1.Total Hip Arthroplasty around the Inception of the Interface Bioactive Bone Cement Technique.
Hiroyuki OONISHI ; Hirotsugu OHASHI ; Ikuo KAWAHARA
Clinics in Orthopedic Surgery 2016;8(3):237-242
BACKGROUND: To augment cement-bone fixation, Dr. Hironobu Oonishi attempted additional physicochemical bonding through interposition of osteoconductive crystal hydroxyapatite (HA) granules at the cement-bone interface in 1982. He first used the interface bioactive bone cement (IBBC) technique in 12 selected patients (12 hips) in 1982 (first stage) and followed them for 2 years. In 1985, the technique was applied in 25 total hip arthroplasty (THA) patients (second stage) and the effects were investigated by comparing the side with the IBBC technique and the other side without the IBBC technique. He has employed this technique in all THA patients since 1987 (third stage). METHODS: In the IBBC technique, HA granules (2 to 3 g) were smeared on the bone surface just before the acetabular and femoral components were cemented. In the first stage, 12 hips were operated using the IBBC technique in 1982. In the second stage, THA was performed without the IBBC technique on one side and with the IBBC technique on the other side within 1 year in 25 patients. In the third stage, THA was performed with the IBBC technique in 285 hips in 1987. RESULTS: In the first stage patients, implant loosening was not detected at 30 years after operation. In the second stage patients, revision was required in 7 hips without the IBBC technique due to cup loosening (5 hips) and stem loosening (2 hips), whereas no hip was revised after THA with the IBBC technique at 26 years after operation. In the third stage patients, the incidence of radiolucent lines and osteolysis was very few at 25 years after operation. CONCLUSIONS: The long-term follow-up of THA performed around the inception of the IBBC technique has revealed low incidences of radiolucent lines, osteolysis, and revision surgery.
Adult
;
Aged
;
Aged, 80 and over
;
*Arthroplasty, Replacement, Hip/adverse effects/instrumentation/methods
;
*Bone Cements/adverse effects/therapeutic use
;
Bone-Implant Interface/physiology
;
Follow-Up Studies
;
Hip/diagnostic imaging/surgery
;
Humans
;
Hydroxyapatites/therapeutic use
;
Middle Aged
;
Young Adult
2.Ceramic-on-Ceramic Total Hip Arthroplasty: Minimum of Six-Year Follow-up Study.
Won Sik CHOY ; Kap Jung KIM ; Sang Ki LEE ; Kyoung Wan BAE ; Yoon Sub HWANG ; Chang Kyu PARK
Clinics in Orthopedic Surgery 2013;5(3):174-179
BACKGROUND: This study examines the clinical and radiologic results of ceramic-on-ceramic total hip arthroplasties with regard to wear, osteolysis, and fracture of the ceramic after a minimum follow-up of six years. METHODS: We evaluated the results of a consecutive series of 148 primary ceramic-on-ceramic total hip arthroplasties that had been performed between May 2001 and October 2005 in 142 patients. The mean age was 57.2 years (range, 23 to 81 years). The mean follow-up period was 7.8 years (range, 6.1 to 10.1 years). Preoperative diagnosis was avascular necrosis in 77 hips (52%), degenerative arthritis in 36 hips (24.3%), femur neck fracture in 18 hips (12.2%), rheumatoid arthritis in 15 hips (10.1%), and septic hip sequelae in 2 hips (1.4%). Clinical results were evaluated with the Harris hip score, and the presence of postoperative groin or thigh pain. Radiologic analysis was done with special attention in terms of wear, periprosthetic osteolysis, and ceramic failures. RESULTS: The mean Harris hip score improved from 58.3 (range, 10 to 73) to 92.5 (range, 79 to 100) on the latest follow-up evaluation. At final follow-up, groin pain was found in 4 hips (2.7%), and thigh pain was found in 6 hips (4.1%). Radiologically, all femoral stems demonstrated stable fixations without loosening. Radiolucent lines were observed around the stem in 25 hips (16.9%), and around the cup in 4 hips (2.7%). Endosteal new bone formation was observed around the stem in 95 hips (64.2%) and around the cup in 88 hips (59.5%). No osteolysis was observed around the stem and cup. There were 2 hips (1.4%) of inclination changes of acetabular cup, 2 hips (1.4%) of hip dislocation, 1 hip (0.7%) of ceramic head fracture, and 1 hip (0.7%) of squeaking. The Kaplan-Meier survival rate of the prostheses was 98.1% at postoperative 7.8 years. CONCLUSIONS: The ceramic-on-ceramic total hip arthroplasty produced excellent clinical results and implant survival rates with no detectable osteolysis on a minimum six-year follow-up study. The ceramic-on-ceramic couplings could be a reasonable option of primary total hip arthroplasty for variable indications.
Adult
;
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/adverse effects/instrumentation/*methods
;
*Ceramics
;
Female
;
Follow-Up Studies
;
Hip Joint/radiography/surgery
;
*Hip Prosthesis
;
Humans
;
Kaplan-Meier Estimate
;
Male
;
Middle Aged
;
Pain, Postoperative/etiology
;
Prosthesis Failure
;
Range of Motion, Articular