Feasibility and accuracy of dual-energy CT multiparameter technique in evaluating myocardial scar in patients with heart failure
10.3760/cma.j.cn112149-20230113-00037
- VernacularTitle:双能量CT多参数技术评估心力衰竭患者心肌瘢痕的可行性与准确度
- Author:
Qian GUO
1
;
Jun SHAO
;
Jiashen JIANG
;
Sumeng WU
;
Linsheng SHI
;
Jun LIU
;
Tianle WANG
;
Shenchu GONG
;
Rongxing QI
Author Information
1. 南通市第一人民医院 南通大学第二附属医院影像科,南通 226001
- Keywords:
Tomography, X-ray computed;
Magnetic resonance imaging;
Myocardial delayed enhancement
- From:
Chinese Journal of Radiology
2023;57(4):390-396
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the reliability of cardiac late iodine enhancement dual-energy CT (LIE-DECT) multiparameter post-processing technique for evaluating the presence, location, and extent of cardiac scars in patients with heart failure (HF), using cardiac MR (CMR) late gadolinium enhancement (LGE) as a reference standard.Methods:Thirty-nine HF patients who underwent cardiac LIE-DECT and LGE-CMR examinations in the Second Affiliated Hospital of Nantong University from November 2019 to November 2021 were prospectively collected, all enrolled HF patients underwent LIE-DECT post-processing to reconstruct monoenergetic plus (Mono+) map (40 keV), iodine map and Rho/Z map, to evaluate the enhancement degree, location and extent of left ventricular myocardial LIE on the left ventricular short-axis map, respectively, and compared with LGE-CMR. Cohen′s Kappa test was used to assess the intra-and inter-observer consistency of LIE by DECT multiparameter technique and the consistency of LIE presence and location by DECT multiparameter technique and by CMR. The diagnostic efficacy of DECT multiparameter technique in diagnosing myocardial scar was calculated.Results:Of the 39 patients included, 32 patients were detected by CMR with LGE in 147 segments, including 37 subendocardial patterns, 19 transmural patterns, 74 mid-wall patterns, and 17 epicardial patterns. The intra-observer consistency Kappa values of 40 keV Mono+map, iodine map and Rho/Z map were 0.878, 0.930 and 0.835 ( P all<0.001), respectively. The inter-observer consistency Kappa values were 0.838, 0.892 and 0.808 ( P all<0.001), respectively. The LIE of 40 keV Mono+map, iodine map and Rho/Z map were in good agreement with CMR, Kappa values were 0.903, 0.883 and 0.810 ( P all<0.001), respectively. For the per-patient analysis, the accuracies of 40 keV Mono+map, iodine map and Rho/Z map were 92.3% (36/39), 92.3% (36/39) and 82.1% (32/39), respectively. For the segment-based analysis, the accuracies of 40 keV Mono+map, iodine map and Rho/Z map accuracy were 96.1% (492/512), 95.3% (488/512) and 92.6% (474/512), respectively. In Bland-Altman analysis, the consistency bias between scar extent measured by 40 keV Mono+map, iodine map, Rho/Z map and that measured by LGE-CMR were -2.03%, -2.21%, -2.65%, and the 95% limit of agreement were -12.20%-8.14%, -12.69%-8.28% and -14.85%-9.58%, respectively. Conclusion:LIE-DECT multiparameter technique can detect myocardial scar in HF patients well, which is consistent with LGE-CMR.