Effect of transcutaneous electrical acupoint stimulation on postoperative pulmonary function in patients undergoing robot-assisted radical resection of colon cancer
10.3760/cma.j.cn131073.20230207.00607
- VernacularTitle:经皮穴位电刺激对机器人辅助结肠癌根治术患者术后肺功能的影响
- Author:
Yuming TU
1
;
Shunyan LIN
;
Ju GAO
;
Yinyin DING
;
Lulu XU
Author Information
1. 江苏省苏北人民医院麻醉科,扬州 225001
- Keywords:
Transcutaneous electric nerve stimulation;
Respiratory function tests;
Colonic neoplasms;
Robotic surgical procedures
- From:
Chinese Journal of Anesthesiology
2023;43(6):682-687
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the effect of transcutaneous electrical acupoint stimulation (TEAS) on postoperative pulmonary function in the patients undergoing robot-assisted radical resection of colon cancer.Method:Ninety-four patients of either sex, aged 50-80 yr, with body mass index of 18-25 kg/m 2, of American Society of Anesthesiologists physical status Ⅰ-Ⅲ, with ARISCAT grade of medium risk, undergoing elective robot-assisted radical resection of colon cancer, were enrolled in this study. The patients were divided into TEAS group (group T, n=47) and sham-TEAS group (group S, n=47) using a random number table method. In group T, patients received 30 min of TEAS at Hegu (LI4), Quchi (LI11), Zusanli (ST36) and Feishu (BL13) between 5: 00 and 7: 00 a. m. from 1st day before operation to 3rd day after operation, with disperse-dense wave 2/100 Hz, and the stimulation intensity was the maximum intensity that the patient could tolerate. Patients in group S were also connected to the device without electrical stimulation. Both groups adopted lung-protective ventilation strategy during operation. The oxygenation index was calculated at the time of entering the operating room (T 0), 5 min after anesthesia induction (T 1), 5 min of pneumoperitoneum (T 2), 5 min after changing to Trendelenburg position (T 3) and immediately after the end of pneumoperitoneum (T 4). Peak airway pressure, plateau airway pressure, driving pressure and dynamic lung compliance were recorded at T 0-T 4. The serum concentration of lung Clara cell 16 kDa protein was recorded using enzyme-linked immunosorbent assay at T 0, T 4 and 2 h after extubation (T 5). On 1 day before operation and 1, 3 and 7 days after operation, the forced expiratory volume in the first second (FEV 1) and forced vital capacity (FVC) were measured, and the FEV 1/FVC was calculated, and the concentrations of serum tumor necrosis factor-alpha, interleukin-6 and cardiopulmonary resuscitation were simultaneously determined using enzyme-linked immunosorbent assay. The occurrence of pulmonary complications within 7 days after operation was recorded. Results:There was no significant difference in pH values, PaCO 2, oxygenation index, peak airway pressure, plateau airway pressure, driving pressure, and dynamic lung compliance at each time point between the two groups ( P>0.05). Compared with S group, the serum Clara cell 16 kDa protein concentrations were significantly decreased at T 5, FEV 1 and FVC were increased at 3 and 7 days after operation, the serum tumor necrosis factor-alpha, interleukin-6 and cardiopulmonary resuscitation concentrations were decreased at 1, 3 and 7 days after operation, the incidence of unexpected oxygen supply and total incidence of postoperative pulmonary complications were decreased ( P<0.05), and no significant change was found in FEV 1/FVC at each time point in T group ( P>0.05). Conclusions:TEAS can improve lung function in the patients undergoing robot-assisted radical resection of colon cancer.