1.Development of measurement and control technologies for hyperthermia treatments of tumors with AC magnetic field.
Zhong-hua GUO ; Lu-xin TANG ; Jin-tian TANG ; Bin XIE ; Xiao-hui DENG
Chinese Journal of Medical Instrumentation 2006;30(1):39-42
Hyperthermia therapy with AC magnetic field heating magnetic nanoparticles is a new kind of treatment method. The paper reviews the research progresses about AC magnetic heating setups for hyperthermia therapy measurements of magnetic field temperature control, and so on.
Humans
;
Hyperthermia, Induced
;
methods
;
Magnetics
;
Nanotechnology
;
Neoplasms
;
therapy
2.Progress of application in non-invasive temperature monitoring of hyperthermia using B-ultrasound.
Hao ZHU ; Chunlan YANG ; Shuicai WU
Journal of Biomedical Engineering 2010;27(3):680-683
Hyperthermia is a significant and promising technique for tumor treatment. Temperature is the key parameter which influences the treatment effectiveness. Therefore, real-time and precise noninvasive temperature monitoring is the pivotal issue in further development of hyperthermia. This paper introduced the noninvasive monitoring theories and techniques of hyperthermia based on ultrasonic image texture features, and reviewed the achievements both abroad and at home. In addition, some problems to be solved necessary were also pointed out.
Animals
;
Body Temperature
;
Humans
;
Hyperthermia, Induced
;
methods
;
Monitoring, Physiologic
;
methods
;
Neoplasms
;
therapy
;
Thermometers
;
Ultrasonics
;
methods
3.Development of a cryosurgery & radiofrequency alternating tumor ablation device.
Xiao-Gang FU ; Jing-Feng BAI ; Yazhu CHEN
Chinese Journal of Medical Instrumentation 2008;32(6):413-415
The combination of the cryosurgery using LN2 and intelligent RF ablation therapeutic instrument based on the theory of local destruction is introduced in this paper, and this alternating therapy is believed to have a better controlling effect on tumor ablation. In heating period, a fuzzy algorithm is used to control the RF power to realize a more smoothly heating process to the target area.
Catheter Ablation
;
instrumentation
;
methods
;
Cryosurgery
;
instrumentation
;
Equipment Design
;
Humans
;
Hyperthermia, Induced
;
instrumentation
;
methods
;
Neoplasms
;
surgery
4.Design of an microwave applicator using for tumor in superficial layer.
Bing SUN ; Xiaofeng LU ; Yi CAO
Chinese Journal of Medical Instrumentation 2010;34(3):198-201
OBJECTIVEA 2.45 GHz microstrip applicator using single rectangle sheet structure is presented.
METHODSBased on the radiant principle of microstrip antenna, the applicator's parameter is designed and the simulating model is set and optimized in HFSS.
RESULTSMeasured by network analyzer, the technical target of this applicator is complied with design demand. During irradiation experiment, based on 30 W power, 30 mm radiation distance and 15 min duration experiment condition, the thermal field distribution map of phantom is obtained from the far-infrared image instrument. The 3D map shows that the region of thermal field centre has small radius and deep heat penetration.
CONCLUSIONThe microwave energy from this applicator can reach the tumor in superficial layer without heat injuring normal tissue around it.
Equipment Design ; Hyperthermia, Induced ; instrumentation ; methods ; Microwaves ; therapeutic use ; Neoplasms ; therapy
5.Development and application of ultrasound technology for hyperthermia.
Liang ZHAI ; Fu-cheng SUN ; Ji-wei JIANG ; Xiang-ling XIAO ; Xiao-ping QIAN ; Yi-kang WANG ; Ren-kang YU ; Yong-jiang XU ; Hong-feng ZHANG
Chinese Journal of Medical Instrumentation 2002;26(4):281-280
It has been a long time since ultrasound hyperthermia began to be used in the clinical management of cancers and benign diseases. Numerous biological and clinical investigations have demonstrated that: hyperthermia in the range of 41-45 degrees C can significantly enhance clinical response to radiation therapy and chemotherapy, and high-temperature hyperthermia (greater than 65 degrees C) alone is now being used as an alternative to conventional invasive surgery for selective tissue destruction, causing tumor coagulation and necrosis. As a promising noninvasive and effective local therapy, HIFU has attracted great attention. China is advanced in the clinical applications of HIFU. This article gives an introduction of the development and applications of ultrasound hyperthermia technology, and also provides a general review of a selection of ultrasound hyperthermia systems both in clinical use and under development.
Equipment Design
;
Humans
;
Hyperthermia, Induced
;
instrumentation
;
methods
;
Neoplasms
;
therapy
;
Ultrasonics
;
Ultrasound, High-Intensity Focused, Transrectal
6.Design of double ultrasound pulse transmitting and receiving circuits used in ultrasound thermometry.
Ya-qin XIA ; Li-qin JIA ; Jian-shu PENG ; Shui-cai WU
Chinese Journal of Medical Instrumentation 2002;26(4):245-285
This paper introduces double ultrasound pulse transmitting and receiving circuits used in ultrasound thermometry. Using the circuits, double ultrasound pulses could be made synchronously to satisfy the requirements of ultrasound thermometry, and the weak ultrasound echo signals are received successfully. The crux experiment waveform offered shows that the circuits have high reliability.
Equipment Design
;
Humans
;
Hyperthermia, Induced
;
instrumentation
;
Neoplasms
;
therapy
;
Pulse
;
Temperature
;
Transducers
;
Ultrasonography
;
instrumentation
;
methods
7.Research of high precision of temperature measurement in microwave hyperthermia therapy.
Hua WANG ; Chi TANG ; Xiaoyu FAN ; Guosheng YANG
Chinese Journal of Medical Instrumentation 2002;26(5):332-341
This paper describes a new method of temperature measurement in microwave field. This method resolves a series of problems such as the microwave field suppression, the linearization of the temperature sensor and the sensor exchangeability.
Electricity
;
Equipment Design
;
Humans
;
Hyperthermia, Induced
;
instrumentation
;
methods
;
Linear Models
;
Microwaves
;
therapeutic use
;
Neoplasms
;
therapy
8.Design of a miniaturized blood temperature-varying system based on computer distributed control.
Qiang XU ; Zhaoying ZHOU ; Jiegang PENG ; Junhua ZHU
Journal of Biomedical Engineering 2007;24(5):969-972
Blood temperature-varying has been widely applied in clinical practice such as extracorporeal circulation for whole-body perfusion hyperthermia (WBPH), body rewarming and blood temperature-varying in organ transplantation. This paper reports a novel DCS (Computer distributed control)-based blood temperature-varying system which includes therapy management function and whose hardware and software can be extended easily. Simulation results illustrate that this system provides precise temperature control with good performance in various operation conditions.
Body Temperature
;
Computing Methodologies
;
Equipment Design
;
Humans
;
Hyperthermia, Induced
;
instrumentation
;
methods
;
Software
9.System design of small intellectualized ultrasound hyperthermia instrument in the LabVIEW environment.
Feng JIANG ; Jingfeng BAI ; Yazhu CHEN
Journal of Biomedical Engineering 2005;22(4):836-839
Small-scale intellectualized medical instrument has attracted great attention in the field of biomedical engineering, and LabVIEW (Laboratory Virtual Instrument Engineering Workbench) provides a convenient environment for this application due to its inherent advantages. The principle and system structure of the hyperthermia instrument are presented. Type T thermocouples are employed as thermotransducers, whose amplifier consists of two stages, providing built-in ice point compensation and thus improving work stability over temperature. Control signals produced by specially designed circuit drive the programmable counter/timer 8254 chip to generate PWM (Pulse width modulation) wave, which is used as ultrasound radiation energy control signal. Subroutine design topics such as inner-tissue real time feedback temperature control algorithm, water temperature control in the ultrasound applicator are also described. In the cancer tissue temperature control subroutine, the authors exert new improvments to PID (Proportional Integral Differential) algorithm according to the specific demands of the system and achieve strict temperature control to the target tissue region. The system design and PID algorithm improvement have experimentally proved to be reliable and excellent, meeting the requirements of the hyperthermia system.
Algorithms
;
Computer Simulation
;
Hyperthermia, Induced
;
instrumentation
;
Neoplasms
;
therapy
;
Software Design
;
Ultrasonic Therapy
;
instrumentation
;
methods
10.Recent advances on physical ablation for tumor.
Chengxiang LI ; Chenguo YAO ; Yaen MI ; Zheng'ai XIONG
Journal of Biomedical Engineering 2009;26(5):1137-1140
Physical ablation is a new kind of tumor treatment which directly acts on local solid tumors to eradicate or destroy tumor tissues by use of various advanced physical techniques. Physical ablation can be classified by physical characteristics as thermal ablate therapy (TAT), cryoablation and electrical ablation. Recent studies and technical trend of these three physical ablation treatments are reviewed in this paper.
Animals
;
Catheter Ablation
;
methods
;
Cryosurgery
;
Humans
;
Hyperthermia, Induced
;
Neoplasms
;
surgery
;
therapy
;
Salvage Therapy