Study of extracting key plane of 11-13 + 6 weeks normal fetal palate by three-dimensional ultrasound based on artificial intelligence
10.3760/cma.j.cn131148-20220811-00553
- VernacularTitle:基于人工智能的三维超声自动断层成像提取11~13 +6周正常胎儿腭骨关键切面的初步研究
- Author:
Wenxiong PAN
1
;
Dandan ZHANG
;
Ruijuan PAN
;
Yuhao HUANG
;
Shihua DENG
;
Yuanji ZHANG
;
Mali ZHENG
;
Dong NI
;
Mei LI
;
Yi XIONG
Author Information
1. 深圳大学第三附属医院 深圳市罗湖区人民医院超声科,深圳 518020
- Keywords:
Ultrasonography, three-dimensional;
Fetus;
Palate;
Tomography;
Artificial intelligence
- From:
Chinese Journal of Ultrasonography
2023;32(3):227-233
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the feasibility of extracting the key plane of the normal fetal palate on the 11-13 + 6 week from tomography ultrasonography imaging based on artificial intelligence. Methods:The fetal volume datas of 235 cases of 11-13 + 6 week normal fetal were collected from the Department of Ultrasound in the Luohu District People′s Hospital of Shenzhen and Huazhong University of Science and Technology Union Shenzhen Hospital from May 2020 to April 2021. The data acquisition was completed by sonographers A and B by using the GE Voluson E10 color Doppler ultrasound diagnostic instrument. All datas were marked offline by sonographer C. Tomographic imaging was performed on all included data by sonographer D, the tomographic images were saved and the time-consuming was recorded, and the datas of the sonographer group were obtained. The labeled data were randomly divided into the training set and test set for model transfer learning and testing.The 4-fold cross-validation was adopted to record the test set image output by the model and the time consumption to obtain the intelligent group data. A senior sonographer performed image analysis on the two groups of data images. The feasibility of the intelligent model was verified by comparing the score of the plane of retronasal triangle(RTP), the acquisition rate of RTP, the acquisition rate of the fault, and the time-consuming difference between the sonographer group and the intelligent group. Results:①There was no significant difference in the overall distribution of RTP scores between the sonographer group and intelligent group [5 (5, 6) points vs 5 (5, 6) points, Z=0.355, P=0.722]. The RTP acquisition rate of the sonographer group and intelligent group was not statistically significant (78.72% vs 76.60%, χ 2=0.55, P=0.458). The consistency and correlation of RTP obtained by the two groups were high (Kappa=0.645, φ=0.646, both P<0.001). ②The effective layers of the sonographer group were 9 (8, 9) and the intelligent group was 8 (7, 9). The fault acquisition rate of the doctor group was higher than that of the intelligent group (78.72% vs 68.51%, χ 2=12.52, P=0.001). The consistency and correlation of the two groups in obtaining faults were media (Kappa=0.503, φ=0.521, both P<0.001). ③The time-consuming of the intelligent group was significantly lower than that of the sonographer group [1.50 (1.23, 1.75)s vs 26.94 (22.28, 30.48)s, Z=11.440, P<0.001]. Conclusions:This research model can quickly and accurately realize the extraction and tomography of the key plane of the normal fetal palate on the 11-13 + 6 week.