1.Comparison of Total and IgG ABO Antibody Titers in Healthy Individuals by Using Tube and Column Agglutination Techniques.
Eun Su PARK ; Kyung Il JO ; Jeong Won SHIN ; Rojin PARK ; Tae Yoon CHOI ; Hae In BANG ; Gum Ran CHAI ; Soon Gyu YUN
Annals of Laboratory Medicine 2014;34(3):223-229
BACKGROUND: Most immune reactions related to transfusion and transplantation are caused by IgM ABO antibodies. However, IgG also plays an important role in these reactions. Therefore, a method to measure antibodies, including IgG, is necessary. We investigated ABO antibody titers of healthy individuals using a column agglutination technique (CAT) with or without dithiothreitol (DTT) and compared them with titers obtained using a conventional tube method. METHODS: Among healthy adults who underwent a medical examination, 180 individuals (60 with blood group A, 60 with group B, and 60 with group O) were selected. Antibody titrations were performed using the immediate spin (IS) tube, anti-human globulin (AHG) tube, and CAT with or without DTT methods. RESULTS: Higher median values of anti-B and anti-A titers in groups A and B individuals, respectively, were obtained using the IS method than using the AHG method. Higher values for group O individuals were obtained using the AHG method. Higher median titers of anti-B and anti-A in group O individuals were obtained using CAT without DTT than using the AHG method. Median titers of anti-B and anti-A in all blood groups were higher in CAT without DTT than in CAT with DTT, especially for group O individuals. CONCLUSIONS: We recommend CAT with and without DTT for titration of anti-A and anti-B, especially in group O individuals, to provide more sensitive results that include IgG data. Adjustment of insurance coverage of fees associated with antibody titration might be necessary, considering the actual cost of reagents and personnel.
ABO Blood-Group System/*immunology
;
Adult
;
*Agglutination Tests/instrumentation
;
Antibodies/*analysis/immunology
;
Female
;
Humans
;
Immunoglobulin G/immunology
;
Male
;
Middle Aged
2.Comparison of ABO Antibody Titers on the Basis of the Antibody Detection Method Used.
Seon Joo KANG ; Young Ae LIM ; Sae Yun BAIK
Annals of Laboratory Medicine 2014;34(4):300-306
BACKGROUND: Detection methods for ABO antibody (Ab) titers vary across laboratories, and the results are different depending on the method used. We aimed to compare titer values using different detection methods for the measurement of ABO Ab titers. METHODS: For ABO Ab detection, pooled group A or B red blood cells (RBCs) were reacted with each of 20 sera from blood groups A, B, or O without dithiothreitol treatment. The room-temperature (RT) incubation technique and the indirect antiglobulin test (IAT) were used in the tube test and gel card test. Flow cytometry (FCM) was performed by using anti-IgM and anti-IgG Abs. RESULTS: Regardless of the blood groups tested, the FCM assay with anti-IgM showed the highest titer compared to the tube test and gel card test with RT incubation in both. The tube test with IAT showed a higher titer than the gel card test with IAT (Gel-IAT) or FCM with anti-IgG in blood group A and B, while Gel-IAT showed the highest titer relative to the other tests, only for the anti-A Ab in blood group O. CONCLUSIONS: There were significant differences in the titers depending on the detection method used, and each method showed a different detection capacity for each ABO Ab depending on the ABO blood group tested. Therefore, caution should be exercised in interpreting ABO Ab titer results, taking into consideration the detection method used and the blood group.
ABO Blood-Group System/*immunology
;
Adult
;
Aged
;
Agglutination Tests/instrumentation/*standards
;
Antibodies/*analysis
;
Antibodies, Anti-Idiotypic/analysis
;
Erythrocytes/chemistry/metabolism
;
Female
;
*Flow Cytometry
;
Humans
;
Male
;
Middle Aged
;
Temperature