1.The effect of Er:YAG laser irradiation on the surface microstructure and roughness of TiO2 implant.
Jang Hyuk AN ; Young Hyuk KWON ; Joon Bong PARK ; Yeek HERR ; Jong Hyuk CHUNG
The Journal of the Korean Academy of Periodontology 2008;38(1):67-74
PURPOSE: The aim of this study was to evaluate the effect of Er:YAG laser on microstructure and roughness of TiO2 blasting implant surface. MATERIALS AND METHODS: Ten TiO2 blasting implant were used in this experiment. One implant was control group, and nine TiO2 blasting implant surfaces were irradiated with Er:YAG laser under 100 mJ/pulse, 140 mJ/pulse, and 180 mJ/pulse condition for 1 min, 1.5 min, and 2 min respectively. Optical interferometer and scanning electron microscopy was utilized to measure roughness and microstructure of specimens. RESULTS: The surface roughness was decreased after Er:YAG laser irradiation in all groups, but there was no significant difference. 100 mJ/pulse and 140 mJ/pulse group did not alter the TiO2 blasting implant surface in SEM study while 180 mJ/pulse group altered the TiO2 blasting implant surface. Implant surfaces showed melting, microfracture and smooth surface in 180 mJ/pulse group. CONCLUSION: Detoxification of implant surface using Er:YAG laser must be irradiated with proper energy output and irradiation time to prevent implant surface alteration.
Freezing
;
Microscopy, Electron, Scanning
2.Morphology of the Terminal Segments of Megaselia scalaris (Loew) (Diptera: Phoridae) using Scanning Electron Microscopy
Raja Muhammad Zuha ; Atiah Ayunni Abdul Ghani
Malaysian Journal of Health Sciences 2016;14(2):141-143
Megaselia scalaris (Loew) (Diptera: Phoridae) is a cosmopolitan scuttle fly of medical and forensic importance. This species is generally small, humpbacked and is a prominent decomposer of corpses indoors. Taxonomically, adult sexes can be distinguished based on the characteristics of the terminal segments of the abdomen. In this report, the terminalia of adult male and female M. scalaris were examined using scanning electron microscope (SEM). The terminal segment of an adult female is less complex compared to male, consisting of an ovipositor and cerci. In male, the hypopygium consists of epandrium, hypandrium, anal tube and penis complex. A pair of long and feathered setae was attached to the tip of the anal tube and tapered. The application of SEM to identify this species isuseful and can be expanded to other species in this fly group.
Microscopy, Electron, Scanning
3.Comparison of mechanical properties of a new fiber reinforced composite and bulk filling composites.
Hazem ABOUELLEIL ; Nelly PRADELLE ; Cyril VILLAT ; Nina ATTIK ; Pierre COLON ; Brigitte GROSGOGEAT
Restorative Dentistry & Endodontics 2015;40(4):262-270
OBJECTIVES: The aim of this study was to evaluate the mechanical and physical properties of a newly developed fiber reinforced dental composite. MATERIALS AND METHODS: Fiber reinforced composite EverX Posterior (EXP, GC EUROPE), and other commercially available bulk fill composites, including Filtek Bulk Fill (FB, 3M ESPE), SonicFill (SF, Kerr Corp.), SureFil (SDR, Dentsply), Venus Bulk Fill (VB, HerausKultzer), Tetric evoceram bulk fill (TECB, Ivoclar Vivadent), and Xtra Base (XB, Voco) were characterized. Composite samples light-cured with a LED device were evaluated in terms of flexural strength, flexural modulus (ISO 4049, n = 6), fracture toughness (n = 6), and Vickers hardness (0, 2, and 4 mm in depth at 24 hr, n = 5). The EXP samples and the fracture surface were observed under a scanning electron microscopy. Data were statistically analyzed using one-way ANOVA and unpaired t-test. RESULTS: EXP, FB, and VB had significantly higher fracture toughness value compared to all the other bulk composite types. SF, EXP, and XB were not statistically different, and had significantly higher flexural strength values compared to other tested composite materials. EXP had the highest flexural modulus, VB had the lowest values. Vickers hardness values revealed SF, EXP, TECB, and XB were not statistically different, and had significantly higher values compared to other tested composite materials. SEM observations show well dispersed fibers working as a reinforcing phase. CONCLUSIONS: The addition of fibers to methacrylate-based matrix results in composites with either comparable or superior mechanical properties compared to the other bulk fill materials tested.
Hardness
;
Microscopy, Electron, Scanning
;
Venus
4.A Study on the Retentive Force of Stud Attachments for Implant Overdenture.
Eun Ju SONG ; Eun Bin BAE ; Jae Won CHOI ; Ji Hyeon BAE ; Ji Young KIM ; So Hyoun LEE
Journal of Dental Hygiene Science 2016;16(1):93-100
The purpose of this study was to compare the changes of retentive force in different stud attachment systems for implant retained overdenture. Two commercially available attachments with different retentive forces were investigated: Kerator (pink, blue, red) and O-ring (orange, red). Two implant fixtures were vertically embedded in base mountings. Five pairs of each attachment were evaluated. A universal testing machine was used to evaluate the retentive force of two attachments during wear simulation. Surface characteristics of each attachment system were evaluated with scanning electron microscopy. Five pairs of each attachment were evaluated. Kerator pink showed the highest initial retention. After 2,500 cycles of wear-simulation, Kerator pink noted the largest decrease in retention. According to results of surface analysis, Worn surfaces were obtained in matrices and patrices. Heavy wears were observed in matrices. After 2 year-wear simulation, most attachments exhibited retention loss. Attachments using different kind of material exhibited dissimilar surface alterations.
Denture, Overlay*
;
Microscopy, Electron, Scanning
5.Scanning Electron Microscopy (SEM) investigation of Polystyrene damage due to colonization by locally isolated Xylaria sp.
Janine Erica D. ABECIA ; Mary Bernadette V. EGLOSO ; Mary Ann TAVANLAR ; Anna Theresa A. SANTIAGO
Philippine Journal of Health Research and Development 2019;23(1):64-70
BACKGROUND AND OBJECTIVES: Colonization of microorganisms on pollutants is the first indication of the potential ability of microbes to utilize plastic pollutants as a carbon source by sequential biodegradation into usable form for sustenance. The Philippines is considered the third highest country contributing to global mismanaged plastic waste. To locally manage and find a natural and innovative solution to this worldwide concern, this study aimed to evaluate the capacity of Xylaria sp. SDM (sterile dark mycelia) wild type, which was previously reported to colonize polyethylene plastic and mutant strains to colonize polystyrene, a plastic pollutant widely produced in the world. Assessment of the ability of local Xylaria sp. strains to grow, penetrate, and damage the surface and inner structures of polystyrene was investigated using scanning electron microscopy (SEM).
METHODOLOGY: Xylaria sp. strains were cultured in a pH 5.0 mineral medium with 0.5% glucose as carbon source and polystyrene as a co-carbon source, and stored at 25?C for 50 days. At the end of the incubation period, due to irremovable fungal strains on the surface of the polystyrene strips, samples of polystyrene from each strain were subjected to SEM.
RESULTS: On the 20th day of incubation, the presence of mucilaginous sheaths and fungal growth was observed on the surface of treated polystyrene strips. At the end of the 50-day incubation period, scanning electron microscopy (SEM) confirmed fungal growth and colonization, through the presence of mycelial mats and hyphae, of the wild type and mutant strains on the surface and inner structures of polystyrene except the control. Moreover, physical surface damage in the form of holes, cracks, and crevices on polystyrene demonstrated the active burrowing action of Xylaria sp. strains further supporting the potential of this fungus to damage polystyrene plastic.
CONCLUSION: Whereas fungal growth on a polymer surface is necessary but not sufficient to conclude the process of carbon assimilation as the final biodegradation step, the initial colonization of Xylaria sp. strains on polystyrene supports its ability to establish itself and physically damage the pollutant. Hence, this study extended the existing knowledge on the colonizing ability of Xylaria sp. on plastic making it a potential candidate organism to biodegrade plastic waste, which is one of the topmost environmental waste hazards in the world today.
Polystyrenes ; Plastics ; Microscopy, Electron, Scanning
6.The genus Hypoxylon, Wood Decay Fungi - II. Teleomorph of Annulata Section.
Mycobiology 2000;28(1):1-4
The section of Annulata under genus Hypoxylon is a member of the Xylariaceae which has ascomata with ostioles papillate ill a flattened disc. The isolates of Hypoxylon collected from the Tropic to the Temperate are compared with similar taxa and described. These isolations under Annulata section are illustrated with a light microscopy and a scanning electron microscopy. Hypoxylon archeri is newly recorded from Korea. A key to the species is also included.
Fungi*
;
Korea
;
Microscopy
;
Microscopy, Electron, Scanning
;
Wood*
7.Comparison of changes in retentive force of three stud attachments for implant overdentures.
Su Min KIM ; Jae Won CHOI ; Young Chan JEON ; Chang Mo JEONG ; Mi Jung YUN ; So Hyoun LEE ; Jung Bo HUH
The Journal of Advanced Prosthodontics 2015;7(4):303-311
PURPOSE: The aim of this study was to compare the changes in retentive force of stud attachments for implant overdentures by in vitro 2-year-wear simulation. MATERIALS AND METHODS: Three commercially available attachment systems were investigated: Kerator blue, O-ring red, and EZ lock. Two implant fixtures were embedded in parallel in each custom base mounting. Five pairs of each attachment system were tested. A universal testing machine was used to measure the retentive force during 2500 insertion and removal cycles. Surface changes on the components were evaluated by scanning electron microscopy (SEM). A Kruskal-Wallis test, followed by Pairwise comparison, was used to compare the retentive force between the groups, and to determine groups that were significantly different (alpha<.05). RESULTS: A comparison of the initial retentive force revealed the highest value for Kerator, followed by the O-ring and EZ lock attachments. However, no significant difference was detected between Kerator and O-ring (P>.05). After 2500 insertion and removal cycles, the highest retention loss was recorded for O-ring, and no significant difference between Kerator and EZ lock (P>.05). Also, Kerator showed the highest retentive force, followed by EZ lock and O-ring, after 2500 cycles (P<.05). Based on SEM analysis, the polymeric components in O-ring and Kerator were observed to exhibit surface wear and deformation. CONCLUSION: After 2500 insertion and removal cycles, all attachments exhibited significant loss in retention. Mechanism of retention loss can only be partially explained by surface changes.
Denture, Overlay*
;
Microscopy, Electron, Scanning
;
Polymers
8.Repair bond strengths of non-aged and aged resin nanoceramics.
Meryem Gülce SUBAŞI ; Gülce ALP
The Journal of Advanced Prosthodontics 2017;9(5):364-370
PURPOSE: To explore the influence of different surface conditionings on surface changes and the influence of surface treatments and aging on the bond strengths of composites to non-aged and aged resin nanoceramics. MATERIALS AND METHODS: Rectangular-shaped non-aged and aged (5000 thermocycles) resin nanoceramic specimens (Lava Ultimate) (n=63, each) were divided into 3 groups according to surface treatments (untreated, air abrasion, or silica coating) (n=21). The surface roughness was measured and scanning electron microscopy was used to examine one specimen from each group. Afterwards, the specimens were repaired with a composite resin (Filtek Z550) and half were sent for aging (5000 thermocycles, n=10, each). Shear bond strengths and failure types were evaluated. Roughness and bond strength were investigated by two- and three-way analysis of variance, respectively. The correlation between the roughness and bond strength was investigated by Pearson's correlation test. RESULTS: Surface-treated samples had higher roughness compared with the untreated specimens (P=.000). For the non-aged resin nanoceramic groups, aging was a significant factor for bond strength; for the aged resin nanoceramic groups, surface treatment and aging were significant factors. The failures were mostly adhesive after thermal cycling, except in the non-aged untreated group and the aged air-abraded group, which had mostly mixed failures. Roughness and bond strength were positively correlated (P=.003). CONCLUSION: Surface treatment is not required for the repair of non-aged resin nanoceramic; for the repair of aged resin nanoceramic restorations, air abrasion is recommended.
Adhesives
;
Aging
;
Microscopy, Electron, Scanning
;
Silicon Dioxide
9.Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study.
Fariborz AMINI ; Vahid RAKHSHAN ; Maryam POUSTI ; Hajir RAHIMI ; Mahsa SHARIATI ; Bahareh AGHAMOHAMADI
The Korean Journal of Orthodontics 2012;42(3):129-137
OBJECTIVE: The purpose of this study was to evaluate the surface roughness (SR) of 2 types of orthodontic archwires made by 4 different manufacturers. METHODS: This in vitro experimental study was conducted on 35 specimens of 7 different orthodontic archwires, namely, 1 nickel-titanium (NiTi) archwire each from the manufacturers American Orthodontics, OrthoTechnology, All-Star Orthodontics, and Smart Technology, and 1 stainless steel (SS) archwire each from the manufacturers American Orthodontics, OrthoTechnology, and All-Star Orthodontics. After analyzing the composition of each wire by energy-dispersive X-ray analysis, the SR of each wire was determined by scanning electron microscopy (SEM) and surface profilometry. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (alpha < 0.05). RESULTS: The average SR of NiTi wires manufactured by Smart Technology, American Orthodontics, OrthoTechnology, and All-Star Orthodontics were 1,289 +/- 915 Adegrees, 1,378 +/- 372 Adegrees, 2,444 +/- 369 Adegrees, and 5,242 +/- 2,832 Adegrees, respectively. The average SR of SS wires manufactured by All-Star Orthodontics, OrthoTechnology, and American Orthodontics were 710 +/- 210 Adegrees, 1,831 +/- 1,156 Adegrees, and 4,018 +/- 2,214 Adegrees, respectively. Similar to the results of profilometry, the SEM images showed more defects and cracks on the SS wire made by American Orthodontics and the NiTi wire made by All-Star Orthodontics than others. CONCLUSIONS: The NiTi wire manufactured by All-Star Orthodontics and the SS wire made by American Orthodontics were the roughest wires.
Microscopy, Electron, Scanning
;
Orthodontics
;
Stainless Steel
10.A qualitative analysis of bonding between electroformed surface and veneering ceramics.
The Journal of Korean Academy of Prosthodontics 2000;38(3):328-335
STATEMENT of THE PROBLEM: Recently an innovative method of fabricating indirect restorations by gold electroforming has been developed. But the bond quality and strength of the gold coping to the porcelain is uncertain. PURPOSE of STUDY: The purpose of this study is to analyze and evaluate the electroformed gold surface for mechanical bonding between the gold and the ceramic veneering. METHODS and MATERIAL: Electroformed disks were made using electroforming technique. And the surface of the electroformed coping was analyzed after sandblasting, heat-treatment, bonding agent application, opaque porcelain firing with scanning electron microscopy and energy dispersive x-ray analysis. Results. In the analysis with SEM, Sandblasting made the sharp edges and undercuts on the electroformed surface, and after bonding agent application, net-like structure were created on the electroformed surface. In the energy dispersive x-ray analysis it is confirmed that electroformed surface contains some impurities. CONCLUSION: With the use of sandblasting and bonding agent, electroformed surface seems to be enough to bond with veneering porcelain.
Ceramics*
;
Dental Porcelain
;
Fires
;
Microscopy, Electron, Scanning