2.Global air monitoring study: a multi-country comparison of levels of indoor air pollution in different workplaces.
Heng Nung KOONG ; Deborah KHOO ; Cheryl HIGBEE ; Mark TRAVERS ; Andrew HYLAND ; K Michael CUMMINGS ; Carolyn DRESLER
Annals of the Academy of Medicine, Singapore 2009;38(3):202-206
INTRODUCTIONA local study completed in Singapore, which was part of an international multi-country study that aims to develop a global assessment of exposure to second-hand smoke in indoor workplaces, gathered data regarding the indoor air quality of public areas. It was hypothesised that air would be less polluted in non-smoking venues compared to places where smoking occurred.
MATERIALS AND METHODSA TSI SidePak AM510 Personal Aerosol Monitor was used to sample and record the levels of respirable suspended particles (RSP) in the air. A broad range of venues were sampled in Singapore. The primary goal of data analysis was to assess the difference in the average levels of RSP in smoke-free and non smoke-free venues. Data was assessed at 3 levels: (a) the mean RSP across all venues sampled compared with the mean levels of smoke-free and non smoke-free venues, (b) levels in venues where smoking occurred compared with similar venues in Ireland, and (c) comparison between smoke-free and non smoke-free areas according to the type of venue. Statistical significance was assessed using the Mann-Whitney U-test.
RESULTSThe level of indoor air pollution was 96% lower in smoke-free venues compared to non smoke-free venues. Averaged across each type of venue, the lowest levels of indoor air pollution were found in restaurants (17 microg/m3) and the highest in bars (622 microg/m3); both well above the US EPA Air Quality Index hazardous level of >or=251 ug/m3.
CONCLUSIONSThis study demonstrates that workers and patrons are exposed to harmful levels of a known carcinogen and toxin. Policies that prohibit smoking in public areas dramatically reduce exposure and improve worker and patron health.
Air Pollution, Indoor ; analysis ; legislation & jurisprudence ; Environmental Monitoring ; Ireland ; Restaurants ; Singapore ; Smoking ; Workplace
3.Study on the level of tobacco-generated smoke in several restautants and bars in Beijing, China.
Ji-Ming KANG ; Yuan JIANG ; Xiao-Guang LIN ; Yan YANG ; Yi NAN ; Zhu LI ; Rui-Ling LIU ; Guo-Ze FENG ; Xiao-Shuai WEI ; Mark J TRAVERS ; Qiang LI ; Andrew HYLAND
Chinese Journal of Epidemiology 2007;28(8):738-741
OBJECTIVETo investigate the current smoking regulations and their impacts on the environmental tobacco smoke (ETS) levels inside restaurants and bars in Beijing.
METHODSTelephone survey was used to investigate the smoking regulations. TSI Sidepak AM510 was used to measure the level of fine particles less than 2.5 microns in diameter (PM2.5) in restaurants and bars. Analysis of variance and non-parametric rank tests were used to examine the association between indoor and outdoor PM2.5 levels and (1) smoking regulations; and (2) types of restaurants and bars.
RESULTSOf the 305 restaurants and bars surveyed, 27.9% had complete or partial smoking prohibiting rules. The average indoor PM2.5, level of the 92 restaurants and bars was 253.08 microg/m3 , 102.37% higher than the outdoor level. The average indoor and outdoor PM2.5 levels in the restaurants and bars with smoking ban regulations were 93.10 microg/m3 and 110.33 microg/m3 whole 289.34 microg/m3 and 128.40 microg/m3 in those without, respectively. The average indoor and outdoor PM2.5 levels of bars were 413.46 microg/m3 and 190.62 microg/m3, respectively, while in the western fast-food restaurants, they were 83.86 microg/m3 and 104.77 microg/m3, respectively. The outdoor PM2.5 levels were higher than the indoor levels in different classes of restaurants and bars. Furthermore, there was a significant positive correlation between PM2.5 levels and the number of smokers per cube meters (r = 0.47, P < 0.001).
CONCLUSIONSmoking regulations could effectively reduce the ETS level in restaurants and bars.
Air Pollution, Indoor ; analysis ; legislation & jurisprudence ; China ; Environmental Monitoring ; Particulate Matter ; analysis ; Restaurants ; Smoking ; legislation & jurisprudence ; Tobacco Smoke Pollution ; analysis ; legislation & jurisprudence
4.Management System of Occupational Diseases in Korea: Statistics, Report and Monitoring System.
Kyung Yong RHEE ; Seong Weon CHOE
Journal of Korean Medical Science 2010;25(Suppl):S119-S126
The management system of occupational diseases in Korea can be assessed from the perspective of a surveillance system. Workers' compensation insurance reports are used to produce official statistics on occupational diseases in Korea. National working conditions surveys are used to monitor the magnitude of work-related symptoms and signs in the labor force. A health examination program was introduced to detect occupational diseases through both selective and mass screening programs. The Working Environment Measurement Institution assesses workers' exposure to hazards in the workplace. Government regulates that the employer should do health examinations and working conditions measurement through contracted private agencies and following the Occupational Safety and Health Act. It is hoped that these institutions may be able to effectively detect and monitor occupational diseases and hazards in the workplace. In view of this, the occupational management system in Korea is well designed, except for the national survey system. In the future, national surveys for detection of hazards and ill-health outcomes in workers should be developed. The existing surveillance system for occupational disease can be improved by providing more refined information through statistical analysis of surveillance data.
Accidents, Occupational/statistics & numerical data
;
*Environmental Monitoring/legislation & jurisprudence
;
Female
;
Humans
;
Male
;
*Occupational Diseases
;
Occupational Exposure
;
*Occupational Health/legislation & jurisprudence
;
*Occupational Health Services/legislation & jurisprudence
;
*Population Surveillance
;
Republic of Korea
;
Workplace