Development and verification of a sulfosalicylic acid spectrophotometric method for determination of iron ion in medium for producing diphtheria toxin
10.13200/j.cnki.cjb.004012
- VernacularTitle:白喉产毒培养基中铁离子磺基水杨酸分光光度检测方法的建立及验证
- Author:
WEN Jiana
- Publication Type:Journal Article
- Keywords:
Diphtheria;
Diphtheria toxin;
Iron ion;
Sulfosalicylic acid;
Spectrophotometry
- From:
Chinese Journal of Biologicals
2023;36(10):1242-1247
- CountryChina
- Language:Chinese
-
Abstract:
Objective To develop and verify a sulfosalicylic acid spectrophotometric method for the determination of trace iron ions in diphtheria toxin medium,and apply it preliminarily.Methods The maximum absorbance of the complex of iron and sulfosalicylic acid was scanned by full spectrum;A method for the determination of iron ion in culture medium was developed by linear regression between the absorbance of the complex and the content of iron ion,and the stability,accuracy and precision of the method were verified.The effects of Ca~(2+),Mg~(2+),K~+,Na~+ and reactants on the method were investigated.Spectrophotometric method with sulfosalicylic acid was used to determine trace iron in the self-made and commercial medium for diphtheria toxin production.Sulfosalicylic acid spectrophotometry,ferrizine colorimetry and o-phenanthroline spectrophotometry were used to detect iron content in two kinds of culture media(beef trypsin digestion liquid and 5% polypeptone),and the detection results of the three methods were compared.Results The complex of iron and sulfosalicylic acid showed the maximum absorbance at the wavelength of 425 nm;There was a good linear relationship between the absorbance and concentration of iron ion in the range of 1~0.05 μg/mL,the detection limit was 0.05 μg/mL,and the standard equation was:Y=0.027 9 X+0.046 1,R~2> 0.99;The coefficients of variation(CVs) of A_(425) value of each concentration of standards measured every 5 min were less than 5%;Low(0.05 μg/mL),medium(0.5 μg/mL)and high concentration(1 μg/mL) of Fe~(3+) standard solutions were continuously determined for 3 times.The CVs of 9groups of each concentration measured in parallel were all less than 5% and the recovery rates were higher than 95%;Ca~(2+),Mg~(2+),K~+,Na~+,15 μL of sulfo salicylic acid(20%) and 50 μL of ammonia hydroxide(1:1) showed no interference in the method;The results of toxin-producing medium were consistent with those of diphtheria bacteria;The results of the three detection methods were consistent.Conclusion The developed spectrophotometric method with sulfo salicylic acid can determine the content of trace iron ions in diphtheria toxin medium accurately and effectively.