1.An electrochemical study on the corrosion resistance of the various implant metals.
The Journal of Korean Academy of Prosthodontics 1993;31(3):423-446
No abstract available.
Corrosion*
;
Metals*
2.Metals and Ceramics for Medical Applications.
Journal of the Korean Medical Association 1997;40(4):459-470
3.Transepidermal Elimination of Gold Metals after Face-Lifting Acupuncture.
Dong In KEUM ; Hana BAK ; Sung Ku AHN
Annals of Dermatology 2016;28(4):501-502
No abstract available.
Acupuncture*
;
Metals*
4.Commercial Herbal Slimming Products: Evaluation of Heavy Metals and Microorganism Contamination at Different Batch Production
Nur Faizah Abu Bakar ; Noraziah Mohamad Zin ; Tuan Siti Mastazliha Long Tuan Kechik ; Jacinta Santhanam
Malaysian Journal of Health Sciences 2017;15(1):7-17
Herbal-based slimming products which are consumed orally may be contaminated with heavy metals as well as microorganisms. This study aimed to evaluate the safety level of these slimming products by determining heavy metals and microbial contamination in different batch production. Six different brands of herbal-based slimming products (A, B, C, G, H and I) with three different batch productions (1, 2 and 3) were investigated (n =18). Five heavy metals Arsenic, Cadmium, Chromium, Copper and Zinc were determined using an Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The presence of microorganisms was determined by total aerobic count and the bacteria were identified. The samples’ moisture content was determined by calculating the percentage of water loss after drying process. All batches of samples A and B had high content of zinc, over the permissible level of 5ppm while, 6 samples contained Chromium above the permissible level (1.5 ppm). All 3 batches of sample A presented with the highest total daily intake of heavy metals. Bacteria were present in all the samples tested with the highest numbers in samples G, H and A followed by B, I and C. The highest number of fungi was found in product A while product I was free from fungal contamination. Aspergillus spp. was the predominant fungus present in the samples. There was a weak correlation between moisture content and bacteria (r = 0.087) and fungal (r = 0.253) presence in the samples. As some herbal slimming products contain heavy metals as well as microorganisms, consumers need to be more vigilant and discerning when selecting products to be consumed.
Metals, Heavy
5.A study on the Heavy Metal Concentrations and Their Interrelationships in Women's Blood and Urine in small towns.
In Dam HWANG ; No Suk KI ; Jae Hyung LEE ; In Seo PARK
Korean Journal of Preventive Medicine 1987;20(1):49-55
The results of this study which had been investigated for the purpose of analyzing heavy metal concentrations in women's blood and urine, their correlation degree and significance of cadmium as indicator of accumulated heavy metals are as follows. 1) In blood, concentrations of Cd, Pb, Cu and Zn are respectively 0.0110+/-0.14 ug/ml, 0.208+/-138 ug/ml, 0.899+/-0.153 ug/ml and 5.432+/-1.020 ug/ml. 2) In urine, concentrations of Cd, Pb, Cu and Zn are respectively 0.003+/-0.12 ug/ml, 0.025+/-0.18 ug/ml, 0.013+/-0.12 ug/ml and 0.277+/-0.192 ug/ml. 3) Correlation coefficients between blood and urine are only significant in Zn (r=0.363, p<0.01). 4) In blood, correlation coefficients of Cd concentration and Pb, Zn are respectively 0.518 (p<0.01). 5) Correlation coefficients between Cd concentration in blood and Pb, Cu and Zn in urine are respectively r=-0.012, r=0.027, r=0.241 (p<0.05), and only Cd concentration and Zn is significant.
Cadmium
;
Metals, Heavy
6.Design and Dose Distribution of Docking Applicator for an Intraoperative Radiation Thherapy.
Sung Sil CHU ; Gwi Eon KIM ; John J L LOH
Journal of the Korean Society for Therapeutic Radiology 1991;9(1):123-130
A docking intraoperative electron beam applicator system, which is easily docking in the collimator for a linear accelerator after setting a sterilized transparent cone on the tumor bearing area in the operation room, has been designed to optimize dose distribution and to improve the efficiency of radiation treatment method with linear accelerator. This applicator system consisted of collimator holder with shielded metals and docking cone with transparent acrylic cylinder. A number of technical innovations have been used in the design of this system, this docking cone gives a improving latral dose coverage at therapeutic volume. The position of 90% isodose curve under surface of 8 cm diameter cone was extended 4~7 mm at 12 MeV electron and the isodose measurements beneath the cone wall showed hot spots as great as 106% for acrylic cone. The leakage radiation dose to tissues outside the cone wall was reduced as 3~5% of output dose. A comprehensive set of dosimetric characteristics of the intraoperative radiation therapy applicator system is presented.
Metals
;
Particle Accelerators
7.Investigate some heavy metals concentration: lead, cadmium, arsenic and mercury at fresh water fish and snail in Hanoi markets
Journal of Vietnamese Medicine 2003;288(9):85-91
By atomic absorbance spectrophotometry, the content of heavy metals (lead, cadmium, arsenic, mercure) in freshwater fish and shelfish in the market and in 2 lakes in Hanoi from June to December 2002 was analysed. The contents are: lead 100%, arsenic 98.5%, cadmium 92.9% and mercury 88.6%, they are in the tolerable limits according to 1998 year Vietnam MOH regulation 867/BYT. The contents of various heavy metals are not similar in diverse genera of fish and shelfish. In some genera of fish, arsenic contents are higher than average from 0..68 to 0.601 mg/kg and mercury content 0.053mg/kg. Heavy metal contents in 2 lakes of Thanh Tri district and in diverse markets in Hanoi have not significant differences
Metals, Heavy
;
Mercury
;
Lead
8.Bioaccumulation and non-carcinogenic health risk assessment of heavy metals in selected fish species from South Bay of Laguna Lake
Carmela Jhoy G. Mercado ; Liezl M. Atienza ; Clarissa B. Juanico ; Dinah Pura T. Depositario ; Wilma A. Hurtada
Acta Medica Philippina 2021;55(7):767-774
Objective:
The study aimed to determine the concentration of three heavy metals namely, lead (Pb), cadmium (Cd) and chromium (Cr) present in head, stomach and muscle parts of Nile Tilapia (Oreochromis niloticu) and Blackchin Tilapia (Sarotherodon melanotheron) collected from different sampling sites in South Bay area of Laguna Lake and evaluate its potential health risk for adult consumers.
Methods:
Live samples of Nile Tilapia and Blackchin Tilapia were hand-collected from three sites of South Bay of Laguna Lake during wet season. Raw and boiled samples were prepared for analysis. Heavy metal concentrations (mg kg-1) were determined through flame atomic absorption spectrophotometry (AAS). The potential health risk posed by more than one metal was calculated using the Total Hazard Quotient (THQ).
Results:
The heavy metal detected with the highest concentration was Pb, present in Nile Tilapia. The mean concentrations of Pb, Cd, and Cr in both fish samples were high in the head part. Boiled samples have significantly lower concentrations of heavy metal (p<0.05) compared to raw samples. THQ values for Cd in raw fish samples were higher than the recommended level of exposure (THQ < 1.0).
Conclusion
The study revealed that cadmium is of greater concern in terms of possible adverse health effects associated with heavy metal bioaccumulation. However, the presence of other metals may further increase the risk of non-carcinogenic adverse effects. The lower health risk is predicted for boiled fish samples.
Metals, Heavy
;
Cichlids
9.Atmospheric Concentration of Heavy Metals of Pusan Area.
In Hyeok SONG ; Gyu Il CHO ; Deog Hwan MOON ; Chang Hee LEE ; Jung Hak KANG ; Jong Gab KIM ; Yong Soo HAN ; Chae Un LEE
Korean Journal of Preventive Medicine 1995;28(3):726-733
This study was carried out to assess the present level of atmospheric metals. Five metals-lead, cadmium, chromium, manganese, vanadium-were checked on the industrial(Sasang) and residental area(Daeshindong) in the city of Pusan sampling period was the year of 1986, 1990, and 1994, and the sampling time was 2 days of each site. As the result of comparison with the atmospheric standard of ASHRAE(1980) the average concentrations of lead was above the standard, the average concentrations of chromium was around the standard, and the average concentrations of cadmium and vanadium was below the standard. The average concentrations of manganese was above the standard of industrial environment. And the average concentrations of five metals was higher in the industrial area than the residental area The average concentrations of lead cadmium and chromium showed the increase tendency by the year, and the average concentrations of vanadium showed no change, and the average concentrations of manganese showed the decrease tendency. As a result of correlation analysis, lead and cadmium(r=0.31), vanadium and manganese(r=0.24), vanadium and chromium(r=0.19) showed significance.
Busan*
;
Cadmium
;
Chromium
;
Manganese
;
Metals
;
Metals, Heavy*
;
Vanadium
10.Research on the impact of metal implants with different materials on radiation dose distribution.
Ruiyao JIANG ; Fei XIONG ; Guofeng HUANG
Chinese Journal of Medical Instrumentation 2013;37(4):301-303
OBJECTIVETo investigate the impact of metal implants with different materials on radiation dose distribution based on film measurement method.
METHODSTitanium plate, titanium intramedullary pin and stainless steel plate were set into phantom and irradiated separately by 6 MV and 15 MV X ray from linear accelerator. Dose distributions derived from different materials metal implants were measured and analyzed by film dosimeter.
RESULTSFor 6 MV X ray, the maximum interface dose increments of titanium plate, titanium intramedullary pin and stainless steel plate were 12.3%, 15.4% and 20.3%. As the radiation energy was increased from 6 MV to 15MV, the maximum interface dose increment of the titanium plate rose from 12.3% to 15.1%, the maximum interface dose increment of the steel plate rose from 20.3% to 30.8%.
CONCLUSIONSMetal implants with different materials have obvious impact on radiation dose distribution. With the increase of the metal atomic number and energy of radiation, the degree of elevated dose also increases. These results suggest that correction of dose distribution is required for radiotherapy of patients with metal implants.
Metals ; Prostheses and Implants ; Radiotherapy Dosage