Analysis of abnormal results of individual dose monitoring for radiation workers in medical institutions in Henan province from 2020 to 2022
10.3760/cma.j.cn112271-20221113-00444
- VernacularTitle:2020-2022年度河南省医疗机构放射工作人员个人剂量监测异常结果分析
- Author:
Caifang CHU
1
;
Yanfang ZHAO
;
Yuanbo CHENG
;
Juanjuan LIANG
;
Qinfu ZHANG
Author Information
1. 河南省第三人民医院 河南省职业病医院质量控制办公室,郑州 450052
- Keywords:
Personal dose monitoring;
Abnormal results;
Radiation workers
- From:
Chinese Journal of Radiological Medicine and Protection
2023;43(5):366-372
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To analyze the abnormal dose monitoring result of radiation staff in medical institutions and provide a basis for standardizing the personal dose management of radiation staff in medical institutions.Methods:Through the occupational radiation disease monitoring subsystem of the National Radiation Health Information Platform, 516 individual dose monitoring abnormal result of 410 radiation workers in a single monitoring period, which in 168 medical institutions under the 18 cities in Henan province were collected from 2020 to 2022 as research objects. Based on gender, age, length of service, occupational category, medical institution level, whether the dosimeter wearing standard, the abnormal result of radiation workers were grouped to analyze the influencing factors of individual dose monitoring result.Results:The incidence of abnormal individual dose monitoring result in 2020-2022 was 6.83 × 10 -3, 5.22 × 10 -3 and 6.30 × 10 -3, respectively. Abnormal results were mainly distributed in male radiology workers (66.83%), diagnostic radiology (59.51%) and interventional radiology (34.63%), tertiary (54.39%) and secondary medical institutions (36.34%). In the case of wearing personal dosimeter in a standard or irregular way, there were statistically significant differences in the incidence of abnormal outcomes between different levels of medical institutions and different occupational categories( χ2=14.42, 6.56, 32.96, 177.15, P<0.05). The median annual individual dose of radiology workers with " abnormal exposure dose" due to increased workload was 3.95 mSv, and the annual individual dose of interventional radiology workers was higher than that of radiotherapeutic workers ( Z=5.07, P<0.05). Conclusions:The education and training of radiological protection should be strengthened, and the wearing of individual dosimeters should be standardized; focus on the occupational exposure of interventional radiology staff, and take effective measures to reduce their exposure dose.