIS is optimal for bilateral hilar SEMS placement. In this review, we compared various outcomes between SBS and SIS from previous studies, to clarify which method is better for bilateral SEMS placement for UMHBO.
Cholangiopancreatography, Endoscopic Retrograde
;
Cholestasis
;
Consensus
;
Drainage
;
Klatskin Tumor
;
Methods
;
Plastics
;
Self Expandable Metallic Stents
;
Stents
5.Prospective Multicenter Study of the Challenges Inherent in Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction.
Min Jae YANG ; Jin Hong KIM ; Jae Chul HWANG ; Byung Moo YOO ; Sang Hyub LEE ; Ji Kon RYU ; Yong Tae KIM ; Sang Myung WOO ; Woo Jin LEE ; Seok JEONG ; Don Haeng LEE
Gut and Liver 2018;12(6):722-727
BACKGROUND/AIMS: Although endoscopic bilateral stent-in-stent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic re-intervention. This study aimed to evaluate the technical accessibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. METHODS: Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. RESULTS: Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases of technical success. Stent occlusion occurred in 63.2% of the patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months postoperatively, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. CONCLUSIONS: Large cell-type stents for endoscopic bilateral stent-in-stent placement had acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.
Cholangiopancreatography, Endoscopic Retrograde
;
Cholestasis, Intrahepatic
;
Drainage
;
Humans
;
Klatskin Tumor
;
Prospective Studies*
;
Self Expandable Metallic Stents
;
Stents*
6.Covered Self-expandable Metallic Stent Insertion as a Rescue Procedure for Postoperative Leakage after Primary Repair of Perforated Duodenal Ulcer.
Young Jin YOO ; Yong Kang LEE ; Joong Ho LEE ; Hyung Soon LEE
The Korean Journal of Gastroenterology 2018;72(5):262-266
Surgery has been the standard treatment for perforated duodenal ulcers, with mostly good results. However, the resolution of postoperative leakage after primary repair of perforated duodenal ulcer remains challenging. There are several choices for re-operation required in persistent leakage from perforated duodenal ulcers. However, many of these choices are complicated surgical procedures requiring prolonged general anesthesia that may increase the chances of morbidity and mortality. Several recent reports have demonstrated postoperative leakage after primary repair of a perforated duodenal ulcer treated with endoscopic insertion using a covered self-expandable metallic stent, with good clinical results. We report a case with postoperative leakage after primary repair of a perforated duodenal ulcer treated using a covered self-expandable metallic stent.
Anesthesia, General
;
Duodenal Ulcer*
;
Mortality
;
Peptic Ulcer Perforation
;
Self Expandable Metallic Stents
;
Stents*
7.Comprehensive management of cholangiocarcinoma: Part II. Treatment.
Charilaos PAPAFRAGKAKIS ; Jeffrey H LEE
Gastrointestinal Intervention 2017;6(2):94-104
Cholangioarcinoma is a rare but dreadful malignancy which poses much difficulties in the management. If detected early with only localized disease, curative resection is possible. However, most patients present in the late stages of the disease, which are managed with endoscopic biliary drainage and/or chemoradiation. Liver transplantation offers a possibility for cure in the distal and the perihilar tumors for selected candidates. Local treatments, such as hepatic artery-based therapies, brachytherapy, and photodynamic therapy, may offer some benefit in cases of the advanced disease. In this review, we will assess the role of preoperative biliary drainage, how best to drain biliary obstruction, and the intricate details of various treatments that are currently available.
Brachytherapy
;
Cholangiocarcinoma*
;
Cholestasis
;
Drainage
;
Endosonography
;
Humans
;
Liver Transplantation
;
Photochemotherapy
;
Self Expandable Metallic Stents
8.Safety performance of self-expandable NiTi alloy stent.
Zhiguo LI ; Wengang YAN ; Haiquan FENG
Journal of Biomedical Engineering 2020;37(2):334-339
In order to evaluate the safety performance of self-expandable NiTi alloy stents systematically, the dynamic safety factor drawn up by International Organization for Standardization, was used to quantitatively reflect the safety performance of stents. Based on the constitutive model of super-elastic memory alloy material in Abaqus and uniaxial tensile test data of NiTi alloy tube, finite element method and experiments on accelerated fatigue life were carried out to simulate the self-expansion process and the shape change process under the action of high and low blood pressure for three -type stents of 8×30 mm, 10×30 mm, 12×30 mm. By analyzing the changes of stress and strain of self-expanding NiTi alloy stent, the maximum stress and strain, stress concentration position, fatigue strength and possible failure modes were studied, thus the dynamic safety factor of stent was calculated. The results showed that the maximum stress and plastic strain of the stent increased with the increase of grip pressure, but the maximum stress and strain distribution area of the stent had no significant change, which were all concentrated in the inner arc between the support and the connector. The dynamic safety factors of the three stents were 1.31, 1.23 and 1.14, respectively, which indicates that the three stents have better safety and reliability, and can meet the fatigue life requirements of more than 10 years, and safety performance of the three stents decreases with the increase of stent's original diameter.
Alloys
;
Finite Element Analysis
;
Nickel
;
Reproducibility of Results
;
Self Expandable Metallic Stents
;
Stress, Mechanical
;
Titanium
9.Endoscopic management of postsurgical leaks.
Gastrointestinal Intervention 2016;5(1):6-14
Postsurgical leaks are a major complication with significant mobidity and mortality. Conventional conservative and surgical approaches are highly morbid with limited success. Over the last decade several endoscopic techniques have proved effective with a favorable safety profile. Nevertheless, most data still come from retrospective series, and many studies included heterogenous patient groups pooling complex surgical leaks with minor endoscopic perforations. This review focuses on the endoscopic management of the more difficult postsurgical leaks. Stents and over-the-scope clips are currently the key endoscopic techniques for leak closure, but emerging techniques such as vacuum sponge therapy and endoscopic internal drainage have proved to be at least as effective. The current trend is to use these different techniques interchangeably or simultaneously rather than assuming a single standardized approach.
Anastomotic Leak
;
Drainage
;
Esophageal Fistula
;
Gastric Fistula
;
Humans
;
Mortality
;
Porifera
;
Retrospective Studies
;
Self Expandable Metallic Stents
;
Stents
;
Vacuum
10.A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet Obstruction.
Naminatsu TAKAHARA ; Hiroyuki ISAYAMA ; Yousuke NAKAI ; Shuntaro YOSHIDA ; Tomotaka SAITO ; Suguru MIZUNO ; Hiroshi YAGIOKA ; Hirofumi KOGURE ; Osamu TOGAWA ; Saburo MATSUBARA ; Yukiko ITO ; Natsuyo YAMAMOTO ; Minoru TADA ; Kazuhiko KOIKE
Gut and Liver 2017;11(4):481-488
BACKGROUND/AIMS: Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. METHODS: We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. RESULTS: The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. CONCLUSIONS: A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.
Gastric Outlet Obstruction*
;
Humans
;
Palliative Care
;
Pancreatitis
;
Retrospective Studies
;
Self Expandable Metallic Stents
;
Stents*
;
Tertiary Care Centers