1.Bilateral frontalis sling for surgical correction of unilateral and bilateral severe congenital ptosis with poor levator function
Philippine Journal of Ophthalmology 2023;48(2):67-73
Objective:
This study evaluated the functional and cosmetic outcomes after bilateral frontalis sling repair using either expanded polytetrafluoroethylene (ePTFE) or silicone rod for unilateral or bilateral severe congenital ptosis with poor levator function.
Methods:
This was a non-comparative, interventional case series involving 30 patients with unilateral or bilateral severe congenital ptosis who underwent bilateral frontalis sling repair from February 2012 to November 2018. Medical records including pre- and postoperative photographs were reviewed. The functional and cosmetic outcomes were assessed.
Results:
There were 15 patients with severe congenital ptosis who underwent ePTFE surgery and 15 patients who had silicone rod surgery. Baseline levator function measured was less than 5 mm in all patients. The mean follow-up duration after surgery was 15.6+6.9 months. Satisfactory eyelid contour was observed in all patients (100%). Postoperatively, all had good to excellent primary eyelid position and effective frontalis action on eyelid elevation. Complications included exposure of the silicone sling material after trauma at the brow area (n=1) and recurrence of ptosis (n=2).
Conclusion
Bilateral frontalis suspension in patients with severe congenital ptosis, whether bilateral or unilateral, resulted in excellent functional and cosmetic outcomes using ePTFE or silicone rod.
Polytetrafluoroethylene
2.The Effect of Negative electric field using charged PTFE membrane on Bone Healing of Rabbit Long Bone.
Yong Su KWON ; Jin Woo PARK ; Jae Mok LEE ; Jo Young SUH
The Journal of the Korean Academy of Periodontology 2004;34(3):551-562
No abstract available.
Membranes*
;
Polytetrafluoroethylene*
3.Chemical compatibility of interim material and bonding agent on shear bond strength.
Journal of Dental Rehabilitation and Applied Science 2016;32(4):293-300
PURPOSE: The purpose of this study is finding proper bonding agents to be used when adding bis-acryl composite provisional materials. MATERIALS AND METHODS: Three bonding agents with different chemical compositions were included in this study. Forty disk shaped specimens of bis-acryl composite provisional material were prepared and divided into 4 groups according to the bonding agents. Control group didn't have bonding agent. Through the Teflon mould with 4.0 mm diameter hole with 4.0 mm thickness the same bis-acryl composite provisional material was added on the disks after the surface of each specimen was treated with designated bonding agent according to the manufacturer's instructions. Shear bond test was performed and the fractured surfaces were inspected with a microscope. One-way analysis of variance was conducted and the result was further analysed with Turkey post hoc test at the significance level of 0.05. RESULTS: The highest strength was acquired from the specimens bonded with chemical cure system and it was statistically significant (P < 0.05). This group showed 100% cohesive failures. The lowest bonding strength was recorded from the specimens used conventional light cure bonding agent, and this group's result was similar with the control group. The group used a light cure bonding agent claiming improved compatibility revealed significantly higher bond strength to the traditional light cure bonding agent group in a statistically significant way (P = 0.043). CONCLUSION: According to the bonding agent used the shear bond strength was significantly affected. Therefore the choice of proper bonding agent is important when hiring a bonding agent to add bis-acryl composite provisional materials.
Polytetrafluoroethylene
;
Turkey
4.Reconstruction of chronic ACL insufficiency using gore-tex prosthetic ligament substitute.
Yeub KIM ; Ki Soo KIM ; Seung Tack KIM ; Seung Hee KO ; Jun Young SONG ; Jong Kun CHUNG
The Journal of the Korean Orthopaedic Association 1992;27(5):1328-1336
No abstract available.
Ligaments*
;
Polytetrafluoroethylene*
5.The Effect of Polytetrafluoroethylene on Delayed Adjustable Strabismus Surgery.
Jeong Min HWANG ; Bong Leen CHANG
Journal of the Korean Ophthalmological Society 1996;37(3):517-523
Delayed reattachment of the muscle to the sclera may be desirable to correct the deviation of eye developed after the surgery. Polytetrafluoroethylene(PTFE) was placed around the cut end of the muscle as a physical barrier between the free muscle end and the sclera in 16 rabbits in order to prevent the postoperative adhesions. PTFE was effective in delaying the adjustment for up to 4 weeks after surgery in 4 out of 10 eyes. After removal of PTFE, adjustment was possible up to 12 weeks in 24 out of 25 eyes because there was no adhesion between the muscle and PTFE. In conclusion, PTFE may be clinically helpful for delaying the timing of adjustment.
Polytetrafluoroethylene*
;
Rabbits
;
Sclera
;
Strabismus*
6.LiF TLD in TLD Holder for In Vivo Dosimetry.
Sookil KIM ; John J K LOH ; Byungnim MIN
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2001;19(3):293-299
PURPOSE: LiF TLD has a problem to be used in vivo dosimetry because of the toxic property of LiF. The aim of this study is to develop new dosimeter with LiF TLD to be used in vivo dosimetry. MATERIALS AND METHODS: We designed and manufactured the teflon box(here after TLD holder) to put TLD in. The external size of TLD holder is 4x4x1 mm3. To estimate the effect of TLD holder on TLD response for radiation, the linearity of TLD response to nominal dose were measured for TLD in TLD holder. Measurement were performed in the 10 MV x-ray beam with LiF TLD using a solid water phantom at SSD of 100 cm. Percent Depth Dose (PDD) and Tissue-Maximum Ratio (TMR) with varying phantom thickness on TLD were measured to find the effect of TLD holder on the dose coefficient used for dose calculation in radiation therapy. RESULTS: The linearity of response of TLD in TLD holder to the nominal dose was improved than TLD only used as dosimeter. And in various measurement conditions, it makes a marginnal difference between TLD in TLD holder and TLD only in their responses. CONCLUSION: It was proven that the TLD in TLD holder as a new dosimetry could be used in vivo dosimetry.
Polytetrafluoroethylene
;
Silver Sulfadiazine
;
Water
7.The Combined Effect of Physical Barriers and 5-Fluorouracil on Delayed Adjustable Strabismus Surgery.
Jeong Min HWANG ; bong Leen CHANG
Journal of the Korean Ophthalmological Society 1999;40(1):211-218
In order to prevent the formation of postoperative adhesions and delay the time of adjustment, the authors tried 5-fluorouracil and physical barriers of polytetrafluoroethylene, Interceed, Viscoat in rabbits. Fluorouracil delayed the adjustment for up to one week after surgery in three out of four eyes. Combined use of Interceed and 5-fluorouracil of addition of Viscoat could delay the adjustment for up to two weeks after surgery I one out of four eyes. Combined use of pophtetrafluoroethylene and 5-fluorouracil of addition of Viscoat could delay the adjustment for up to four weeks after surgery in four out of five eyes. In conclusion, combined use of polytetrafluoroethylene, 5-fluorouracil and Viscoat could be more helpful for delayine adjustment in rabbits.
Fluorouracil*
;
Polytetrafluoroethylene
;
Rabbits
;
Strabismus*
8.Nasal augmentation using goretex
Jin young CHOI ; Chul Gi MIN ; Hoon MYOUNG ; Soon Jung HWANG ; Byoung Moo SEO ; Jong Ho LEE ; Pill Hoon CHOUNG ; Myung Jin KIM
Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons 2003;25(4):331-336
polytetrafluoroethylene) which has widely used in vascular surgery and abdominal surgery can be used for facial soft tissue augmentation. The author presents 2 cases of nasal augmentaion using goretex with literature review.]]>
Allografts
;
Polytetrafluoroethylene
;
Silicones
9.Changes in Implant Thickness after Rhinoplasty Using Surgiform
Sun Jae LEE ; Bong Il RHO ; Seung Min NAM ; Jun Beom LEE ; Eun Soo PARK
Archives of Aesthetic Plastic Surgery 2018;24(1):1-5
BACKGROUND: Gore-Tex implants started out as a product with the distinct advantage of producing a natural nose shape, but using Gore-Tex, it is difficult to predict the height of the nose after rhinoplasty because Gore-Tex contracts over time, making the nose shrink. However, Surgiform, a new form of expanded polytetrafluoroethylene (ePTFE) implant, enables prediction of the height of the nose after rhinoplasty because the implant does not change in thickness even after many years. Thus, we investigated whether changes in implant thickness occurred after rhinoplasty using Surgiform implants. METHODS: This study enrolled 12 patients who had Surgiform nasal implants removed for any reason after receiving rhinoplasty in 2007 or later. After the Surgiform implants were removed, we measured the thickness of the central part of the implants using calipers. RESULTS: At the time of the initial operation, the mean implant thickness was 4.48±0.30 mm at the supra-tip. At the time of implant removal, the mean thickness was 4.32±0.29 mm. The implants maintained 96.5% of their initial thickness. There was a negligible reduction in the Surgiform implants' thickness over time. CONCLUSIONS: Surgiform implants maintained their shape after rhinoplasty, making it possible to predict the height of the nose. Thus, Surgiform is more useful for nasal implants than other ePTFE implants.
Humans
;
Nose
;
Polytetrafluoroethylene
;
Rhinoplasty
10.Effect of curing modes on micro-hardness of dual-cure resin cements.
Ki Deok LEE ; Se Hee PARK ; Jin Woo KIM ; Kyung Mo CHO
Journal of Korean Academy of Conservative Dentistry 2011;36(2):132-138
OBJECTIVES: The purpose of this study was to evaluate curing degree of three dual-cure resin cements with the elapsed time in self-cure and dual-cure mode by means of the repeated measure of micro-hardness. MATERIALS AND METHODS: Two dual-cure self-adhesive resin cements studied were Maxcem Elite (Kerr), Rely-X Unicem (3M ESPE) and one conventional dual-cure resin cement was Rely-X ARC resin cement (3M ESPE). Twenty specimens for each cements were made in Teflon mould and divided equally by self-cure and dual-cure mode and left in dark, 36degrees C, 100% relative humidity conditional-micro-hardness was measured at 10 min, 30 min, 1 hr, 3 hr, 6 hr, 12 hr and 24 hr after baseline. The results of micro-hardness value were statistically analyzed using independent samples t-test and one-way ANOVA with multiple comparisons using Scheffe's test. RESULTS: The micro-hardness values were increased with time in every test groups. Dual-cure mode obtained higher micro-hardness value than self-cure mode except after one hour of Maxcem. Self-cured Rely-X Unicem showed lowest value and dual-cured Rely-X Unicem showed highest value in every measuring time. CONCLUSIONS: Sufficient light curing to dual-cure resin cements should provided for achieve maximum curing.
Humidity
;
Light
;
Polytetrafluoroethylene
;
Resin Cements